Table of Contents

Advertisement

Quick Links

RapidDome/RapidDome Gold
MNRDRG120902US
ADEMCO Video
Installation and Operation
Guide
RapidDome/RapidDome Gold
Document reference and revision – MNRDRG120902US
Page 1 of 51

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the RapidDome and is the answer not in the manual?

Questions and answers

Summary of Contents for ADEMCO VIDEO RapidDome

  • Page 1 RapidDome/RapidDome Gold MNRDRG120902US ADEMCO Video Installation and Operation Guide RapidDome/RapidDome Gold Document reference and revision – MNRDRG120902US Page 1 of 51...
  • Page 2: Table Of Contents

    RapidDome/RapidDome Gold MNRDRG120902US Table Of Contents Preface ..................... 4 About the RapidDome/RapidDome Gold range ........4 Key Installation Features................5 Safety instructions..................6 Safety instructions..................7 System Requirements................8 Basic System Example ................9 System Planning..................10 Example System Layout................. 11 Power Supply ..................
  • Page 3 Connection Table For Alarm Inputs and Outputs ........33 Alarm Output Control ................34 Alarms To The RapidDome/RapidDome Gold Head Functionality..35 Alarms To The RapidDome/RapidDome Gold Head Function Table ..35 Cable Termination Internal Units ............36 Power Up Precautions ................36 Plug And Play Fitting................
  • Page 4: Preface

    RapidDome/RapidDome Gold unit. About the RapidDome/RapidDome Gold range The RapidDome/RapidDome Gold range combines state of the art technology with easy “plug and play” installation and the minimum of engineer set up required. The range features a number of camera and lens options including: •...
  • Page 5: Key Installation Features

    • Alarm devices can be connected directly to the RapidDome/RapidDome Gold head, 4 for RapidDome and 8 for RapidDome Gold. • Relay outputs available at the RapidDome/RapidDome Gold head, 1 for RapidDome, and 2 for RapidDome Gold. • Storage of programmable settings in onboard battery backed RAM.
  • Page 6: Safety Instructions

    Never point the RapidDome/RapidDome Gold directly towards a bright light source (e.g. the sun) for an extended period of time. Never expose the RapidDome/RapidDome Gold to light intensive situations. Permanent and irreparable damage to the camera’s pick up device may result.
  • Page 7: Safety Instructions

    ADEMCO Video products are sold in accordance with our general terms and conditions of sale and delivery. ADEMCO Video reserves the right to change the design and specification of products and information regarding products without notice.
  • Page 8: System Requirements

    MNRDRG120902US System Requirements RapidDome/RapidDome Gold receive commands from the system controller, this can be an ADEMCO Video matrix, an ADEMCO Video Digital Recorder, or a third party controller. If a third party controller is to be used, the controller must support ADEMCO Video control code protocol, or the RapidDome/RapidDome Gold must support the third party controllers’...
  • Page 9: Basic System Example

    Figure1 Figure 1 shows a possible system configuration. A 2 monitor output ADEMCO Video matrix is used as the heart of the control system and also sends and receives all control code information to and from the attached RapidDome/RapidDome Gold units.
  • Page 10: System Planning

    Important considerations are: • The RS 485 addresses of the RapidDome/RapidDome Gold shown with the dome location. • The RS 485 data cable route. This should clearly show where the daisy chain begins and also where it ends.
  • Page 11: Example System Layout

    RapidDome/RapidDome Gold MNRDRG120902US Example System Layout Figure 2 Page 11 of 51...
  • Page 12: Power Supply

    RapidDome/RapidDome Gold MNRDRG120902US Power Supply Although the RapidDome/RapidDome Gold range is dual power capable (12vdc / 24vac) it is recommended that all new installations are equipped with the correct 24VAC supply. Application type Part Number Specification Indoor–1 per RapidDome PS1824 24VAC 40VA Indoor–Up to 8...
  • Page 13: Power Supply Location

