barbas 90-60 PF2 Preparation Manual

Hide thumbs Also See for 90-60 PF2:
Table of Contents

Advertisement

Quick Links

Preparation manual
Gas Fire Front 90-60 PF2
---- Floating Frame --------------- Floating Frame + ----
---- Hidden Door --------------------- Hidden Door + ----
Serial number:
Production date:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 90-60 PF2 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for barbas 90-60 PF2

  • Page 1 Preparation manual Gas Fire Front 90-60 PF2 ---- Floating Frame --------------- Floating Frame + ---- ---- Hidden Door --------------------- Hidden Door + ---- Serial number: Production date:...
  • Page 2 Barbas Bellfires BV.This document could contain technical inaccuracies or typographical errors. Barbas Bellfires BV reserves the right to revise this document from time to time in thecontents thereof.
  • Page 3: Table Of Contents

    Gas Fire Front 90-60 PF2 with Floating Frame................. 22 Gas Fire Front 90-60 PF2 with Floating Frame +..............23 Gas Fire Front 90-60 PF2 with Floating Frame and adjustable legs......... 24 Gas Fire Front 90-60 PF2 with Hidden Door................25 Gas Fire Front 90-60 PF2 with Hidden Door +................
  • Page 4: About This Document

    • Preparation for installation This document refers to the Gas Fire Front 90-60 PF2 as 'the appliance'. This document is an essential part of your appliance.Read it carefully before you do work on the appliance. Keep it in a safe place.
  • Page 5: Overview Of The Concentric Flue System

    Overview of the concentric flue system Overview of the concentric flue system The concentric flue system provides the appliance with combustion air and removes the flue gases from the appliance. The concentric flue system is made of these items: Item Description The concentric flue is a pipe with an inner pipe.
  • Page 6: Safety

    - Part 1: System chimney products ). Concerns building materials according to DIN 18160 Chimney systems. For installation and use of the Opti-Vent system refer to the Barbas manual "installation and mainte- nance manual Opti-Vent system. Gas Fire Front 90-60...
  • Page 7: Requirements

    Requirements Requirements Requirements on the location • Never use combustible building materials for the fireplace. • Do not install the appliance against a flammable rear wall. • Install a non-flammable insulation plate of at least 12 mm between the appliance and a non-flammable rear wall.
  • Page 8: Requirements On The Roof And Wall Outlet

    Requirements Requirements on the roof and wall outlet Location of roof and wall outlets Refer to the table hereunder for explanation of the figure. Note: All the minimum distances in the table are guidelines. Consult your national and local regulations for the exact minimum distances. Gas Fire Front 90-60...
  • Page 9 Requirements Minimum separation distances for roof and wall outlet(terminal) in mm Minimum Location distance [mm] Below an opening on the same wall/roof 2000 Above an opening on the same wall/roof Horizontally to an opening on the same wall/roof Horizontally to a facing opening in a opposite wall 2000 From a roof terminal under an opening...
  • Page 10: Requirements On The Concentric Flue System

    Requirements Requirements on the concentric flue system Caution: • Make sure that no flammable materials are located close to the flue system. The outer walls of the flue system can be 150 °C. • Make sure that the concentric flue system is in a casing. •...
  • Page 11: Possibilities For A Concentric Flue System With A Roof Outlet

