Page 1
INSTRUCTION MANUAL TB135x Emission 04/11/11 G. Paulitti C. Laserra Rev. Subject of the revision Date Prepared Checked Approved 1513.doc 1513-MPTB13ME Rev. 0 Pag. 1 di 12...
TBL13x is a numerical repeater with a digit size of 135 mm. The repeater is driven from serial line. The repeater can be assembled with 5 red Digits. The repeaters can be connected directly to ADOS weighing instruments (A200E, A100E, T050E, T060E, A101E, A120E) or to other host system using the same protocol.
ADOS S.R.L. Buccinasco (MI) 1.4 Nameplate Each unit contains information necessary for a correct identification, model and serial number. These data together with the software version shall be given in case of inquiry. It is important to provide this information when requesting information or instructions regarding the instrument, along with the programme version, which are shown on the manual and is displayed when the instrument is switched on.
ADOS S.R.L. Buccinasco (MI) Baud rate selection To configure the speed of the serial line open the case unscrewing the eight external screws, turn down the top part of the case. The programming operation is performed by the four keys places on the CPU board.
ADOS S.R.L. Buccinasco (MI) D O N E If this word appears it means that the setting has been successful. The configuration parameter available is as follow: BAUD velocità di trasmissione (baud rate) (1200 – 2400 – 4800 – 9600)
ADOS S.R.L. Buccinasco (MI) SERIAL INTERFACE MANAGEMENT The serial line is available in both the RS232 and RS485 mode. Selection is made by means of a jumper on CPU. Operating parameter of the serial line are: 8 bit - No Parity - 1 Stop...
ADOS S.R.L. Buccinasco (MI) INSTALLATION Material receiving Remove the instrument from its packing and check if it has been damaged during transport. Claims for any damage must be submitted immediately and in writing to the supplier and to the carrier which delivered the goods.
ADOS S.R.L. Buccinasco (MI) Wiring All connection to the repeater are made using two Harting connectors. WARNING Any wiring must be done when the instrument is powered off Check carefully the value of the power supply and the power supply wiring ANY CONNECTION ERROR VOIDS WARRANTY The connection to the safety ground must always be done.
ADOS S.R.L. Buccinasco (MI) 3.3.2 Serial port connection Connections must be done with a shielded cable (RS232 lines) or with a twisted pair shielded cable (RS 485 lines). The cable must not be channelled with other cables (i.e. outputs connected to remote switches or power supply wires), but must follow its own route.
ADOS S.R.L. Buccinasco (MI) Zero input option In the TB135x-I version the repeater provides for the possibility, through a contact closure, to zeroing the reading. The function is lost with the shutdown of the equipment. There are not effects of loss of safety function in case of load limiting systems (zero being carried out only locally on the repeater).
For safety reason is a good practice to check periodically, by visual inspection, the connections to the protective earthling system. Corrective maintenance Any corrective maintenance to possible failures must be carried out at ADOS laboratories or at least by ADOS authorized personnel EVERY UNAUTHORIZED ACCESS TO THE INSTRUMENT VOIDS WARRANTY 1513-MPTB13ME Rev.