    Power Supply Location The power supply should be located as close to the RapidDome/RapidDome Gold as possible for service and electrical isolation purposes. This approach is not practical in all cases and the power supply may in some cases have to be installed remote from the RapidDome/RapidDome Gold location.
  • Page 14: Coaxial Video Cabling Specifications And Distances

    Coaxial cable runs of up to 2,300 feet, (700 meters). A video amplifier is fitted as standard to all RapidDome/RapidDome Gold units to allow adjustment for correct video levels and quality over any length of cable run up to 2,300 feet (700 meters).
  • Page 15: Coaxial Video Cabling Notes

    RapidDome/RapidDome Gold MNRDRG120902US Coaxial Video Cabling Notes There are a number of precautions that must be considered before running the Coaxial cables to minimise the possibility of problems with the video signal. The quality and specification of the cable used will have a direct affect on the quality of the video signal at the control equipment end of the system.
  • Page 16: Cat 5 Twisted Pair Video Cabling Background

    RapidDome/RapidDome Gold MNRDRG120902US CAT 5 Twisted Pair Video Cabling Background Most RapidDome/RapidDome Gold mountings feature built in UTP transmission modules. This provides the option of cabling the video signal down a single twisted pair of a CAT5 multipair cable, instead of traditional Coaxial cable.
  • Page 17: Cat 5 Twisted Pair Video Cabling Specifications And Distances

    RapidDome/RapidDome Gold MNRDRG120902US CAT 5 Twisted Pair Video Cabling Specifications And Distances The table below shows distances and ADEMCO Video UTP options to suit most RapidDome/RapidDome Gold units. Distance Receiver model and description Coaxial video control code Up to 500...
  • Page 18: Cat 5 Twisted Pair Video Cabling Notes

    16 cameras via CAT5. Coaxial video control code is possible when a passive ADEMCO Video receiver module or hub is used at the control end of the system. If an active receiver is used...
  • Page 19: Rs 485 Twisted Pair Control Code Theory

    RapidDome/RapidDome Gold MNRDRG120902US RS 485 Twisted Pair Control code Theory RapidDome/RapidDome Gold units will only deliver the full feature set when using RS 485 twisted pair control code in conjunction with an ADEMCO Video control code matrix controller. When using RS 485 twisted pair control code the video signal is transmitted via a Coaxial or CAT5 twisted pair cable and the control code information is sent as data via another twisted pair cable.
  • Page 20: Rs 485 Twisted Pair Control Code Termination

    The RapidDome/RapidDome Gold domes represent other devices on the network and only the end of line RapidDome/RapidDome Gold should have the termination selected as “on”. All RapidDome/RapidDome Gold domes between the first and last device should have the termination selected as “off”.
  • Page 21: Rs 485 Twisted Pair Control Code Cabling

    RapidDome/RapidDome Gold MNRDRG120902US The diagram above illustrates correct RapidDome/RapidDome Gold termination on a medium sized system with 3 daisy chains. RS 485 Twisted Pair Control code Cabling There are a number of precautions that must be considered before running the data cables to minimise the possibility of data corruption that could lead to poor control code performance.
  • Page 22 RapidDome/RapidDome Gold MNRDRG120902US Faulty cabling or wiring can cause all RapidDome/RapidDome Gold units to fail or malfunction. Page 22 of 51...
  • Page 23: Rs 485 Twisted Pair Control Code Cables And Distances

    ADEMCO Video supports the figures shown in table shown above for the stated cable types and distances. Installation of cable types and distances that are outside of the scope of this table are undertaken solely at the installers’...
  • Page 24: Rs 485 Control Code Wiring

    RapidDome/RapidDome Gold MNRDRG120902US RS 485 Control code Wiring The diagram below provides guidelines for correct RS 485 wiring. Pay particular attention to the shield connections. Junction boxes are to be supplied by the installer. Page 24 of 51...
  • Page 25: Unpacking And Pre Assembly

    They also contain static sensitive devices. Units must always be handled carefully and with anti static precautions. The RapidDome/RapidDome Gold units are supplied as pre assembled units that require the minimum of additional work to prepare for final installation. Internal 5”units: •...
  • Page 26: Acrylic Cleaning