    Requirements   4.5.1 Possibilities for a concentric flue system with a roof outlet Rigid concentric flue systems Note: Refer to chapter for a description of the numbers in the figures. 10/11/12/13 4,28,(100) Concentric flue connection on appliance Ø100-Ø150 mm or Ø130-Ø200 mm Flue gas restriction plate width Concentric connection on the appli- Concentric connection on the appli-...
  • Page 12 Requirements   14,15 10/11/12/13 4,28,(100) Concentric flue connection on appliance Ø100-Ø150 mm or Ø130-Ø200 mm Flue gas restriction plate width Concentric connection Concentric connection (min. - max.) (min. - max.) (min. - max.) on the appliance is on the appliance is Ø100-Ø150 mm Ø130-Ø200 mm 1.0 - 11.0 m...
  • Page 13 Requirements   Flexible concentric flue systems 10/11/12/13 4,28,(100) Concentric flue connection on appliance Ø100-Ø150 mm or Ø130-Ø200 mm Flue gas restriction plate width Concentric connection on the appli- Concentric connection on the appli- (min. - max.) ance is Ø100-Ø150 mm ance is Ø130-Ø200 mm 2.0 - 4.0 m 30 mm...
  • Page 14 Requirements   ≥45° 10/11/12/13 4,28,(100) Concentric flue connection on appliance Ø100-Ø150 mm or Ø130-Ø200 mm Flue gas restriction plate width Concentric connection Concentric connection (min. - max.) (min. - max.) (min. - max.) on the appliance is on the appliance is Ø100-Ø150 mm Ø130-Ø200 mm 1.0 - 11.0 m...
  • Page 15 Requirements   27,28,29 26,29 4,28,(100) Concentric flue connection on appliance Ø100-Ø150 mm or Ø130-Ø200 mm Flue gas restriction plate width Concentric connection on the appli- Concentric connection on the appli- (min. - max.) ance is Ø100-Ø150 mm ance is Ø130-Ø200 mm 2.0 - 4.0 m 30 mm 65 mm...
  • Page 16 Requirements   ≥45° 27,28,29 26,29 4,28,(100) Concentric flue connection on appliance Ø100-Ø150 mm or Ø130-Ø200 mm Flue gas restriction plate width Concentric connection Concentric connection (min. - max.) (min. - max.) (min. - max.) on the appliance is on the appliance is Ø100-Ø150 mm Ø130-Ø200 mm 1.0 - 11.0 m...
  • Page 17: Possibilities For A Concentric Flue System With A Wall Outlet

    Requirements   4.5.2 Possibilities for a concentric flue system with a wall outlet Note: Refer to chapter for a description of the numbers in the figures. Install the wall outlet in the correct position as shown in the figure. The centre of the inner pipe must be positioned above the centre of the outer pipe.
  • Page 18 Requirements   0.16 m 110/111/113 4,128 Concentric flue connection on appliance Ø130-Ø200 mm Flue gas restriction plate width Concentric connection on the appliance (min. - max.) (min. - max.) is Ø130-Ø200 mm 0.5 - 1.0 m 0 - 0.6 m 1.0 - 2.0 m 0 - 2.6 m Gas Fire Front 90-60...
  • Page 19 Requirements   0.25 m 110/111/113 4,128 Concentric flue connection on appliance Ø130-Ø200 mm Flue gas restriction plate width Concentric connection on the appliance (min. - max.) (min. - max.) is Ø130-Ø200 mm 0.5 - 1.0 m 0 - 1.6 m 1.0 - 3.0 m 0 - 4.6 m Gas Fire Front 90-60...
  • Page 20 Requirements   0.16 m 110/111/ 110/113 110/111/113 4,128 Concentric flue connection on appliance Ø130-Ø200 mm Flue gas restriction plate width Concentric connection on (min. - max.) (min. - max.) (min. - max.) (min. - max.) the appliance is Ø130- Ø200 mm 0 - 0.5 m 0 - 0.5 m 0.5 - 1.0 m...
  • Page 21 Requirements   0.25 m 110/111/113 4,128 Concentric flue connection on appliance Ø130-Ø200 mm Flue gas restriction plate width Concentric connection on the appliance (min. - max.) (min. - max.) is Ø130-Ø200 mm 0 - 0.5 m 0 - 0.6 m 0.5 - 1.0 m 0 - 3.6 m 1.0 - 3.0 m...
  • Page 22: Technical Specification

    Technical specification Technical specification Gas Fire Front 90-60 PF2 with Floating Frame * = Gas connection Gas Fire Front 90-60...
  • Page 23: Gas Fire Front 90-60 Pf2 With Floating Frame

    Technical specification Gas Fire Front 90-60 PF2 with Floating Frame + * = Gas connection Gas Fire Front 90-60...
  • Page 24: Gas Fire Front 90-60 Pf2 With Floating Frame And Adjustable Legs

    Technical specification Gas Fire Front 90-60 PF2 with Floating Frame and adjustable legs With optional adjustable legs * = Gas connection ** = Maximum height with adjustable legs Gas Fire Front 90-60...
  • Page 25: Gas Fire Front 90-60 Pf2 With Hidden Door

