Advertisement

ECO S W IM 10 0, 2 0 0 & 300
USER
MANUAL

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ECO SWIM 100 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Maytronics ECO SWIM 100

  • Page 1 ECO S W IM 10 0, 2 0 0 & 300 USER MANUAL...
  • Page 2: Important Safety Information

    Should you require additional information hazard. or further assistance, do not hesitate to contact your local Eco Swim representative or visit our website www.maytronics.com.au. WARNING Do not operate the electrolytic cell without proper flow or water circulation as this may cause damage to the unit.
  • Page 3: Table Of Contents

    Notice of Liability: While every effort has been taken Maintenance ......................21 to ensure the accuracy of this document, neither Maytronics Australia nor any of its official representative shall have any liability to any person or entity with respect to Water Chemistry (Balancing Information) ..........
  • Page 4: Control Unit Features

    Control Unit Features ES100, ES200, ES300 units FEATURES Ozone Run Indicator Air Filter *Ozone upgraded model only *Ozone upgraded model only Chlorine Cell Output Display Ozone Output *Ozone upgraded model only Fuse pH Drive Socket (12V plug) Sanitation Switch Positive Cell Lead (Red) Master Switch Negative Cell Lead (Black) Chlorine Cell Output Control (0-99)
  • Page 5: Installation

    Installation Guide ES100, ES200, ES300 control units These products must be installed by a qualified installer CHLORINATOR CELL CARTRIDGE MEDIA FILTER FILTER from PUMP pool return to pool INSTALLATION Step 1: Mount Eco Swim control unit a maximum of 1.5 meters from the filter and chlorine cell.
  • Page 6: Important Notes

    CHLORINATOR CHLORINATOR Step 5: CELL CELL Leave plumbing to cure for a 24-hour period for best results. MEDIA FILTER Step 6: Set timer on Eco Swim system to recommended run time for pool size CARTRIDGE FILTER and environment (refer to page 16).
  • Page 7: Operations

    New Pools • It is essential that the new pool is balanced correctly. Consult your pool builder on how do this or Maytronics can provide information to do this. • You can find the water chemistry parameters on p. 21 of this manual.
  • Page 8 Sanitation Switch Checking Chlorination Output Ozone Swim 1000, 2000 and 3000 series User Manual – JULY 2017 ENG rev 2.0 The system will not operate. The chlorine cell output controller regulates the amount of chlorine production relevant Auto The time clock will automatically switch your pool to the position it has been set to.
  • Page 9: Maintenance

    Maintenance Electrode (Cell) Cleaning Although you have a reverse cycle (automatic cell cleaning) system, it is recommended from time to time that the cell be checked for any accumulation of calcium or other deposits that may have built up. We recommend cleaning the cell once or twice a year subject to your pool’s application and location.
  • Page 10: Warranty

    Year • 5 year pro-rata warranty of chlorinator cell. (2 Year Full, year 3, Warranty 4, 5 Pro-rata). Activate your Eco Swim warranty by registering at: maytronics.com.au/support/registration WARRANTY U s e r M a n U a l...
  • Page 11: Troubleshooting

    Troubleshooting Fault Potential Causes Action Required Cell output display flashing • Pump turned off or • Ensure pump is on disconnected “Pb” continuously (no water • Valves closed • Ensure correct valves are open flow) • Gas sensor wire at cell •...
  • Page 12 maytronics.com.au...

This manual is also suitable for:

Eco swim 200Eco swim 300

Table of Contents

Save PDF