[ENG] NetPing Infra Red Universal Remote Control 3802, User guide -[ENG] [IR3801] Settings Reset to Default Values

[ENG] [IR3801] Settings Reset to Default Values

To reset parameters carry out these steps:
turn off the power to the device;
press RES button;
turn on the power;
release the button 5-10 seconds after turning on the power.
 If you carried out these steps successfully, the LED will blink, indicating the parameters are being reset.
The device has the following parameters by default:
Username: visor
Password: ping
IP-address: 192.168.0.100
Subnet mask: 255.255.255.0
Gate (gateway): has not been set
SNMPcommunity: SWITCH
MAC-address: 00 a2 xx xx xx xx
Here xx xx xx xx is equal to the serial number of the device. Thus, all devices after production have a unique MAC
address.
After resetting the parameters to the default values, it is necessary to perform the initial configuration of the device.