    Technical specification Gas Fire Front 90-60 PF2 with Hidden Door * = Gas connection Gas Fire Front 90-60...
  • Page 26: Gas Fire Front 90-60 Pf2 With Hidden Door

    Technical specification Gas Fire Front 90-60 PF2 with Hidden Door + * = Gas connection Gas Fire Front 90-60...
  • Page 27: Gas Fire Front 90-60 Pf2 With Hidden Door And Adjustable Legs

    Technical specification Gas Fire Front 90-60 PF2 with Hidden Door and adjustable legs With optional adjustable legs * = Gas connection ** = Maximum height with adjustable legs Gas Fire Front 90-60...
  • Page 28: Gas Fire Front 90-60 Pf2 With Hidden Door And Convection Casing

    Technical specification Gas Fire Front 90-60 PF2 with Hidden Door and convection casing With optional convection case * = Gas connection Gas Fire Front 90-60...
  • Page 29: Gas Fire Front 90-60 Pf2 With Floating Frame + And Convection Casing

    Technical specification Gas Fire Front 90-60 PF2 with Floating Frame + and convection casing With optional convection case Gas Fire Front 90-60...
  • Page 30: Dimensions Of The Restriction Plate

    Technical specification Dimensions of the restriction plate Width of the delivered flue restriction plates in mm Concentric flue connection Ø100 - Ø150 Concentric flue connection Ø130 - Ø200 Roof-mounted outlet Horizontal wall outlet 30 mm 40 mm 40 mm 50 mm 50 mm 65 mm 65 mm...
  • Page 31: Available Components For The Concentric Flue System - Natural Draught

    Available components for the concentric flue system - natural draught Available components for the concentric flue system - natural draught Caution: Observe the installation instructions that are supplied with the components of the concentric flue system. The appliance with extraction of the flue gasses by natural draught, in combination with the concentric flue system [Ø100 mm - Ø150 mm] and/or [Ø130 mm - Ø200 mm] (rigid and/or flexible) for the brand types mentioned below, has been approvedin accordance with the European CE-norm for gas appliances and may therefore beused only with these...
  • Page 32: Bellfires - Muelink & Grol System Ø100 - Ø150

    Available components for the concentric flue system - natural draught Bellfires - Muelink & Grol system Ø100 - Ø150 Color (*) Application Bellfires Fig. Art./ Order Description stainless antr. rigid flex steel Twin-wall balanced flue 302289 ● ● pipe. L= 500 mm. Twin-wall balanced flue 346236 pipe.
  • Page 33 Available components for the concentric flue system - natural draught Color (*) Application Bellfires Fig. Art./ Order Description stainless antr. rigid flex steel Twin-wall balanced flue 302297 ● ● elbow 90°. (ribbed) Twin-wall balanced flue 346239 elbow 90°. (segment) ● ●...
  • Page 34 Available components for the concentric flue system - natural draught Color (*) Application Bellfires Fig. Art./ Order Description stainless antr. rigid flex steel Vertical (roof) termina- 302295 tion kit, L= 1360 mm. ● ● ● ● ANTHRACITE Adjustable roof flash- 302212 ing.
  • Page 35 Available components for the concentric flue system - natural draught Color (*) Application Bellfires Fig. Art./ Order Description stainless antr. rigid flex steel 302215 Wall strap. ● ● ● Set of ceiling finishing 302214 ● ● ● plates / Fire stops. Ceiling plate for transi- tion Ø100 mm / Ø150 302189...
  • Page 36 Available components for the concentric flue system - natural draught Color (*) Application Bellfires Fig. Art./ Order Description stainless antr. rigid flex steel Hose clamp Ø150 mm. 304042 (Minimum 2 per con- ● ● nection) Vertical (roof) termina- tion kit, L = 610 mm. 302307 Suitable for a flexible ●...
  • Page 37 Available components for the concentric flue system - natural draught used to extractthe flue gasses. The temperature classification of the flexible pipe must be at least T450. Gas Fire Front 90-60...
  • Page 38: Bellfires - Muelink & Grol System Ø130 - Ø200

