DIGITAL INTEGRATED POWER SUPPLY OZONE
AQUAZONE 200G TO 400G OZONE GENERATOR
USER MANUAL
200G
300G
400G
600G
Note
Equipment should be installed in a clean environment with good ventilation.
To prevent backflow water, gas-liquid mixing connections should be installed strictly according to this guide.
At least allow 5 seconds to turn on and off the ozone generator.
Please keep the equipment clean and dry.
It is prohibited to operate the equipment before connecting with cooling water.
PLEASE READ THROUGH THIS USER MANUAL BEFORE INSTALLING THE EQUIPMENT

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the AQUAZONE 200G and is the answer not in the manual?

Questions and answers

Summary of Contents for BioZone AQUAZONE 200G

  • Page 1 DIGITAL INTEGRATED POWER SUPPLY OZONE AQUAZONE 200G TO 400G OZONE GENERATOR USER MANUAL □ □ □ □ 200G 300G 400G 600G Note Equipment should be installed in a clean environment with good ventilation. To prevent backflow water, gas-liquid mixing connections should be installed strictly according to this guide.
  • Page 2: Table Of Contents

    INSTALLATION PLACE REQUIREMENT PIPING INSTALLATION ELECTRICAL CONNECTION ON / OFF PROCEDURE NOTES MAINTENANCE AND TROUBLESHOOTING WARRANTY TERMS BIOZONE AFTER SALE SERVICE COMMITMENT MAINTENANCE ITEMS MAINTENANCE CYCLE TABLE TROUBLE ANALYSIS AND INSPECTION (TABLE 6-2) PSU ERROR CODE AND SOLUTION CONTACT US...
  • Page 3: Safety Notes

    ● The scope of the user manual ○ The user manual is for our Aquazone 200g - 400g series products. ● Purpose of the user manual ○ Served as the instruction for operation personnel ● Knowledge required for understanding the user manual ○...
  • Page 4: Safety Note

    ● During operation, the equipment generates high voltage. Hence, it is prohibited to open the equipment control panel and power control cabinet. ● There is a safety breaker in the front enclosure, and when the front enclosure of the equipment is open.
  • Page 5: Product Description

    ● Do not use heating appliances near the equipment, which may lead to melt of the plastic components. ● Keep the equipment external clean. ● During a long non-operation period, the power source should be disconnected and the equipment be covered with plastic sheeting.
  • Page 6: Specifications

    SPECIFICATIONS Model 200G 300G 400G 600G Parameter Capacity (g/hr) Voltage 3*380V Frequency 50/60Hz 3*5A each set 3*3.5A each set Rating current 3*3.5A 3*5A sets modular Two sets modular design design Power Working pressure ≤0.2bar Cooling water flow( 6LPM 10LPM 12LPM 20LPM 25℃)...
  • Page 7: Control Panel And Interface

    CONTROL PANEL AND INTERFACE 4.1 CONTROL PANEL DESCRIPTION ● Ozone regulating knob ○ Amount of ozone can be adjusted by adjusting the working current and the adjustable range is from 0% to 100% ● Power indicator ○ Light up when equipment work normally ●...
  • Page 9: 300G Interface

    ● Equipment side interface description ○ Flow meter ○ Ozone generator input gas flow display ● Gas source input ○ Either oxygen input or air input ● Cooling water inlet ○ It is advised to use tap water for cooling water. If use other water or circulating water, Polypropylene (PP) cotton water filter should be installed before cooling water inlet, otherwise impurities in the water or metal oxides will lead to insufficient heat dissipation.
  • Page 10: 200G, 400G And 600G Interface (Two Sets,Modular Design)

    200G, 400G AND 600G INTERFACE (TWO SETS,MODULAR DESIGN)
  • Page 11: 20Ma Analog Signal Receiving Port

    4~20MA ANALOG SIGNAL RECEIVING PORT...
  • Page 12: Installation And Maintenance

    INSTALLATION AND MAINTENANCE INSTALLATION PLACE REQUIREMENT Equipment should be installed indoors, with clean, adequate light and a good air circulation environment. It is prohibited to be installed in the environment of exposure to sunlight, rain, water vapour, moisture, corrosive gas, explosive gas and dust. Environment temperature should be lower than 40℃,humidity lower than 70℃...
  • Page 13: Notes

    Fail to provide proof of purchase or serial numbers are not attached to the units. ● If on-site service is required, customers will be required to pay for the cost of travelling, and Biozone or distributor can decide to come or not according to the distance.
  • Page 14: Maintenance Cycle Table

    ● High voltage parts water removal: during the humid season, there is moisture on the connecting cable of the transformer (the high voltage unit), transformer, and the connecting cables of the ozone module. Dry it with cloth and hair dryer. Otherwise, it may lead to damage to the equipment. ●...
  • Page 15: Trouble Analysis And Inspection (Table 6-2)

    TROUBLE ANALYSIS AND INSPECTION (TABLE 6-2) Number Problem analysis inspection Check the power source. Power plug/ power cabinet no power No power Replace the fuse and check if the voltage is Internal fuse broken normal. Gas source is not connected. Reconnect gas source Turn on flow meter No flow from...
  • Page 16: Psu Error Code And Solution

    PSU ERROR CODE AND SOLUTION Error Description Possible cause Solution code E001 Over Input voltage too low Check the mains voltage, and make sure current correct and firm connection E002 Working current changes too fast Slower regulation control E003 Rapid changes on the load or problem with Check ozone cell and HV transformer the loads E004...
  • Page 17: Contact Us