Summary of Contents for BRUEL & KJAER LAN-XI

  • Page 2 2015 Copyright © Brüel & Kjær. All rights reserved...
  • Page 3: Table Of Contents

    • Connection and Setup......................................6 • LAN-XI Firmware Update ....................................8 • Connecting to a Front end with Front-end Setup ............................. 10 • Installing a LAN-XI Notar License ..................................12 • Using LAN-XI Notar......................................13 • Changing Module Front Panels ..................................15...
  • Page 5: Configuration - Single Module With Battery

    ‡ micro-SD card with adaptor (using local storage). Shown: 16 GB Micro-SD Card with Mini-SD Adaptor UL-1018 Included with LAN-XI Module Types 3050, 3052, 3053, 3056, 3057, 3160 and 3161 † Included with Battery Module for LAN-XI Type 2831-A ‡...
  • Page 6: Configuration - Single Module Without Battery

    ‡ micro-SD card with an adaptor Shown: 16 GB Micro-SD Card with Mini-SD Adaptor UL-1018 150425 Included with LAN-XI Module Types 3050, 3052, 3053, 3056, 3057, 3160 and 3161 † Included with Battery Module for LAN-XI Type 2831-A ‡ Older modules have a mini-SD slot, newer modules a micro-SD slot...
  • Page 7: Configuration - Multiple Modules In A Frame

    Type 3160-A-022 – 1-ch. Input + 1-ch. Output Module LAN-XI 204.8 kHz Type 3161-A-011 2) Insert up to two Battery Module for LAN-XI Type 2831-A in the rightmost slots. 3) Connect a mains power cable. 4) Connect a network cable: –...
  • Page 8: Connection And Setup

    DHCP network as explained above. Open 3) Press and hold the Control button for 5 seconds while the cursor the LAN-XI module’s web page, by typing the IP address from the is on ‘LAN reset’ in the display menu.
  • Page 9 Setup of LAN-XI Notar If your LAN-XI Notar was ordered at the same time as the LAN-XI module, then the LAN-XI Notar firmware and license will have been installed and tested at Brüel & Kjær. Go to “Using LAN-XI Notar” on page 13.
  • Page 10: Lan-Xi Firmware Update

    Connect to the module’s home page by typing the IP address from the front of the module into your web browser and click Downloads. 2) Select LAN-XI under Step 1 and LAN-XI Software Updates under Step 2. 3) Click on the latest firmware link to download the firmware to any...
  • Page 11 4) On your module’s home page, click Firmware. 5) Click Browse... and navigate to the file. 6) Click Start update.
  • Page 12: Connecting To A Front End With Front-End Setup

    CONNECTING TO A FRONT END WITH FRONT-END SETUP To connect to one or more front ends: 1) Launch Front-end Setup. 2) If your firewall program tells you that the program is being – preferably in all types of domain (Home, blocked, click Unblock Work, Public) 3) Click Browse Devices.
  • Page 13 8) Click Apply and Save Configuration. If it is not possible to download the latest firmware from the front end’s home page (see “LAN-XI Firmware Update” on page 8), use the following procedure to install the firmware version that was included in your PULSE installation: 9) Click Firmware.
  • Page 14: Installing A Lan-Xi Notar License

    INSTALLING A LAN-XI NOTAR LICENSE 1) Using the media on which you received the license key, open the license.txt file in any word processing application or text editor and copy the text string. 2) Connect to the module’s home page and click Licenses in the menu to enter the recorder.
  • Page 15: Using Lan-Xi Notar

    USING LAN-XI NOTAR 1) Open the front-end’s web page from any browser and click Open supported on Types 3050, 3160, 3052 and recorder application ( 3053) 2) Click Create new>> in the recordings window.
  • Page 16 5) Stop recording either by clicking Stop on the module’s web page or by pressing the Control button below the module’s display. 6) Click Close recorder application when done to return the LAN-XI module to its normal operating mode, or select Exit Recorder in the menu on the module display.
  • Page 17: Changing Module Front Panels

    CHANGING MODULE FRONT PANELS 1) Remove the hex wrench from its holder at the top right side of the module. 2) Loosen the screw in the hole at the bottom of the front panel (see figure). 3) Remove the front panel, bottom first. 4) Insert the new panel, top first.
  • Page 18: Using Power Over Ethernet (Poe)

    USING POWER OVER ETHERNET (POE) LAN-XI modules can receive power over their ethernet cables from PoE switches, such as PULSE Measurement System Switch UA-0265 (8-port LAN-switch with PoE and PTPv2 Support), or from PoE injectors, such as the ZyXEL® PoE-12 Power over Ethernet injector shown.
  • Page 19 Brüel & Kjær and all other trademarks, service marks, trade names, logos and product names are the property of Brüel & Kjær or a third-party company.
  • Page 20 HEADQUARTERS: Brüel & Kjær Sound & Vibration Measurement A/S DK-2850 Nærum · Denmark Telephone: +45 7741 2000 · Fax: +45 4580 1405 · www.bksv.com · info@bksv.com Local representatives and service organizations worldwide...