Download Print this page
jablotron JA-153E-GR Quick Start Manual

jablotron JA-153E-GR Quick Start Manual

Wireless access module with rfid and keypad

Advertisement

Quick Links

The JA-153E, JA-153E-GR, JA-153E-AN, JA-153E-WH
Wireless access module with RFID and keypad
The access module is a component of the JABLOTRON system.
Its modular architecture enables users to create a combination whose size of
installation perfectly meets their needs. The device should be installed by
a trained technician with a valid certificate issued by an authorised distributor.
The product is compatible with the JA-101Kx or higher control panels.
The wireless access module comprises the first control segment (1),
an RFID chip card / tag reader and keypad (4). The JA-192E, JA-192E-GR,
JA-192E-AN, JA-192E-WH segments can be used to extend the unit by
the required number of segments (the max. allowed amount is 20 on one unit).
The tilting keypad cover (6) can be removed if the user prefers permanent
access. It also works as an RFID card / tag reader.
Figure1: 1 – control segment;
2 – segment buttons; 3 – backlit activation button; 4 – access module with
RFID reader; 5 – tabs for module opening;
6 – cover screws
Installation
1.
Press the four tabs (5) on the sides (see figure 1) one by one and release
the module from the plastic base.
2.
When installing more control segments, first remove the socket cover on
the 1
segment.
st
3.
Remove the transparent plastic cover from the segments (by levering on
both sides of the segment near the buttons).
4.
Always connect the segment wires to the connector of the previous segment
and click them into each other (we recommend coiling the wires by turning
the segment by 360° - this will prevent any possible damage to the wires
between the plastic parts). Use this method to install all the required
segments. Finally push the socket cover in.
5.
Insert two 1.5 V alkaline AA batteries into the module.
6.
Attach the base onto the selected place together with the segments using
screws. If more segments are required fix those onto the wall using screws
as well (use the number of screws required).
7.
Connect the segment wires to the internal connector of the module (7).
8.
Insert the module into the base.
9.
Proceed according to the control panel installation manual.
Basic procedure:
a.
There must be a JA-110R radio module installed in the control panel
with a reliable communication range to the access module.
b.
When batteries are inserted, the yellow backlit activation button (3)
starts to light permanently which indicates that the module has not
been enrolled to the system yet.
c.
Go to the F-Link software, select the required position in
the Devices window and launch enrollment mode by clicking on
the Enroll option.
d.
Press the backlit activation button (3) – the module is thus enrolled
and the yellow LED indicator goes off (this can take a few sec).
An enrollment signal can also be sent by inserting the batteries.
10.
When you have completed installation, insert descriptive labels behind the
segment transparent covers and close them, see figure 3. Label printing is
a part of the F-Link software (Devices window, at the module position –
Internal settings).
Notes:
The module can also be enrolled to the system by entering its production
code (8) in the F-Link software or using a bar code scanner. All numbers stated
under the bar code shall be entered (1400-00-0000-0001).
To comply with the EN 50131-3 norm it is necessary to fix the cover tabs (5)
by the screws from the accessories. In picture no 1 the cover tabs are
displayed and marked by the arrows.
The JA-153E, JA-153E-GR, JA-153E-AN, JA-153E-WH
Figure 2: 7 – connector for control
segment; 8 – production code;
9 – terminals; 10 – mini USB
connector; 11 – batteries;
12 – tamper contact
1
ABCD...123
Figure 3: Insertion of a label into a control segment
Setting the properties
Go to the Devices window in the F-Link software. When you are at
the module position, use the Internal settings option. The particular unit is
displayed and it is possible to set its properties. Internal settings is separated into
2 basic tabs: Segments and Settings.
It is possible to set the required functions for individual segments (control of
sections, section status signalling, alarm triggering, PG output control, PG output
status signalling, etc.). More details are available in the F-Link software.
3
optional setting tab Common segment – settings and function description
rd
A common segment (up to 2 of them allowed on one keypad unit) simulates
the simultaneous pressing of several segments which are placed on this module
and which control sections. In the Segments tab select the specific segment
function called Common segment A (B). Then select the segments which will be
operated en bloc in the new tab Common segment.
Note: A module has to be equipped with a minimum of 3 segments otherwise this
function can not be used.
The selected sections will all be set / unset after pressing a button on the common
segment.
If the states of the segments which are operated by the common segment are
mixed, then only the segments that need changing will be set / unset.
If partial setting is enabled for some segments, then the common segment
respects this: 1
press = partially setting, 2
st
combine a common segment with a common section
The indication of the common segment is: all segments unset = green, some set
(partially set) = yellow, all sections fully set = red.
In the Settings tab you can set all other module functions like acoustic signalling,
backlight intensity, RFID reader mode, optical and acoustic indication, etc. Details
related to settings can be found in the installation manual of the control panel and of
course in the tooltips displayed by the F-Link software.
Battery Power save mode
The module saves its energy by shutting down the optical indication of system
status, module backlight and the RFID reader after 8 sec when the button, segment
or keypad cover have been pressed. The module still keeps communication with
the control panel and it can signal for example: an entrance delay. Complete waking
up is done when you press the cover of the module, or by pressing of any button.
Alternative power
The module can be powered from an external 12 V DC power supply via the
PWR and GND terminals. The DE 06-12 power supply can be used.
It has the advantage of hidden installation. The module does not enter battery
power mode if external power is used. It permanently communicates with
the control panel and it indicates the system status according to
the Devices / Internal settings. Leave the batteries inside the module.
When the mains power is cut off, the module will work from the batteries.
Connection of an external door detector
The module has an input terminal for external door detector connection.
The input (IN) reacts to disconnection from the common ground. The reaction
of this input is delayed and is linked to the module address. The input has
a status reaction.
1 / 2
2
3
4
press = full setting. It is not suitable to
nd
MLU51717

Advertisement

loading

Summary of Contents for jablotron JA-153E-GR

  • Page 1 The JA-153E, JA-153E-GR, JA-153E-AN, JA-153E-WH Wireless access module with RFID and keypad The access module is a component of the JABLOTRON system. Its modular architecture enables users to create a combination whose size of installation perfectly meets their needs. The device should be installed by a trained technician with a valid certificate issued by an authorised distributor.
  • Page 2 Note: For the best possible operation we strongly recommend using only expanded. In this case the new options are set to default. Check their batteries supplied by Jablotron’s authorized distribution (avoid usage of so called settings and adjust according to user requirements.

This manual is also suitable for:

Ja-153eJa-153e-anJa-153e-wh