    Available components for the concentric flue system - natural draught Bellfires - Muelink & Grol system Ø130 - Ø200 Color (*) Application Bellfires Fig. Art./ Order Description stainless antr. rigid flex steel Concentric reduc- tion of Ø130 / 302319 ● ●...
  • Page 39 Available components for the concentric flue system - natural draught Color (*) Application Bellfires Fig. Art./ Order Description stainless antr. rigid flex steel Twin-wall balanced 302314 flue elbow 90°. (rib- ● ● bed) Twin-wall balanced 302315 flue elbow 45°. (rib- ●...
  • Page 40 Available components for the concentric flue system - natural draught Color (*) Application Bellfires Fig. Art./ Order Description stainless antr. rigid flex steel Silicone seal Ø200 302248 ● ● 302251 Wall strap. ● ● Set of ceiling fin- 302250 ishing plates / Fire ●...
  • Page 41 Available components for the concentric flue system - natural draught Color (*) Application Bellfires Fig. Art./ Order Description stainless antr. rigid flex steel Hose clamp Ø130 304045 mm. (Minimum 2 ● ● per connection). Hose clamp Ø200 304046 mm. (Minimum 2 ●...
  • Page 42: Poujoulat - Duogas System Ø100 - Ø150

    Available components for the concentric flue system - natural draught Poujoulat - DUOGAS system Ø100 - Ø150 Poujoulat Art./ Order Description 34100403 Twin-wall balanced flue pipe, L= 250 mm. 34100404 Twin-wall balanced flue pipe. L= 450 mm. 34100405 Twin-wall balanced flue pipe. L= 950 mm. Telescopic twin-wall balanced flue pipe, L= min.
  • Page 43 Available components for the concentric flue system - natural draught Poujoulat Art./ Order Description 34100654 Vertical (roof) termination kit, L= 140 mm . Roof flashing, suitable for a brick roof, with a roof pitch 45150171 of 15°- 30°. Roof flashing, suitable for a tiled roof, with a roof pitch 45150170 of 15°- 30°.
  • Page 44 Available components for the concentric flue system - natural draught Poujoulat Art./ Order Description 37100442 Ceiling/wall plate with spacers and ventilation grooves. Set of ceiling finishing plates / Fire stops,suitable for a 37100425 roof pitch of 0°- 10°. Set of ceiling finishing plates / Fire stops,suitable for a 37100426 roof pitch of 10°- 30°.
  • Page 45: Poujoulat - Duogas System Ø130 - Ø200

    Available components for the concentric flue system - natural draught Poujoulat - DUOGAS system Ø130 - Ø200 Poujoulat Art./ Order Description 34130403 Twin-wall balanced flue pipe, L= 250 mm. 34130404 Twin-wall balanced flue pipe. L= 450 mm. 34130405 Twin-wall balanced flue pipe. L= 950 mm. Telescopic twin-wall balanced flue pipe, L= min.
  • Page 46 Available components for the concentric flue system - natural draught Poujoulat Art./ Order Description Horizontal (wall) termination kit, L= min. 365 mm / max. 34130610 585 mm. 45200076 Stainless steel locking band Ø200 mm, quick-fastening. 45200072 Wall strap, Ø200 mm. 37130442 Ceiling/wall plate with spacers and ventilation grooves.
  • Page 47: Ontop - Metaloterm Us System Ø100 - Ø150

    Available components for the concentric flue system - natural draught Ontop - Metaloterm US system Ø100 - Ø150 Fig. Ontop Art. / Description Order No. Adapter for Bellfires appliances with Ø100-Ø150 mm USA 10 concentric connection. US 25 10 Twin-wall balanced flue pipe, L = 250 mm. US 50 10 Twin-wall balanced flue pipe.
  • Page 48 Available components for the concentric flue system - natural draught Fig. Ontop Art. / Description Order No. USB 15 10 Twin-wall balanced flue elbow 15°. USDVC2 10 Vertical (roof) termination kit, L= 375 mm. USSR 10 Storm collar Ø150 mm. Adjustable roof flashing.
  • Page 49 Available components for the concentric flue system - natural draught Fig. Ontop Art. / Description Order No. USAB 10 Cover band, screw-fastening. USMB 10 Wall strap, adjustable. USEB 10 Fitting bracket. Set of ceiling finishing plates / Fire stops /Centering USCP 10 plates.
  • Page 50 Available components for the concentric flue system - natural draught Fig. Ontop Art. / Description Order No. USKBS 10 Locking band, screw-fastening. USI 10 Concentric pipe with inspection panel,L= 250 mm. USEM 10 Concentric pipe with gauging orifice,L= 150 mm. USBI 10 90°...
  • Page 51: Ontop - Metaloterm Us System Ø130 - Ø200

