Operation Manual 12./07 WISI Communications GmbH & Co. KG Index SAFETY AND INSTALLATION NOTES PLEASE OBSERVE! ..... I 1. Overview 1.1 System Introduction 1.2 Function Introduction 1.3 Front & rear panel 2. Basic configuration of the device 2.1 Configuring a brand new device 2.2 Using the scrcmd tool to configure the IP address...
Operation Manual 12./07 WISI Communications GmbH & Co. KG SAFETY AND INSTALLATION NOTES PLEASE OBSERVE! Caution The mains voltage must match the rated input voltage of the unit (180-265 VAC; 50/60 Hz). Connecting cable — Lay the cable so that no- one can trip over it.
1. Overview 1.1 System Introduction OT 32 Scrambler is the equipment that scrambles selected programs of transport stream (TS) under the control of CAS, allows the only authorized user to receive and watch the programs. Thereby system operator can realize management of conditional charge.
Operation Manual 12./07 WISI Communications GmbH & Co. KG 1.3 Front and rear panel WISI STREAMLINE Scrambler STATUS STATUS POWER FUSE T2A/250 VAC trough out 1 out 2 trough out 1 out 2 Ethernet Ethernet 230 VAC Figure 2-1 Stand-alone scrambler back panel interface...
Operation Manual 12./07 WISI Communications GmbH & Co. KG 2. Basic configuration of the device For general every day administrative purposes the device supports: • HTML web browser interface For configuration of a brand new device a proprietary interface called “BCMD” = “broadcast command”...
Page 7
Operation Manual 12./07 WISI Communications GmbH & Co. KG The command reconfigures the IP address of the scrambler identified by the MAC address 00:11[...] to 172.29.0.130. scrcmd -mac=00:11:22:33:44:55 -ip=172.29.0.130 -mask=255.255.0.0 –reboot Identify the physical scrambler visually by its MAC address The command causes the scrambler owning the MAC address 00:11[...] to flash its front panel...
Operation Manual 12./07 WISI Communications GmbH & Co. KG 3. Scrambling configuration (web browser interface) The HTTP Interface consists of a menu frame on the left hand side and a parameter frame on the right hand side. To open the HTML interface, open a web browser and enter the URL (replace 172.29.0.130 by the IP address of your device): http://172.29.0.130...
Operation Manual 12./07 WISI Communications GmbH & Co. KG To make modifications to settings, click into the corresponding edit box, alter the value and then click on the “Submit” button located on the upper left corner of the HTML page. The scrambler will then process the modifications.
Operation Manual 12./07 WISI Communications GmbH & Co. KG 3.2 Status Page The Status page is the index page of the HTML interface. It will automatically show if you access the scrambler, or if you click on Status in the menu bar on the left hand side. This page shows version numbers and an overall description of the scrambler status.
Operation Manual 12./07 WISI Communications GmbH & Co. KG 3.3 Detailed Event Log The detailed event log is accessed by clicking on “Status” in the menu bar on the left hand side and then on the link “Detailed Event Log”. The “Event log” is a table, storing: ·...
Operation Manual 12./07 WISI Communications GmbH & Co. KG 3.5 ASI I/O Status Page The ASI I/O Status Pages shows the status of the ASI input and output. The content will be updated when you press “Refresh”. • Input data rate: Detected data rate on the ASI input.
Operation Manual 12./07 WISI Communications GmbH & Co. KG • Output null packet rate: Number of null packets generated by the scrambler per second to meet the output data rate. • Output data rate: The data rate being output on the ASI.
Operation Manual 12./07 WISI Communications GmbH & Co. KG 1 should only be used for debugging purposes of course! • 48Bit CW: If 0, the scrambler will use 64 Bit codewords to scramble the content. If 1 (nonzero), the scrambler will use 48Bit codewords. Some CAS only support the 48Bit mode.
Operation Manual 12./07 WISI Communications GmbH & Co. KG 3.8 ECMG Status Page The ECMG Status Page consists of two parts. The upper part lets you verify the connection and communication between ECMG and the scrambler. Use the scrollbar of your browser to reach the bottom part of the ECMG Status. The bottom part informs you about the DVB SimulCrypt parameters that the scrambler and ECMG agreed on using.
