Do you have a question about the IM10 and is the answer not in the manual?
Questions and answers
Summary of Contents for Imesa IM10
Page 1
E170203X 17/02/2017 IM10 SERVICE BOOK FOR TUMBLE DRYERS SERIES “T” FROM SERIAL NUMBER E201603001 FOR TANDEM SERIES: TDM FROM SERIAL NUMBER T201603001 FOR FLATWORK IRONERS FI SERIES FROM SERIAL NUMBER E201604011 IMESA S.p.A. Via degli Olmi 22 31040 Cessalto (TV), Italia tel.
CONTENT OF MANUAL ..................5 SAFETY RULES ..................... 5 MANUFACTURER LIABILITY ................6 IM10 MICROPROCESSOR FEATURES ..............7 SECTION “B” – WARNINGS AND TROUBLESHOOTING ..........7 SECTION “C” – USER MENU PARAMETERS ..............7 1) ACCESS TO USER MENU ..................... 7 2) SETTING .........................
Page 3
E170203X 17/02/2017 DEFAULT PROGRAMS ..................14 NEW PROGRAM ....................15 SECTION “D” – EXPERT MENU PARAMETERS ............. 17 1) ACCESS TO TECH MENU .................... 17 2) SETTINGS ........................18 MOTORS ......................18 ENERGY ......................18 PAYMENT SYSTEMS ..................20 RESIDUAL HUMIDITY ..................21 MODEM ........................
Page 4
E170203X 17/02/2017 FIRMWARE UPDATING ..................31 DO CALIBRATION TOUCH .................. 32 SAVE ALL ON USB ....................32 LOAD ALL FROM USB ..................33 REBOOT ......................33 REFLASH BOOT! ....................33 LOAD SYSTEM ICONS FROM USB ..............33 RESET THE APP PANNEL .................. 34 DEBUG MESSAGES ....................
1) CONTENT OF MANUAL Present manual contains all useful information for a correct using of controls available on IMESA tumble dryers “T” series. It is written in compliance with the European Community rules in force. The information here written is addressed to the service provider who must be sure to fully understand them before use of the machine.
Periodical and/or programmed maintenance is missing; Manual instructions were not respected; Defects occur in the power supply; Non authorized modifications made on the machine; Non-authorized personnel use the machine; Wrong connection to IM10 control board SOMMARIO...
SECTION “C” – USER MENU PARAMETERS 1) ACCESS TO USER MENU The user menu contains all functions and monitoring of the IM10 logic board. The menu access is available as follow: Standard setting (not self-service): touch the symbol “⋮” on top right and digit password “123456”.
“Ѵ” lights up. 2) SETTING 1. CHOOSE LANGUAGE Select a language. Dictionary of different languages must be present on the IM10 board. 2. DATA SETTING Set the date of the system. This function is available on the following path :\USER\SETTING\DATA SETTING.
Password must be entered and reconfirmed. IM10 requires a different password on each ambient (technical area, the user area, factory default settings, etc.). In the case of a duplicate, IM10 intervenes and block it obliging to insert a different password.
“Ѵ” to confirm the icon selected 12. ICONS UPLOADING FROM USB Programs icons are images appearing on the screen when selecting the program. IMESA uploads by default around twenty and the customer can assign them to the program using procedure SCREEN LAYOUT HANDLING.
NOTE: icons can be added anytime: that is there is the possibility to upload an icon at the time, without cancelling the ones already stored. Attention: if an icon is uploaded with the same name of an icon already present on IM10, it will be overwritten.
E170203X 17/02/2017 available font) “MACHINE NR. Xx” where “xx” corresponds to a number on the central cash. This parameter must be available in the only event the machine is set on “CENTRAL CASH”. THE NUMBER IS PRESENT ON THE SETTING BUT THE NUMBER IS NEVER SHOWN. 14.
E170203X 17/02/2017 TO DOWNLOAD THE .txt FILE Enter the menu USER\RECORDINGS\RECORDINGS DOWNLOAD On display INSERT USB DEVICE All data automatically uploads on the USB once inserted creating a “.txt” file. It takes few seconds. At the end, the display shows RECORDINGS OK. Push OK.
E170203X 17/02/2017 4) PROGRAMS 1. SINGLE CYCLE This function is available on the following path :\USER\PROGRAMS\SINGLE CYCLE. Enter the technical password (159357) to accede on SINGLE CYCLE where it is possible to modify default value of time (5’) and of temperature (50°C). Selecting SINGLE CYCLE from the starting screen, it will start an instantaneous program where (starting from default value) the user can set (and change during the running cycle) time and temperature values.
Page 15
E170203X 17/02/2017 - Counterclockwise rotation: 40 seconds Rotation and pause times can be reprogrammed (see relevant paragraph). On machines equipped with related options, the others default values are the same for all programs: Heating power: level 3; Drum speed: 40 rpm; Fun speed: speed 2 Enter the programming area to modify features of stored by default programs or to add new ones.
Page 16
E170203X 17/02/2017 (excepting hysteresis). PROGRAM TYPE: selecting this parameter the program runs in an automatic mode (at the end of the cycle, residual humidity level must be set) or in standard mode (defining cycle length): o AUTOMATIC with residual humidity (heating with HEATING PUMP is available and selectable only if cycle is a FAST type).
Page 17
SECTION “D” – EXPERT MENU PARAMETERS 1) ACCESS TO TECH MENU Tech menu contains all functional parameters of the IM10 logic board. Here follow the path to access: On standard configuration (excepting for self-service): Touch symbol “⋮” on top right and digit password “159357”.