    Available components for the concentric flue system - natural draught Ontop - Metaloterm US system Ø130 - Ø200 Fig. Ontop Art. / Description Order No. Adapter for Bellfires appliances with Ø100-Ø150 mm USA 13 concentric connection. US 25 13 Twin-wall balanced flue pipe, L = 250 mm. US 50 13 Twin-wall balanced flue pipe.
  • Page 52 Available components for the concentric flue system - natural draught Fig. Ontop Art. / Description Order No. USB 15 13 Twin-wall balanced flue elbow 15°. 116 USDVC2 13 Vertical (roof) termination kit, L= 375 mm. USSR 13 Storm collar Ø150 mm. Adjustable roof flashing.
  • Page 53 Available components for the concentric flue system - natural draught Fig. Ontop Art. / Description Order No. USAB 13 Cover band, screw-fastening. USMB 13 Wall strap, adjustable. USEB 13 Fitting bracket. Set of ceiling finishing plates / Fire stops /Centering USCP 13 plates.
  • Page 54 Available components for the concentric flue system - natural draught Fig. Ontop Art. / Description Order No. USKBS 13 Locking band, screw-fastening. USI 13 Concentric pipe with inspection panel,L= 250 mm. USEM 13 Concentric pipe with gauging orifice,L= 150 mm. USBI 13 90°...
  • Page 55 Available components for the concentric flue system - natural draught Fig. Ontop Art. / Description Order No. USAH 13 Spacer bracket. Concentric reduction of Ø130-Ø200 mm → Ø100-Ø150 USVG 13 10 Gas Fire Front 90-60...
  • Page 56: Jeremias/Stb - H-Twin System Ø100 - Ø150

    Available components for the concentric flue system - natural draught Jeremias/STB - H-Twin system Ø100 - Ø150 Jeremias Fig. Art. / Order Description ATWINL Twin-wall balanced flue pipe. L= 1000 mm. 13100-150 ATWINL Twin-wall balanced flue pipe. L= 500 mm. 14100-150 ATWINL Twin-wall balanced flue pipe.
  • Page 57 Available components for the concentric flue system - natural draught Jeremias Fig. Art. / Order Description ATWIN 17 Twin-wall balanced flue elbow 30°. 100-150 ATWIN 18 Twin-wall balanced flue elbow 45°. 100-150 ATWIN Twin-wall balanced flue elbow 90°. 60100-150 ATWIN Twin-wall balanced flue elbow 90°...
  • Page 58 Available components for the concentric flue system - natural draught Jeremias Fig. Art. / Order Description ATWIN Roof termination - short with pipe,L = 300 mm, Vertical. 92100-150 ATWIN Roof termination, with pipe,L = 495 mm, Vertical, with 92pe100-15 roof flashing for existing chimney or flat roof. ATWIN Roof flashing for roof pitch 30°,with lead flashing and 45DD...
  • Page 59 Available components for the concentric flue system - natural draught Jeremias Fig. Art. / Order Description A681100-15 Horizontal (wall) termination kit, L= 495 mm (horizontal- ly adjustable), including one set of wall spacer plates. H-TWIN Concentric T-piece with gauging orifice. Inspection 752100-150 panel with cover cap and condensation-opening.
  • Page 60: Jeremias/Stb - H-Twin System Ø130 - Ø200

