INSTALLATION, OPERATION
& SERVICE INSTRUCTIONS
Why home dehumidification is important. At CADPXS we
believe Healthy Air is essential– especially inyour
home.

Advertisement

Table of Contents
loading

Summary of Contents for CADPXS FEONIXS

  • Page 1 INSTALLATION, OPERATION & SERVICE INSTRUCTIONS Why home dehumidification is important. At CADPXS we believe Healthy Air is essential– especially inyour home.
  • Page 2 TABE OF CONTENTS...
  • Page 3 • It is designed to be used INDOORS ONLY. • If used in a wet area, plug it into a GROUND FAULT INTERRUPTER. • DO NOT use the FEONIXS as a bench or table. • It must always be used in the upright position.
  • Page 4: Electrical Supply

    INTRODUCTION FEONIXS is a highly power dehumidifier created by a company dedicated to achieving maximum humidity in an ultra-space-saving design. These machines deliver optimum results even in the toughest water restoration environments. With Low Energy input and is very lightweight. It excels in delivering high-performance results of 85 Pints per Day.
  • Page 5: Operation

    INSTALLATION AND OPERATION GUIDE Selecting the Location • Place the Unit in an Upright Position. • The location of the operation should be an enclosed area. • The location should allow constant air circulation. • The location should have power outlet at about 6 meters of the device as that is the length of the cord.
  • Page 6 Press the SET button to scroll through available values. STARTUP 1.When the unit is plugged in you will see the CADPXS LOGO. 2.The display will inform the machine is in shutdown mode, press the “Power button” to turn on.
  • Page 7 4. 1 P r es s t h e M E N U b u t t o n t o en t er t h e s u b m e n u . D e v i c e n a m e d i s p l a ye d o n t h e s c r e e n .
  • Page 8 4 . 6 P r e s s t h e S e t b u t t o n t o t o g g l e t h e temperature units between . Press the MENU button to confirm selection and advance to the next screen.
  • Page 9: Troubleshooting

    5.1 When the purge button is pressed the display will tell the user on the dashboard that the pump is draining and display a 30-second countdown timer. Until the machine finishes draining, the display will also prompt the user on the dashboard that the machine is draining a u t o m a t i c a l l y, a n d d i s p l a y a 3 0 - s e c o n d countdown.
  • Page 10: Maintenance

    Wi-Fi connection successful. Connection to server failed. Hotspot direct successful icon. MAINTENANCE Unit Maintenance • Always clean the surface of the housing with a damp cloth. Do not clean with water directly. • Always store the machine in a day and cool indoor place, away from sunlight as well as chemicals and out of children’s reach.
  • Page 11: Wiring Diagram

    WIRING DIAGRAM FLOAT SWITCH (LOW) BLOWER CAPACITOR BLOWER SWITCHING POWER PUMP SUPPLY(DC) VALUE (24v) V+ V- L N TEMP/RH SENSOR DRAIN TRANSFORMER COMP EVAP THERMISTOR PROBE POWER BOARD COMPRESSOR TEMP/RH CAPACITOR SENSOR CONTROL BOARD...
  • Page 12: Warranty Registration

    WARRANTY REGISTRATION CADPXS believes in the quality of its products. This is why it stands behind its products and gives a more extended warranty than what you can get elsewhere. To CADPXS, a longer warranty is an important aspect of our service.
  • Page 13 2550 N LOOP FWY #108 HOUSTON TX 77092 (888)928-1380 888-888-8888 888-888-8888 888-888-8888 (Monday-Friday: 08:00AM – 5:00PM) PDT (Monday-Friday: 08:00AM – 5:00PM) PDT (Monday-Friday: 08:00AM – 5:00PM) PDT (Monday-Friday: 08:00AM – 5:00PM) UTC support@cadpxs.com support@cadpxs.com support@cadpxs.com support@cadpxs.com www.cadpxs.com www.cadpxs.com www.cadpxs.com www.cadpxs.com...