    RapidDome/RapidDome Gold MNRDRG120902US Great care must be taken when handling mirrored acrylics. The acrylic will sustain permanent irreparable damage if it is handled on the inside surface. Acrylic Cleaning Periodic cleaning of acrylics will be required in all environments. A soft cloth and methylated spirits or proprietary foam cleaner will suffice for most applications.
  • Page 27 RapidDome/RapidDome Gold MNRDRG120902US Mount Installation The RapidDome/RapidDome Gold units have a full range of mounting options for both internal and external applications. Depending on the type of RapidDome/RapidDome Gold that you have ordered it will be supplied as a complete kit, including mount or as a Dome assembly with the mount supplied separately.
  • Page 28: Cable Termination External Units

    RapidDome/RapidDome Gold MNRDRG120902US Cable Termination External Units All installation wiring connections are made to the connector blocks that are located on the PCB housed within the mount assembly. Wiring tips Follow this process for easy cable terminations. • Pull the terminal blocks out of the sockets on the PCB (External only) •...
  • Page 29 RapidDome/RapidDome Gold MNRDRG120902US External Wiring PCB Details Connectors 1,2,3,4 and 5 are for system wiring. The other connectors are used for wiring through the plug and play assembly. Page 29 of 51...
  • Page 30: External Wiring Pcb Details

    Composite video output connection CON4 RapidDome/RapidDome Gold power - VS 24 vac power supply to RapidDome/RapidDome Gold (negative connection when using 12 volt dc power supply) + VS 24 vac power supply to RapidDome/RapidDome Gold (positive connection when using 12 volt dc power supply)
  • Page 31: Internal Wiring Pcb Details

    RapidDome/RapidDome Gold MNRDRG120902US Internal Wiring PCB Details Internal PCB Wiring Connections Table CON 1 Video out NVT + Twisted pair CAT5 NVT video connection positive pole NVT - Twisted pair CAT5 NVT video connection negative pole VIDEO Composite video output connection...
  • Page 32: Internal Alarm Connections

    One or two wiring looms are provided with the RapidDome/RapidDome Gold, depending on whether the unit is a RapidDome or a RapidDome Gold unit. Each wiring loom has an RJ 45 connector that is pre wired to “tails”.
  • Page 33: Internal Alarm Cable Details

    RapidDome/RapidDome Gold MNRDRG120902US Internal Alarm Cable Details Alarm cables are supplied with a standard color coding Pin orientation is shown on the picture below. Connection Table For Alarm Inputs and Outputs Con 1 Con 2 Colour (Orbiter Gold only) Alarm input 5 N/O...
  • Page 34: Alarm Output Control

    RapidDome/RapidDome Gold MNRDRG120902US Alarm Output Control The alarm output functionality of the RapidDome/RapidDome Gold is controlled by switch 8 of the DILSW2 array. DILSW2 array Switch 8 “ON”. This is the factory shipped default condition. All Orbiter head alarm functionality is enabled.
  • Page 35: Alarms To The Rapiddome/Rapiddome Gold Head Functionality

    When the timer expires the following steps are taken. 4) The RapidDome/RapidDome Gold returns to it’s pre alarm state. This may be a tour, preset or just a fixed position. 5) The alarm output relay 1 becomes inactive and changes back to the non-alarm state.
  • Page 36: Cable Termination Internal Units

    PCB housed within the mount assembly. Alarm connections are plugged into the RJ 45 alarm sockets that are located on the upper cover of the RapidDome/RapidDome Gold. If alarm devices are being connected to the Dome via...
  • Page 37: Plug And Play Fitting

    RapidDome/RapidDome Gold MNRDRG120902US Plug And Play Fitting Apply power to the mount that is to be worked on before inserting the RapidDome/RapidDome Gold unit. Page 37 of 51...
  • Page 38: Rapiddome/Rapiddome Gold Initialization Process