Page 18
E170203X 17/02/2017 2) SETTINGS 1. MOTORS REVERSING DRUM: o PRESENT o ABSENT REVERSING DRUM PRESENT allows defining the “rhythm” of drum rotation individually on each program. See the menu “:\USER\PROGRAMS\PROGRAM n”, changing following parameters: o DRUM FORWARD: TIME o DRUM PAUSE: TIME o DRUM BACKWARD: TIME FAN INVERTER: this parameter allows the inverter adjusting fan speed control.
Page 19
STOP COMPENSATION: when this parameter is ON during GREEN cycle the IM10 independently extends the cycle duration for the corresponding time compressors were stopped due to a pause or to the opening of filter/door. This is not valid in the case of a power failure.
Page 20
E170203X 17/02/2017 INSTALLED POWER: the user can fill in the value of installed power as per machine setting. Enter on the menu: \USER\RECORDINGS\ENERGY STATS machine consumption can be monitored. Stats data will be available only if the installer correctly sets following parameters: o DRUM MOTOR POWER o FAN MOTOR POWER (Kw)
Page 21
E170203X 17/02/2017 MONETARY UNIT: machines with payment system have 5 standard currency symbols available to define a credit plus 1 extra to create your own, as per paragraph above. o € o £ o COINS o RM INPUT VALUE COIN 1: when mechanical coin box, this parameter allows the definition of one coin value showed on currency chosen by MONETARY UNIT.
Page 22
E170203X 17/02/2017 Function DRY, example: N° INTERVENTIONS = 1 HYSTERESIS = 5°C COOL DOWN DELAY= 10’ Function EXTRA DRY example: o N° INTERVENTIONS = 3 o HYSTERESIS = 5°C o COOL DOWN DELAY = 0’ MODEM Tumble dryer can be equipped with GSM module. ACTIVATION / DEACTIVATION: ABSENT PRESENT...
Page 23
E170203X 17/02/2017 GREEN LIGHT buttons are active Not used ACCEPT BUTTON KEY SWITCH enable the remote control ATTENTION, the picture is purely indicative, but not buttons role. 7. NUMBERS OF PROGRAMS TO SHOW This function can set how many programs we want to show on the menu. The menu can show only the same number of programs stored.
Page 24
E170203X 17/02/2017 on outputs display that shows four blue coloured frames to access for relevant tests as: FAN AND PRESSURE TEST HEATING TEST 1: the display shows two different views following HEATING TECHNOLOGY used: o ELECTRIC OR STEAM heating: HEATING TEST 1 display shows on top a blue button with the name of the test (HEATING TEST 1).
Page 25
E170203X 17/02/2017 ANTI-FIRE PROTECTION acoustic alarm. Under the status frame there is another blue one showing TEMPERATURE PROBE reading data: ..°C. just under, there is a green button START. Pushing START, the exit is activated and the second contactors resistors functionally can be checked (when the machine is equipped with power level control).
Page 26
To enter the password there are two phases in two different screens because password must be entered and then, confirmed. IM10 microprocessor checks this password and if doubled, it stops it. Every password must be different from the others (technical area, the user area, and factory).
Page 27
When the download is ended, the display shows “UPLOADING FROM USB OK” and pushing icon OK on the bottom center side, the IM10 microprocessor restarts using new parameters. The machine asks for LANGUAGE, DATE and TIME.
Page 28
\USER\SETTINGS\CHANGE LANGUAGE. Upload the dictionary on a USB key from the TECHNICAL menu, “PASSWORD/INITIALIZATIONS”. A xlsm file called lingue_IM10. is filled with all words, convert into txt file using “CREATE LANGUAGE”: IM10 microprocessor can work with a text file .txt format. SOMMARIO...
Page 29
40”. At the end, it is displayed “LOADING OK”. Push OK: IM10 turns off and on by itself. Without pushing OK within 10 secs, the IM10 turns off and on by itself. 11. SCREEN SAVER FILE UPLOADING FROM USB The image called “First” is the one showed during the start of the machine.
Page 30
Click on OK. The display shows: . Click OK. Images dedicated to IM10 are now available on folder “screen” extension “.IM10ico” inside the original folder. Add a folder named “IM10_DATA” on the USB key. NOTE: key must be format 2FAT32”: Cut &...
Page 31
At the end, “UPLOADING OK” is displayed. Push OK: IM10 turns off and on by itself. Without pushing OK within 10 secs, the IM10 turns off and on by itself. NOTE: the view of screen savers are regulated by following parameters: :\TECHNICAL\SETTINGS\TIME REFRESH SCREEN SAVER;...
Page 32
14. DO CALIBRATION TOUCH It allows touch screen calibration. Entering on that menu, IM10 shows cursor position as a cross; using a touch screen pen (recommended) move the cursor around the display to check if the cursor follows correctly the touch screen pen. In any case, calibration menu suggests: “...
Page 33
“UPDATING, WAIT …” and on the lowest side, it shows parameters during uploading. When the IM10 parameters download is ended, the display shows “UPLOADING FROM USB OK” and pushing icon OK on the bottom center side, the IM10 restarts using new parameters. 17. REBOOT This parameter lets execute the system boot sequence, without turning off and on the machine.
Page 34
“UPLOADING SYSTEM ICONS OK” and pushing OK the system is restarted with new icons. NOTE: at the end of the loading, even without pushing restart, IM10 will automatically turn off and on by itself after 30”. 20. RESET THE APP PANNEL This function allows cancelling programs representative icons, restoring the IM10 default base –icons.
Need help?
Do you have a question about the IM10 and is the answer not in the manual?
Questions and answers