Download Print this page

Huawei S7700 Series Quick Maintenance Manual page 10

Smart & core routing switches

Advertisement

Check the Card Status
Log in to the switch
and run the display device command to view card
<HUAWEI> display device
S9712's Device status:
Slot
Sub Type
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
7
-
EH1D2X02XEC0 Present
10
-
EH1D2G48SEC0 Present
13
-
EH1D2SRUDC00 Present
14
-
EH1D2SRUDC00 Present
PWR1
-
-
PWR2
-
-
CMU1
-
EH1D200CMU00 Present
FAN1
-
-
FAN2
-
-
FAN3
-
-
FAN4
-
-
Check the following items:
Whether the Online value is Present.
Whether the Power value is PowerOn.
Whether the Register value is Registered.
Whether the Alarm value is Normal.
If the card status is abnormal, record the fault information and handle the fault according to the
Troubleshooting
Guide. If the fault cannot be rectified, contact your agent or Huawei enterprise
technical support hotline.
Online
Power
PowerOn
PowerOn
PowerOn
PowerOn
Present
PowerOn
Present
PowerOn
PowerOn
Present
PowerOn
Present
PowerOn
Present
PowerOn
Present
PowerOn
7
status.
Register
Alarm
Registered
Normal
Registered
Normal
Registered
Normal
Registered
Normal
Registered
Normal
Registered
Normal
Registered
Normal
Registered
Normal
Registered
Normal
Registered
Normal
Registered
Normal
Primary
NA
NA
Master
Slave
NA
NA
Master
NA
NA
NA
NA

Advertisement

loading

This manual is also suitable for:

S9700 series