Oasis N-CNG P30 Installation And Operating Manual

Cng nozzle

Advertisement

Quick Links

N-CNG P30 / P36
CSA/ANSI NGV 1-2017 + ISO 14469:2017
CNG NOZZLE
INSTALLATION AND OPERATING MANUAL
OASIS ENGINEERING LIMITED · 129 Birch Avenue, Tauranga, New Zealand
Tel. +64 07 928 38 08 · Email: info@oasisngv.com
22 . 2022

Advertisement

Table of Contents
loading

Summary of Contents for Oasis N-CNG P30

  • Page 1 N-CNG P30 / P36 CSA/ANSI NGV 1-2017 + ISO 14469:2017 CNG NOZZLE INSTALLATION AND OPERATING MANUAL OASIS ENGINEERING LIMITED · 129 Birch Avenue, Tauranga, New Zealand 22 . 2022 Tel. +64 07 928 38 08 · Email: info@oasisngv.com...
  • Page 2 Please read this manual carefully before installation or operation of the nozzle. Be sure all instructions are understood. Correct installation, use and maintenance are essential. In case of doubt or question, please contact your service contractor or the manufacturer. DESCRIPTION The N-CNG nozzle is designed for CNG refuelling of vehicles equipped with receptacles to NGV1 or ISO 14469.
  • Page 3: Installation

    High pressure gas and gas equipment can cause serious harm to both infrastructure and personnel if safety precautions are not followed. Oasis recommends the use of personal protective equipment ( PPE ) when working with high pres- sured gases ( CNG ) in accordance to the relevant health and safety regulations:...
  • Page 4 Ensure the system is free of dirt and foreign matter, vented and isolated before any installation or servicing work is carried out. The N-CNG is delivered ready for use. This installation must only be done by an authorised service engineer who is trained to ensure com- pliance with all relevant national regulatory conditions.
  • Page 5: Troubleshooting

    After connecting to the hose assembly, an ope- rational test shall be performed. It is essential to examine that the nozzle, hose connector and swivel are tight under pressure and do not leak – e.g. by external application of foaming agents. ...
  • Page 6 OPERATING INSTRUCTIONS Please follow any additional or deviating operating instructions displayed at the dispenser. Turn off vehicle engine. Take nozzle from dispenser. Push nozzle firmly onto the vehicle Ensure that all coupling parts, seals and sealing surfaces of Align nozzle with vehicle filling point.
  • Page 7: Maintenance

    A technical expert of your choosing should validate all operating parameters for each application. Oasis has made every effort to explain all servicing procedures, warnings, and safety precautions as clearly and completely as possible. However, due to the range of operating environments, it is not possible to anticipate every issue that may arise.
  • Page 8: Warranty

    WARRANTY Oasis guarantees against defective materials and manufacturing for 12 months from date of supply. If the delivery date cannot be established, the production date applies. This can be traced back by the serial number on the CNG nozzle bodies.

This manual is also suitable for:

N-cng p36