901008 • Pharma Pump Up Sprayer Pro, 1.5 Gallon
SAFETY & OPERATIONAL PRECAUTIONS
Manufacturer assumes no liability for the use or misuse of this unit.
Wear protective clothing, gloves and eye wear when working with chemicals.
Always direct the discharge away from electrical devices and people/animals (as appropriate)
Follow the chemical manufacturer's safe handling instructions.
SPECIAL PRECAUTIONS
This high density polyethylene unit is fitted with EPDM seals. Chemicals not compatible with polyethylene or EPDM should not be used. (Viton seals are available for separate
purchase.)
Do not alter pressure relief valve or plug valve hole.
Lubrication - Lubricant must be FDA and Site approved.
Regularly lubricate pressure relief valve with Dow Corning MOLYKOTE(R) 111 Compound and ensure proper operation, using water in the tank, prior to each use.
Regular lubrication of cap seal with Dow Corning MOLYKOTE(R) 111 Compound will help ensure proper sealing of cap.
Do not lift or carry by hose or trigger gun.
Securely tighten pump: loose pump can be forcibly ejected.
Carefully follow chemical manufacturer's safe handling instructions and recommended precautions/practices when using flammable chemicals. Do not use hot liquids.
Do not exceed 45 psi pressure and do not inflate without liquid in the tank
Do not fill the tank over 3/4 full. Relieving pressure in an overfill condition can cause harmful venting of contents.
Never stand with face or body over the top of tank when loosening pump or relieving pressure.
After pumping, be sure the handle is in the locked down position
On completion of operation, with the tank in the upright position, relieve pressure in the tank by gently pulling up on the pressure relief valve on the side of the tank.
TO INSTALL (REFER TO DIAGRAM ON NEXT PAGE)
1. Turn pump lid counterclockwise to remove pump and lid.
NOTE: Do not remove or tighten the lid using the handle. Rotational force on the handle can cause damage.
2. Add chemical solution to the tank. Leaving extra "air space" in the tank and less chemical will give longer spraying time between re-pressurizing. DO NOT FILL THE TANK
OVER 3/4 FULL (75%) .
3. Tighten cap and pump for a good seal. Regular lubrication of cap seal and threads will help ensure proper sealing and removal of cap.
NOTE: It is a good idea to thoroughly rinse out the tank, fill with water, partially re-pressurize, and discharge to flush out the entire hose/nozzle assembly after use
and before storing sprayer. When using aggressive or corrosive chemicals never leave chemical solution in the tank after use.
TO OPERATE
1. Pump up sprayer until the pressure relief valve starts to rise/relieve. Less if a lighter spray pressure and volume is desired
2. Pull the trigger to start and stop spraying. Re-pump up as spray begins to slow down.
3. On completion of spraying, with the tank in the upright position, relieve pressure in the tank by gently pulling up on the pressure relief valve on the side of the tank.
4. Prior to every refill of the tank, pull up on relief valve to ensure it is depressurized before removing the lid and pump.
5. To store: Partially fill the tank with fresh water and pump it up. Pull the trigger and rinse the sprayer out.
- Page 2 -