Summary of Contents for Cistermiser EasyflushEVO

  • Page 1 Easyflush EVO 1.5" EVO 2" EVO CISTERN...
  • Page 2: Supplied Parts

    15 IR activation label walk & wave 16 Mains transformer 17 Clamp plate fixing screw 18 Mains transformer fixing screws 19 Battery case 20 Sticky pad 2 | cistermiser.co.uk Have a question? Call our customer support team on 0118 969 1611...
  • Page 3: Optional Extras

    Mains transformer fixing screws Battery case Sticky pad Optional extras Infrared Configuration Unit (ICU) Multi Product Power Supply Unit (PSUC) Side Front Adaptor (SFA) Extension cable (IFS/10) Have a question? Call our customer support team on 0118 969 1611 cistermiser.co.uk | 3...
  • Page 4: Valve Operation

    If a flush is activated while the cistern is refilling, the sensor will remember the flush request and only activate when the cistern is full (to set refill time see page 12). This is indicated by three rising green LEDs. 4 | cistermiser.co.uk Have a question? Call our customer support team on 0118 969 1611...
  • Page 5: Valve Installation

    Fit EVO Flush Valve to Outlet EVO CISTERN only). Ensure in cistern. Secure by rotating cistern is mounted level. clockwise. ✗ ✗ ✔ ✔ WARNING: Cistern must be level! Have a question? Call our customer support team on 0118 969 1611 cistermiser.co.uk | 5...
  • Page 6 To adjust height of Easyflush Lift or lower upper body to adjust Rotate anticlockwise to lock. Flushing Valve rotate upper body height. clockwise to release. 6 | cistermiser.co.uk Have a question? Call our customer support team on 0118 969 1611...
  • Page 7: Sensor Positioning

    Walkaway version only. Minimum distance applies. If x (see diagram) is less than 12cm it is recommended that the Hand Activation is disabled. Refer to section 9. Have a question? Call our customer support team on 0118 969 1611 cistermiser.co.uk | 7...
  • Page 8 For holes between 40 and 50mm contact Contact Cistermiser for further details or order Cistermiser for a hole adapter. A hole diameter online at www.cistermiser.co.uk larger than 50mm is a non standard installation.
  • Page 9: Power Connections

    Multiple power connections for Easyflush If installing multiple Cistermiser products, the PSUC Multi Product Power Supply Unit is available as an accessory. Contact Cistermiser for more details. Multi product power supply unit (Not supplied, contact Cistermiser for further details).
  • Page 10: Testing And Commissioning

    For chemical water treatment. If the water system has been treated with chemical dosing, ensure the system is thoroughly flushed before fitting any Cistermiser products. Concentrated chemicals in dead legs can damage the product and result in failure. If the water is treated with Chlorine Dioxide (ClO2), ensure concentration levels are maintained below 5ppm.
  • Page 11: Maintenance

    8. Maintenance Fill valve (supplied with EVO CISTERN only): Periodically rinse the inlet filter and valve diaphragm. If the diaphragm is damaged contact Cistermiser for a replacement. You may rinse the filter or the membrane to maintain your fill valve.
  • Page 12: Factory Settings

    Mains power supply: 100-250v AC 50/60Hz 1A MAX Fill Valve (supplied with EVO CISTERN only) Minimum working pressure: 0.1 bar Maximum working pressure: 10 bar 12 | cistermiser.co.uk Have a question? Call our customer support team on 0118 969 1611...
  • Page 13: Component Dimensions

    10. Component dimensions EVO 1.5 & EVO 2 119.5 EVO1.5 - 1.5" outlet EVO2 - 2.0" outlet EVO CISTERN 6 LITRE CRITICAL WATER LEVEL Have a question? Call our customer support team on 0118 969 1611 cistermiser.co.uk | 13...
  • Page 14 Stand at the distance from the sensor you would Sensor distance like to set as maximum range. Wait 8 seconds is now set. until constant triple green LEDs show. 14 | cistermiser.co.uk Have a question? Call our customer support team on 0118 969 1611...
  • Page 15 LEDs will show. The refill time has green now been set. After configuration the LEDs will flash triple amber, giving opportunity to re-enter configuration mode. Have a question? Call our customer support team on 0118 969 1611 cistermiser.co.uk | 15...
  • Page 16: Button Descriptions

    12. Infrared Configuration Unit (ICU) guide NOTE: Not supplied but available from Cistermiser or any major plumbing merchant. Button descriptions Activates cleaning mode Activates ICU configuration mode Decreases setting Increases setting Checks the setting being altered Saves changes and exits ICU configuration mode...
  • Page 17 Save setting and exit ICU configuration by pressing pressing the button. button. Exit without saving by pressing the button. Exit without saving by pressing the button. Have a question? Call our customer support team on 0118 969 1611 cistermiser.co.uk | 17...
  • Page 18: Frequently Asked Questions

    Low or no battery power; change batteries. If operated by mains not at all when a hand is power, check wiring then contact Cistermiser. placed in front of it. Check fill valve and flush valve are aligned with water level...
  • Page 19 Sensor covered or heavily scratched. Uncover or polish out LEDs scratches. Sensor flashing double red Servo motor obstruction or wiring fault - Call Cistermiser for advise. top LEDs Cistermiser product warranty and extended warranty Cistermiser products are guaranteed for The warranty on Cistermiser products can 12 months from the date of manufacture.
  • Page 20 Commissioning check-list Easyflush The warranty on Cistermiser products can be extended within one year of date of manufacture, at no cost, to three years from the date of installation. Once YEAR the valve has been installed, complete the product commissioning checklist below to demonstrate compliance with the installation instructions.
  • Page 21 Notes Have a question? Call our customer support team on 0118 969 1611 cistermiser.co.uk | 21...
  • Page 22 Notes 22 | cistermiser.co.uk Have a question? Call our customer support team on 0118 969 1611...
  • Page 23 Have a question? Call our customer support team on 0118 969 1611 cistermiser.co.uk | 23...
  • Page 24 The range is used in domestic, commercial combimate.co.uk and industrial applications worldwide. keraflo.co.uk Cistermiser Limited Unit 1, Woodley Park Estate, 59-69 Reading Road, Woodley, Reading, Berkshire RG5 3AN t: +44 (0) 118 969 1611 e: sales@cistermiser.co.uk cistermiser.co.uk...

Table of Contents