Operation Manual 12./07 WISI Communications GmbH & Co. KG The example shows a configuration, that lets the scrambler listen on port TCP port 5001 for EMMG requests, like EMM provisions. It will also accept EMM provisions on UDP port 2003.
Operation Manual 12./07 WISI Communications GmbH & Co. KG 3.11 EIS Settings Page The EIS is an (external) software component that defines Scrambling Control Groups. It connects to the scrambler using TCP/IP. The scrambler will listen on the specific port for message of the EIS.
Operation Manual 12./07 WISI Communications GmbH & Co. KG It is possible to verify the Scrambling Control Groups that were defined by an EIS, by clicking on “Scrambling” in the menu bar. 3.12 Detailed EIS Status Page The EIS status page lets you check the communication between the EIS and the scrambler.
Operation Manual 12./07 WISI Communications GmbH & Co. KG The content of the CA descriptors of the CAT will change immediately (within 500ms). The contents of the CA descriptors in a PMT will only change when the corresponding services switches from clear to scrambled. If you use Save&Reboot after the whole setup, you can be sure, that your private data will be used.
Page 20
Operation Manual 12./07 WISI Communications GmbH & Co. KG To scan for services, click on the “Scan” button. During scan the page looks like below. If the web browser supports timed updates, the page will be update automatically every 5 seconds and notify you about the scanning progress.
Page 21
Operation Manual 12./07 WISI Communications GmbH & Co. KG The link “here” will lead you to the “Detailed Event Log” which contains some more detailed information about the reason of the failure. If everything works well the scrambler will present a list of services like shown in the example below.
Operation Manual 12./07 WISI Communications GmbH & Co. KG 3.17 Scrambling Control Group List A Scrambling Control Group (SCG) is a bundle of services to be scrambled at the same time using the same codeword and the same access criteria for specific ECMG.
Page 23
Operation Manual 12./07 WISI Communications GmbH & Co. KG The Scrambling Control Group (SCG) lists consists of 6 columns. • SCG-ID: This is the ID of the Scrambling Control Group. Its an unique number identifying the SCG. You may manually define this value on the “Edit (new) SCG Page”.
Operation Manual 12./07 WISI Communications GmbH & Co. KG • Clr: This is an abbreviation for “clear”. If you click on this link, the scrambler will schedule a deprovision of all services scrambled by this SCG. This means, that all services will as soon as possible become free-to-air (clear / not scrambled).
Page 25
Operation Manual 12./07 WISI Communications GmbH & Co. KG The parameters in the upper part are: • Name: This is a string of characters. It is just used as a mnemonic to identify the Scrambling Control Group for the administrator.
Operation Manual 12./07 WISI Communications GmbH & Co. KG possible to have the video component of a service in an SCG with ID “0x0001” while the audio components of the same service are part of an SCG with ID “0x0002” (another SCG).
Operation Manual 12./07 WISI Communications GmbH & Co. KG Of course, you may also mix an access criteria and scrambling state change. 3.21 Deprovision of an existing Scrambling Control Group Deprovision means, that all services of a Scrambling Control Group will become free-to-air services.
Operation Manual 12./07 WISI Communications GmbH & Co. KG Note: Do not turn off power, while the LED´s indicate RED. If you turn off power during the flash process,your current settings will be lost and the scrambler will use default settings after the reboot.
Page 29
Operation Manual 12./07 WISI Communications GmbH & Co. KG Click on the button, to destroy all temporary unsaved changes and reboot the scrambler using the settings currently stored in the flash memory. All changes made since the last reboot will be lost.
Operation Manual 12./07 WISI Communications GmbH & Co. KG 4. Specifications ASI – receiver (input) ASI – receiver (input) Data format DVB A010 ASI-C, EN50083-0 Packet framing 188 / 204 byte per packet Bitrate 270 Mbps ASI mode Burst or Continous...
Page 31
Operation Manual 12./07 WISI Communications GmbH & Co. KG 12,0 V (± 8%) 500 mA DC max. Power consumption … Operating temperatur range 5°C to 45°C Nominal temperatur range 15°C to 35°C Page 30 of 32...
Page 32
Empfangs- und Verteiltechnik P.O. BOX 1220, 75219 Niefern-Oeschelbronn, Germany Phone +49 7233 66 280, Fax - 66 350, http://www.wisi.de ... a link to the future Technical Modifications reserved. WISI cannot be held liable for any printing error Page 31 of 32...