Upgrade kit (unregulated)

Advertisement

Quick Links

1. Make sure the Shop Pro FXP is disconnected from
the 120VAC power source.
2. Remove the vent cap and drain the filtration unit
completely then close the drain valve. Leave the
cap off until instructed to replace it.
DAVCO Technology, LLC
1600 Woodland Drive, Saline, MI 48176-1629
UPGRADE KIT (UNREGULATED)
3. Replace the drain hose in the clip.
4. Loosen the five ¼" headed bolts slightly until the
motor cover slides to the left and remove the cover.
5. Remove the two ½" headed pump bracket bolts/
washers and discard.
800-328-2611
1
SHOP PRO FXP 95
F3234 REV B
www.davco.com
May 3, 2019

Advertisement

loading
Need help?

Need help?

Do you have a question about the SHOP PRO FXP 95 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Davco SHOP PRO FXP 95

  • Page 1 SHOP PRO FXP 95 UPGRADE KIT (UNREGULATED) 1. Make sure the Shop Pro FXP is disconnected from 3. Replace the drain hose in the clip. the 120VAC power source. 4. Loosen the five ¼" headed bolts slightly until the 2. Remove the vent cap and drain the filtration unit motor cover slides to the left and remove the cover.
  • Page 2 SHOP PRO FXP 95 UPGRADE KIT (UNREGULATED) 6. Slide the pump and bracket to the right as shown. 9. Cut the hoses as close to the fittings as possible and drain the fuel from the hoses. 7. Remove the Lovejoy couple from the motor and discard.
  • Page 3 SHOP PRO FXP 95 UPGRADE KIT (UNREGULATED) 11. Remove the discharge (pressure) hose from the 13. Place a rag on motor to catch residual fuel from Shop Pro and set it aside for later use. filtration unit. 14. Install the 5/16" set screw into the motor coupler.
  • Page 4 SHOP PRO FXP 95 UPGRADE KIT (UNREGULATED) 16. Install the new pump bracket onto the Shop Pro 19. Adjust the coupler depth so there is ~1/8" air gap cart as shown using the new bolts and washers – between the face of the couple and the face of the hand tighten only.
  • Page 5 SHOP PRO FXP 95 UPGRADE KIT (UNREGULATED) 22. Lubricate one end of the 20" suction hose and 25. Apply liquid thread sealant to threads on hose end install it on the outlet of the filtration unit as shown. and install on fuel pump as shown.
  • Page 6: Black Wire

    SHOP PRO FXP 95 UPGRADE KIT (UNREGULATED) 27. Remove the grounding nut as needed. 30. Loosen the access plate screws slightly and re- move the plate from motor. 28. Loosen the motor clamp bolts slightly until the motor pivots in the cradle freely.
  • Page 7 SHOP PRO FXP 95 UPGRADE KIT (UNREGULATED) 33. Bundle the power cord back into the electrical 36. Open both valves as shown. cavity and replace the access panel. 37. Connect an extension cord to the power box on 34. Rotate the motor on pivot so the electrical cord is the back of the cart.
  • Page 8 SHOP PRO FXP 95 UPGRADE KIT (UNREGULATED) 40. Fill the Shop Pro filtration unit with clean diesel fuel 43. Install the motor cover onto cart and tighten the and replace the vent cap. five ¼" headed bolts. 44. Remove the existing front product label and re- 41.
  • Page 9 UPGRADE KIT (UNREGULATED) 46. Remove the existing hanging operation and safety tags on the main cart handle and replace as shown. 47. The Shop Pro FXP 95 PSI upgrade is now com- plete. F3234 REV B DAVCO Technology, LLC 1600 Woodland Drive, Saline, MI 48176-1629 800-328-2611 www.davco.com...