    Available components for the concentric flue system - natural draught Jeremias/STB - H-Twin system Ø130 - Ø200 Jeremias Fig. Art. / Order Description ATWINL Twin-wall balanced flue pipe. L= 1000 mm. 13130-200 ATWINL Twin-wall balanced flue pipe. L= 500 mm. 14130-200 ATWINL Twin-wall balanced flue pipe.
  • Page 61 Available components for the concentric flue system - natural draught Jeremias Fig. Art. / Order Description ATWIN 17 Twin-wall balanced flue elbow 30°. 130-200 ATWIN 18 Twin-wall balanced flue elbow 45°. 130-200 ATWIN Twin-wall balanced flue elbow 90°. 60130-200 ATWIN Twin-wall balanced flue elbow 90°...
  • Page 62 Available components for the concentric flue system - natural draught Jeremias Fig. Art. / Order Description H-TWIN Concentric T-piece with gauging orifice. Inspection 752130-200 panel with cover cap and condensation-opening. ATWIN 465 Adapter: H-TWIN Ø130-200 → Flex Stainless steel ; 130-200 Ø130 mm Incl.
  • Page 63: Jeremias - Twin-Gas System Ø100 - Ø150

    Available components for the concentric flue system - natural draught 6.10 Jeremias - TWIN-GAS system Ø100 - Ø150 Jeremias Fig. Art. / Order Description Bellfires Appliance connection / AdapterBellfires TWG163410 Ø100/150 mm → Jeremias TWIN-GAS Ø100/150 mmL 0-150 = 160 mmIncluding locking band (2x). TWG13100- Twin-wall balanced flue pipe, L = 1000 mmIncluding locking band.
  • Page 64 Available components for the concentric flue system - natural draught Jeremias Fig. Art. / Order Description TWG50100- Telescopic twin-wall balanced flue pipe,L= min. 330 / max. 420 mmIncluding locking band. TWG16100- Twin-wall balanced flue elbow 15°. Including locking band. TWG17100- Twin-wall balanced flue elbow 30°.
  • Page 65 Available components for the concentric flue system - natural draught Jeremias Fig. Art. / Order Description TWG272100 Roof termination (vertical) L= 615 mm.Including locking -150 band. Roof flashing with a roof pitch of 5° - 15°with flex. alu- TW53150 flashing and storm collar. Roof flashing with a roof pitch of 16°...
  • Page 66 Available components for the concentric flue system - natural draught Jeremias Fig. Art. / Order Description TW45150 Locking band, screw-fastening(spare part). ALBI26150 Silicone sealing ring for outer pipe(spare part). Wall strap. Distance to the wall: WA= 50 mm. WA704150 Extension pieces for the wall strap ZUWA704L= 130 WA891130 Extension pieces for the wall strap ZUWA704L= 200 WA891200...
  • Page 67 Available components for the concentric flue system - natural draught Jeremias Fig. Art. / Order Description Set of ceiling finishing plates / Fire stops with ventila- DA99VHL15 tion openings for a pitched roof : 0° - 30°. Set of ceiling finishing plates / Fire stopswith ventilation DA98VHL15 openings for a pitched roof : 31°...
  • Page 68 Available components for the concentric flue system - natural draught Jeremias Fig. Art. / Order Description TWG07100- Base plate / floor support. Wall support with transverse supportType I: 350 mm DW391 - Distance to wall: WA= max. 50 mm. Wall support with transverse supportType II: 500 mm DW392 - Distance to wall: WA= 50 - 150 mm.
  • Page 69: Jeremias - Twin-Gas System Ø130 - Ø200

    Available components for the concentric flue system - natural draught 6.11 Jeremias - TWIN-GAS system Ø130 - Ø200 Jeremias Fig. Art. / Order Description Bellfires Appliance connection / AdapterBellfires TWG163413 Ø130/200 mm → Jeremias TWIN-GAS Ø130/200 mmL 0-200 = 160 mmIncluding locking band (2x). TWG13130- Twin-wall balanced flue pipe, L = 1000 mmIncluding locking band.
  • Page 70 Available components for the concentric flue system - natural draught Jeremias Fig. Art. / Order Description TWG50130- Telescopic twin-wall balanced flue pipe,L= min. 330 / max. 420 mmIncluding locking band. TWG16130- Twin-wall balanced flue elbow 15°. Including locking band. TWG17130- Twin-wall balanced flue elbow 30°.
  • Page 71 Available components for the concentric flue system - natural draught Jeremias Fig. Art. / Order Description TWG272130 Roof termination (vertical) L= 615 mm.Including locking -200 band. Roof flashing with a roof pitch of 5° - 15°with flex. alu- TW53200 flashing and storm collar. Roof flashing with a roof pitch of 16°...
  • Page 72 Available components for the concentric flue system - natural draught Jeremias Fig. Art. / Order Description TW45200 Locking band, screw-fastening(spare part). ALBI26200 Silicone sealing ring for outer pipe(spare part). Wall strap. Distance to the wall: WA= 50 mm. WA704200 Extension pieces for the wall strap ZUWA704L= 130 WA891130 Extension pieces for the wall strap ZUWA704L= 200 WA891200...
  • Page 73 Available components for the concentric flue system - natural draught Jeremias Fig. Art. / Order Description Set of ceiling finishing plates / Fire stops with ventila- DA99VHL20 tion openings for a pitched roof : 0° - 30°. Set of ceiling finishing plates / Fire stopswith ventilation DA98VHL20 openings for a pitched roof : 31°...
  • Page 74 Available components for the concentric flue system - natural draught Jeremias Fig. Art. / Order Description TWG07130- Base plate / floor support. Wall support with transverse supportType I: 350 mm DW391 - Distance to wall: WA= max. 50 mm. Wall support with transverse supportType II: 500 mm DW392 - Distance to wall: WA= 50 - 150 mm.
  • Page 75: Modinox - Pla System Ø100 - Ø153

