Important Safety Information
• Always turn off the main power when the plastic cover of the thermostat is removed.
• Read carefully the information included in this manual before install for operation the thermostat.
• The used power is the main power of 230Volts AC/50Hz and the installation should be done by authorized person.
• Avoid places of high humidity for the installation.
• Do not try to use the thermostat for other applications except those that is made to be used i.e. central heating
This thermostat is not an instrument. It must not be used in life critical applications.
Features
• The sensitivity of the thermostat depends on the ability to display in the temperature spectrum of +5°C to +35°C.
• Adjustable from +5°C to +35°C.
• Adjustable high and low temperature limits (for hotels, offices, schools etc.).
• Displays "Lo" and "Hi" indication when temperature reaches the lower or the upper limit.
• Temperature can be adjusted in steps of 0.1 °C.
• The accuracy is within ±1°C.
• Memory is available in case power failure.
• Contains light indicators for "SET", "ON/OFF", and "ORDER" conditions.
Incorporates variable differential and sensed temperature trimming function (for installers only).
Installation
Install the thermostat always in an inside wall in a height of 1.2m to 1.5m from the floor and away of corners, room places affected of heat
generating appliances, air vents or places directly exposed to sunlight. All above reasons may affect the correct thermostat operation.
1. Turn OFF the power of the heating system.
2. Remove the plastic cover of the thermostat simply by pressing the two anchors in both lateral sides.
3. Place thermostat against the wall at desired location. Make sure the wires will feed through opening on its base.
4. Mark the position of mounting holes and drill them.
5. Secure and align the thermostat in the wall by fixing the two screws. Do not over tighten the screws.
6. Connect the appropriate wires to cable terminal strip as shown in the wiring diagram.
7. Replace the plastic cover.
8.
Switch ON the power of the heating system.
Operation
When the installation is accomplished the thermostat operates as a digital thermometer. Press the "ON/OFF" button. A green indicator
lights on. Repressing the same as above "ON/OFF" button the thermostat goes OFF. Adjustment of the desired temperature when
thermostat is ON is made by pressing either the button signed with
shows the desired temperature. Once the desired temperature is set up correctly the thermostat affects the heating system in order to
maintain the temperature as close as possible into the setting. When the room temperature is lower than the desired the red indicator lights
on and the electrical contact is closed. When the room temperature exceeds the desired point the red indicator is switched off and the
electrical contact opens.
The thermostat has a factory preprogrammed differential of -0.6 °C which is well suited for home heating applications. The temperature
differential can be adjusted from –0.1°C to –1.0°C. Differential adjustments must be done exclusively from authorized personnel. Incorrect
adjustment has serious danger and may affect the correct operation as well as the stability of the system. For the same reason take care when
performing trimming to improve sensed temperature accuracy. This adjustment is also allowed to experienced installers only. Refer to
Charmeg for detailed trimming procedures.
This product has been manufactured from materials which can be recycled and reused according to the European Directive 2002/96/EC.
Please be informed regarding the local collection system for electrical and electronic equipment and do not dispose the old products with
your normal household waste.
The correct disposal of the products will help to prevent the negative consequences of the environment and human health.
MP-R
Digital Thermostat and Thermometer
or
symbols. A yellow colored indicator lights on and the display
Technical Characteristics
Physical dimensions
110x62x31mm approx.
Mains power
~230V AC/50Hz ±10%
Electrical contact rating
5A/250VAC 5A/30VDC
Adjust limits
+5°C to +35°C
Differential
-0.6°C(-0.1°C to -1.0°C for authorized personnel)
Sensed temp. trimming
-3.0°C to +3.0°C (for authorized personnel)
Operating temperature
-10°C to +50°C
Temperature
Increase button
Temperature
Decrease button
MP-R
ON/OFF button
Outside front view
Mounting Hole
Example for 230V burners
4 3 2 1
To burner
Short circuit
27 Kotronos str. Aegaleo-Athens- Greece
Tel. +030 210 5693111, Fax.+030 210 5693093, www.charmeg.gr
SET mode
Display
indicator
ON indicator
ORDER
indicator
4 3 2 1
Wire terminal strip
Wire pass through
Inside front view
4 3 2 1
230V AC
L N
Electrical Contact
230V AC
230V AC
L N
L N
Wiring diagram
MPR2006
Doc. No: User's Manual_MP_R_4.doc
Mounting Hole
opening