IPC Eagle Ultra Pure Systems Hydro Cart Compact Operation Manual

Reverse osmosis/deionizing water production machines designed for water fed pole window cleaning

Advertisement

Quick Links

Ultra Pure Systems
Hydro Cart Compact
Reverse Osmosis / Deionizing water production machines designed for
water fed pole window cleaning.
OPERATIONS MANUAL
12450 Oliver Avenue South #300 • Burnsville, MN 55123
651.686.5399 • Fax 651.686.5695 • 800.486.2775
www.ipceagle.com
1.
p. 1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Ultra Pure Systems Hydro Cart Compact and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for IPC Eagle Ultra Pure Systems Hydro Cart Compact

  • Page 1 Ultra Pure Systems Hydro Cart Compact Reverse Osmosis / Deionizing water production machines designed for water fed pole window cleaning. OPERATIONS MANUAL 12450 Oliver Avenue South #300 • Burnsville, MN 55123 651.686.5399 • Fax 651.686.5695 • 800.486.2775 www.ipceagle.com p. 1...
  • Page 2: System Overview

    System Overview The following information is provided to help you understand how the system operates. • Pure water production volume on any Reverse Osmosis system is temperature dependant. o Colder feed water, i.e. the late fall, winter and early spring will produce a lower volume (gpm) of pure water.
  • Page 3 Table of Contents Title Page Title Page System Overview New System Testing 3 & 4 System Analysis Machine Setup Exploded Parts View Spare Membrane installation Parts List Prefilter installation Notes DI Resin Cartridge installation RO Membrane Replacement Warranty Policy HydroCart Compact Warranty QR Code Operation Maintenance RO Membrane Protection...
  • Page 4 3. Wheel Assembly 1. Insert Axel into Frame Tube 2. Slide a spacer over Axel on both sides 3. Place a wheel on both sides of Axel 4. Using a hammer, tap push nut onto each end of Axel Installation Video (Scan to watch) 4.
  • Page 5: Filter Installation

    Filter Installation Carbon Sediment cartridge Installation: • The 5 micron carbon/sediment filter cartridge is the first filter the feed water goes through. Install it in the housing on the right side, next to the water supply hose inlet fitting. 1. Slide the small filter housing wrench up from under the bottom of the white housing and turn CCW to loosen.
  • Page 6: Ro Membrane Replacement

    RO Membrane Replacement 1. Disconnect the black hose from the top cap of the RO housing. 2. Remove the clamp holding the top cap on. 3. Remove the top cap by using a screwdriver to pry the top cap up. There are two notches on opposite side of each other to pry cap up.
  • Page 7 HydroCart Compact Operating Instructions SETUP 1. The machine may be operated standing upright or lying down. Choose the position that offers the most stability at the job site. 2. Choose a location close to the water supply tap if possible. Extension garden hoses may be used but must be 5/8 inch inside diameter or larger to minimize line pressure loss.
  • Page 8: Maintenance

    Maintenance DAILY IMPORTANT: After the last use of the day, drain the RO membrane by letting water flow out of the waste water hose after removing supply water. This will help flush the concentrated water from the membrane and increase the life of the membrane.
  • Page 9 RO Protect ™ RO Membrane Protection & Storage Solution Set green discharge hose onto the ground and let waste water flow out of the sysem. Ultra Pure series Hydro Cart Compact long term storage instructions Pour entire package of RO Protect™ into 1gallon System Preparation: of pure water or distilled 1.
  • Page 10: Troubleshooting Procedures

    Troubleshooting Procedures Condition Solution Low supply water flow or pressure 1. Eliminate all extension hoses and connect directly to spigot with a single hose. 2. Check for blockage or kinks in hose. 3. Connect to different water source. 4. Clean or replace sediment filter. High wastewater flow with low 1.
  • Page 11 Troubleshooting Procedures System performance evaluation: In order to properly evaluate and troubleshoot the system, you will need to perform a complete set of tests on the unit. These tests will help identify the cause of the problem. To run these tests, you will need the following items: •...
  • Page 12: System Testing

    System Testing 1. Set up unit to run as per operation/owners manual. Remove DI cartridge filter before testing and reattach DI cartridge housing housing. 2. Before connecting the supply water hose to the machine, measure the water flow from the end of the hose(s). •...
  • Page 13: System Analysis

    If after performing all tests and working through the matrix you still have operational please fill out this form completely issues, before contacting IPC Eagle Technical Service Department. This information is required for proper evaluation of the system. p. 13...
  • Page 14 Exploded View p. 14...
  • Page 15 Spare Parts List Item # Part # Description BD555075 Frame BD555086 Handle BD555088 Axel BD555085 Spacer BD555059 Wheel BD545150 Axel Push Nut BD555076 Tube Cap BD411521 Hex Bolt, 5/16 - 18 x2.5" L. BD442000 Nut, Nylock 5/16-18 BD432001 Washer, Flat 5/16 USS BD505104 Pre-filter Housing BD407001...
  • Page 16 Notes p. 16...
  • Page 17 IPC Eagle will furnish and charge for replacement parts, including transportation, to the original owner through an IPC Eagle authorized service center. If the part is returned within 30 days and is found defective, the owner will be credited for the cost of the replacement part including shipping and handling.
  • Page 18 IPC EAGLE PRODUCT WARRANTY Thank you for choosing to partner with IPC Eagle. Your IPC Eagle Product has been thoroughly tested and inspected and is warranted to be free of defects in material and workmanship for a specific period, depending on the product purchased. This warranty does not cover normal wear items such as brushes, belts, filters, power cords.

Table of Contents