5.2.3. Programming the Stages _______________________________________________________7 5.2.4. Setting the System Clock _______________________________________________________7 5.2.5. Saving and Restoring Levels ____________________________________________________7 5.2.6. Calibrating the Temperature Sensors______________________________________________8 5.2.7. Artificial Light _______________________________________________________________8 5.2.8. Feed Control_________________________________________________________________8 5.2.9. Viewing All Sensors___________________________________________________________8 System 2000 AUTO TEMP Table of Contents...
System 2000 Auto Temp Specifications Model: ACT-12 -- Staged on/off controller with 7 temperature inputs and 13 relay outputs Electrical Ratings Voltage Input -- 120 VAC (240VAC available) 50/60 Hz. Power Consumption -- 20 VA Max. Contact Ratings: 1/10 HP Inductive @ 120VAC...
Installation by qualified electrician required. Description of Controller The Hired-Hand System 2000 Auto Temp Controller is a 12 relay, on/off, temperature/timer actuated, staged controller. The controller also features 7 temperature inputs. The System 2000 offers several unique and useful features. One such feature is that the Auto Temp can be programmed to control up to 6 separate rooms.
Programming the System Programming the System 2000 Auto Temp Controller is like many other things--at first glance it looks complicated, but if taken one step at a time it is really easy. In terms of programming the controller can be broken down into two components.
The system is locked by pressing the Change Setting up and down arrows simultaneously and holding them until the word locked appears in the facepad. The system is System 2000 AUTO TEMP...
10 (7 days + 3 days). 6.2.1.3. Set Mortality To use the flock calculator, you need to enter the number of deceased birds each day. Use the Change Setting up and/or down arrow keys to set the number you System 2000 AUTO TEMP...
If you wish to use an average of sensors 1,2, and 3 for this particular room, simply push the buttons for stages 1, 2, and 3 until those 3 are lighted. You will be prompted for sensors for Display for each of the Rooms selected in "Number of Rooms". System 2000 AUTO TEMP...
6.2.3. Programming the Stages The System 2000 Auto Temp controller is an integrated 12 stage controller with a built in timer. Each of the 12 stages can be programmed to be either a heat or a cool stage.
The temperatures shown will update every 4 seconds while they are being displayed. Recommended Wire Gauge for LOW VOLTAGE hookup. Component HHI Wiring Part No. Recommended Wire Sensor 1502-2427 18/2 Shielded Cable Hall Effect Devices 1502-2427 18/2 Shielded Cable PVR-H 1503-1508 18/3 Cable SJT System 2000 AUTO TEMP...