    RapidDome/RapidDome Gold MNRDRG120902US RapidDome/RapidDome Gold Initialisation Process When a RapidDome/RapidDome Gold is first powered up it will go through an initialisation procedure, under which all functions are tested and the pan, tilt and lens sensors are located. This will always happen, regardless of the control code control method.
  • Page 39 MNRDRG120902US Power Up Sequence For Coaxial Control code Control No set up of the RapidDome/RapidDome Gold is necessary for ADEMCO Video Coaxial control code. The control code mode is auto sensing, if no RS 485 connection is sensed the RapidDome/RapidDome Gold will operate via coaxial control code.
  • Page 40: Address Selection

    RapidDome/RapidDome Gold MNRDRG120902US RS 485 Twisted Pair Control code Set Up There are three areas that require set up on the RapidDome/RapidDome Gold inner for twisted pair control code operation: • The RapidDome/RapidDome Gold address. • RS 485 termination selection.
  • Page 41: Addressing Scheme

    RapidDome/RapidDome Gold MNRDRG120902US Addressing Scheme The ADEMCO Video addressing scheme is calculated as “binary plus one”, which is the binary value of the DILSW 2 settings plus one. The first seven switches of the DILSW2 array represent a binary value;...
  • Page 42: Rs 485 Address Examples

    This is calculated as 64+32+16+8+4+2+1 = 127 which is the setting for DILSW2 array with all seven address switches “off”. Because the ADEMCO Video address scheme is binary value +1 the actual total is 127 + 1 = 128. Pictorial Examples...
  • Page 43: Ademco Video Address Table (First 32 Addresses)

    RapidDome/RapidDome Gold MNRDRG120902US Binary value = 1+2+4+8=16=32=64 = 127 ADEMCO Video value: 127+1=128 VCL Address Table (First 32 addresses) Binary ADEMCO Value (16) (32) (64) Video Address Page 43 of 51...
  • Page 44: Rs 485 Termination Settings

    Theory for RS 485 termination is covered on page 20 of this manual, but here is a basic pair of rules: • If the RapidDome/RapidDome Gold is at the end of a daisy chain it should be terminated. • If the RapidDome/RapidDome Gold is at any location along a daisy chain (but not at the end) it should not be terminated.
  • Page 45: Rs 485 Termination Selection

    RapidDome/RapidDome Gold MNRDRG120902US RS 485 Termination Selection The RS 485 termination is selected on /off by the position of the dual shunt link LK2. Termination is selected hi / low by the position of the dual shunt link LK1 The links are also labelled TPTERM as shown below.
  • Page 46 Power Up Sequence For RS 485 Twisted Pair Control code Control • Set the RapidDome/RapidDome Gold RS 485 address. • Set the RS 485 termination. • Insert the RapidDome/RapidDome Gold into the fully wired up and powered plug and play fitting. • The RapidDome/RapidDome Gold will go through the normal initialisation routine.
  • Page 47: Control Code Protocol Selection

    RapidDome/RapidDome Gold MNRDRG120902US Control code Protocol Selection The RapidDome/RapidDome Gold control code protocol is defined by the setting of the switch array marked as DILSW1. DILSW1 array Control code Protocol Selection Table Protocol Selected ADEMCO Video (Factory default setting) Pelco D...
  • Page 48 RapidDome/RapidDome Gold MNRDRG120902US Compliance Information USA This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: This device may not cause harmful interference. This device must accept any interference received, including interference that may cause undesired operation.
  • Page 49 RapidDome/RapidDome Gold MNRDRG120902US Compliance Information Canada This Class A digital apparatus complies with Canadian ICES-003. Cet appareil numérique de la classe A est conforme à la norme NMB-003 du Canada. Page 49 of 51...
  • Page 50: Equipment Repair Procedure

    No equipment will be accepted at the factory without a valid RA number. Please mark this number clearly and visibly on the outer packaging of the returning product. Please return the product freight prepaid to: ADEMCO Video Product Return Attn: RAC#_________ 165 Eileen Way Syosset, NY 11791...
  • Page 51 RapidDome/RapidDome Gold MNRDRG120902US Page 51 of 51...

This manual is also suitable for:

Rapiddome gold

Table of Contents