    Available components for the concentric flue system - natural draught 6.12 Modinox - PLA system Ø100 - Ø153 Color (*) Application Fig. Modinox Art./ Order No. Description stainles antr. rigid flex steel Bellfires appli- ance connec- tion: Adapter Bellfires Ø100/150 mm 2PLAMAFM100BEL ●...
  • Page 76 Available components for the concentric flue system - natural draught Color (*) Application Fig. Modinox Art./ Order No. Description stainles antr. rigid flex steel Twin-wall bal- anced flue 2PLAELDR1001000 ● ● pipe, L= 1000 mm., INOX Twin-wall bal- anced flue 2PLAELDR1001000NO pipe, L= 1000 ●...
  • Page 77 Available components for the concentric flue system - natural draught Color (*) Application Fig. Modinox Art./ Order No. Description stainles antr. rigid flex steel Twin-wall bal- anced flue el- 2PLACO15100 ● ● bow 15°, IN- Twin-wall bal- anced flue el- 2PLACO15100NO ●...
  • Page 78 Available components for the concentric flue system - natural draught Color (*) Application Fig. Modinox Art./ Order No. Description stainles antr. rigid flex steel Roof flashing, standard model, lead: 0,6mm thick, 2DIVS5PS160 ● ● for a roof pitch of 5°- 30°, with INOX cone Roof flashing,...
  • Page 79 Available components for the concentric flue system - natural draught Color (*) Application Fig. Modinox Art./ Order No. Description stainles antr. rigid flex steel Horizontal (wall) termina- tion kit, with 2PLATHOR100 rosettes, L= ● ● min. 580 mm / max. 780 mm. INOX Horizontal (wall) termina-...
  • Page 80 Available components for the concentric flue system - natural draught Color (*) Application Fig. Modinox Art./ Order No. Description stainles antr. rigid flex steel Rosette, IN- 2PLAROSA100BT ● ● Rosette, IN- 2PLAROSA100BTNO ● ● OX - BLACK Rosette, IN- 2PLAROSA100BTBL ●...
  • Page 81 Available components for the concentric flue system - natural draught Color (*) Application Fig. Modinox Art./ Order No. Description stainles antr. rigid flex steel Clearance 36 2PLAEPDS100 roof/floor pas- ● ● sage Adapter Modi- nox PLA → Flexible pipe, with chimney 2PLAADA71002020 ●...
  • Page 82 Available components for the concentric flue system - natural draught Color (*) Application Fig. Modinox Art./ Order No. Description stainles antr. rigid flex steel Adapter Modi- nox PLA → Flexible pipe, with chimney 2PLAADA71003030 ● ● ● bottom finish- ing plate 300x300mm, INOX Adapter Modi-...
  • Page 83 Available components for the concentric flue system - natural draught Color (*) Application Fig. Modinox Art./ Order No. Description stainles antr. rigid flex steel Adapter Flexi- ble pipe → Modinox PLA, with chimney 2PLAADA61002020 ● ● ● top finishing plate 200x200mm, INOX Adapter Flexi-...
  • Page 84 Available components for the concentric flue system - natural draught Color (*) Application Fig. Modinox Art./ Order No. Description stainles antr. rigid flex steel Insulation kit 2PTGKIRA100 + la ISORA for ● ● pente pitched roof passage Insulation kit ISORA for pitched roof passage, roof 2PTGKIRAV100 + la...
  • Page 85: Modinox - Pla System Ø130 - Ø200

