RETENTION PENSTOCK - FL SERIES ASSEMBLY DIRECTIVES Machinery Directive: DIR 2006/42/EC (MACHINERY). Pressure Equipment Directive: DIR 97/23/EC (PED) ART.3, P.3. Potentially Explosive Atmospheres Directive (optional): DIR 94/9/EC (ATEX) CAT.3 ZONE 2 and 22 GD. The FL penstock complies with the Directive on Equipment and Protective Systems for Potentially Explosive Atmospheres.
Page 3
RETENTION PENSTOCK - FL SERIES ASPECTS TO BE CONSIDERED DURING ASSEMBLY When mounting the penstock, it is vitally important that the turning point of the flap (body lugs) are, whatever the type of atta- chment or type of penstock, in the upper part of the penstock, in order to ensure that the force of gravity closes the flap.
Page 4
RETENTION PENSTOCK - FL SERIES • Ensure that the sealtight joint between the flange and the penstock is correctly positioned. • After correctly positioning both the sealtight joint and the penstock, fasten the joining bolts. These bolts and nuts must be suitable for the operating conditions.
Page 5
RETENTION PENSTOCK - FL SERIES Body Wall SIKAFLEX-11FC Fig. 6 These are the most common attachment options, although, as mentioned on other occasions throughout this manual, the design of these FL penstocks is defined in accordance with the customer’s requirements in each specific project. In consequence, if you require a different attachment option, contact CMO’s technical sales department for a bespoke project in line with your needs.
Page 6
RETENTION PENSTOCK - FL SERIES ASSEMBLY POSITIONS This type of penstocks can be mounted on a vertical flange (fig. 7) located at the end of a horizontal pipe, or mounted on a vertical wall (fig. 8) in which there is a square, round or rectangular orifice. Whatever the type of installation, the position of the penstock is vertical.
Page 7
RETENTION PENSTOCK - FL SERIES ACTUATOR These FL penstocks do not have an actuator system, but rather are automatic. It is the fluid which opens or closes the penstock. When the fluid comes from inside the pipe to the outside, it pushes on the flap which swivels on the turning point and opens the penstock.
RETENTION PENSTOCK - FL SERIES MAINTENANCE CMO will not be liable if the penstocks suffer any damage due to improper handling or without proper authorisation. The penstocks must not be modified except under express authorisation from CMO. The following instructions should be followed in order to avoid personal injury or material damage when carrying out maintenance tasks: •...
Page 9
RETENTION PENSTOCK - FL SERIES REPLACING THE SEALING JOINT Make sure there is absolutely no pressure or fluid in the facility. Place the flap (2) in completely open position. Secure the flap (2) in this position using more than one system.
RETENTION PENSTOCK - FL SERIES STORAGE To ensure the penstock is in optimum conditions of use after long periods of storage, we recommend storing it in a well-ventilated place at temperatures below 30ºC. It is not advisable, but, if stored outside, the penstock must be covered to protect it from heat and direct sunlight, with good ventilation to prevent humidity.
Page 11
RETENTION PENSTOCK - FL SERIES www.cmovalves.com NORTH AMERICA EUROPE ASIA MIDDLE EAST AFRICA AUSTRALIA & OCEANIA SOUTH AMERICA CMO HEADQUARTERS CMO MADRID MAIN OFFICES & FACTORY C/ Rumania, 5 - D5 (P.E. Inbisa) Amategi Aldea, 142 28802 Alcalá de Henares...
Need help?
Do you have a question about the FL Series and is the answer not in the manual?