rba RBA2770 Series Installation, Operation And Maintenance Instructions page 2

Wall mounted 'compact' water coolers

Advertisement

Components Supplied by Others
Wall fasteners for signage mounting
Pipe sealant or Teflon tape for sealing water connections
40mm trap [Due to cold waste water, we recommend the trap supplied by installer be insulated to prevent excessive
condensation]
Hydraulic Requirements
Operating pressure:
200-500kPa
Inlet:
G1/2B
Outlet:
40mm BSP Waste
Water Temp:
4o - 32o
Provide 102mm minimum clear space on fixture sides to allow for proper ventilation through cabinet louvers.
Rough-in and Dimensions
Prior to roughing-in consult with local, state, and federal codes for proper mounting height. Installation to be done in
accordance with AS/NZS 3500.1 and AS/NZS 3500.2
306
153
51
C L
25
Electric
Outlet
63
464
Air Flow
FRONT VIEW
2 of 4
INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS
Waste location
Supply 15mm BSP
851
730
Finished Floor
SYDNEY | MELBOURNE | BRISBANE | PERTH | AUCKLAND
Australia 1300 788 778 www.rba.com.au | New Zealand 0800 722 111 www.rbagroup.co.nz
Trap (not furnished)
317
1045
Orifice
Height
1016
Rim
Height
SIDE VIEW