    Available components for the concentric flue system - natural draught 6.13 Modinox - PLA system Ø130 - Ø200 Color (*) Application Fig. Modinox Art./ Order No. Description stainless antr. rigid flex steel Bellfires appli- ance connec- tion: Adapter Bellfires Ø130/200 mm 2PLAMAFM130BEL ●...
  • Page 86 Available components for the concentric flue system - natural draught Color (*) Application Fig. Modinox Art./ Order No. Description stainless antr. rigid flex steel Adapter Modi- nox PLA Ø130/200 mm → Modinox 2PLAMAFM130100 ● ● Ø100/153 mm. L= 225 mm. INOX Adapter Modi- nox PLA Ø130/200 mm...
  • Page 87 Available components for the concentric flue system - natural draught Color (*) Application Fig. Modinox Art./ Order No. Description stainless antr. rigid flex steel Telescopic twin-wall bal- anced flue 2PLAELRE130500 pipe, L= min. ● ● 300 / max. 500 mm., IN- Telescopic twin-wall bal- anced flue...
  • Page 88 Available components for the concentric flue system - natural draught Color (*) Application Fig. Modinox Art./ Order No. Description stainless antr. rigid flex steel Vertical (roof) termination 2PLACHAR130 ● ● cap, L= 360 mm, INOX Vertical (roof) termination 2PLACHAR130NO cap, L= 360 ●...
  • Page 89 Available components for the concentric flue system - natural draught Color (*) Application Fig. Modinox Art./ Order No. Description stainless antr. rigid flex steel Roof flashing, standard model, lead: 0,6mm thick, 2DIVS5PS200 ● ● for a roof pitch of 5°- 30°, with IN- OX cone Roof flashing,...
  • Page 90 Available components for the concentric flue system - natural draught Color (*) Application Fig. Modinox Art./ Order No. Description stainless antr. rigid flex steel Horizontal (wall) termina- tion kit, with 2PLATHOR130 rosettes, L= ● ● min. 580 mm / max. 780 mm. INOX Horizontal (wall) termina-...
  • Page 91 Available components for the concentric flue system - natural draught Color (*) Application Fig. Modinox Art./ Order No. Description stainless antr. rigid flex steel Rosette, IN- 2PLAROSA130BT ● ● Rosette, IN- 2PLAROSA130BTNO ● ● OX - BLACK Rosette, IN- 2PLAROSA130BTBL ●...
  • Page 92 Available components for the concentric flue system - natural draught Color (*) Application Fig. Modinox Art./ Order No. Description stainless antr. rigid flex steel Clearance 136 2PLAEPDS130 roof/floor pas- ● ● sage Adapter Modi- nox PLA → Flexible pipe, with chimney 2PLAADA71302020 ●...
  • Page 93 Available components for the concentric flue system - natural draught Color (*) Application Fig. Modinox Art./ Order No. Description stainless antr. rigid flex steel Adapter Modi- nox PLA → Flexible pipe, with chimney 2PLAADA71303030 ● ● ● bottom finish- ing plate 300x300mm, INOX Adapter Modi-...
  • Page 94 Available components for the concentric flue system - natural draught Color (*) Application Fig. Modinox Art./ Order No. Description stainless antr. rigid flex steel Adapter Flexi- ble pipe → Modinox PLA, with chimney 2PLAADA61302020 ● ● ● top finishing plate 200x200mm, INOX Adapter Flexi-...
  • Page 95 Available components for the concentric flue system - natural draught Color (*) Application Fig. Modinox Art./ Order No. Description stainless antr. rigid flex steel Insulation kit 2PTGKIRA130 + la ISORA for ● ● pente pitched roof passage Insulation kit ISORA for pitched roof passage, roof 2PTGKIRAV130 + la...
  • Page 96 Your Barbas dealer 002 - 21.07.2022 - 352518 - 252-002...

Table of Contents