Advertisement

CEP081C - 8,000
CEP081C - 8,000
CEP101C - 10,000
CEP101C - 10,000

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the CEP081C and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Coast-Air CEP081C

  • Page 1 CEP081C - 8,000 CEP081C - 8,000 CEP101C - 10,000 CEP101C - 10,000...
  • Page 2: Table Of Contents

    Installation and Operation Instruction Manual 8,000 - 10,000 CONTENTS IMPORTANT SAFEGUARDS IMPORTANT - GROUNDING METHOD ELECTRICAL CONNECTIONS DESCRIPTION INSTALLATION INSTRUCTIONS DESCRIPTION OF THE DISPLAY SCREEN REMOTE CONTROL MANUAL WATER DRAINAGE METHOD CLEANING TROUBLESHOOTING www.coastair-ac.com...
  • Page 3: Important Safeguards

    Installation and Operation Instruction Manual 8,000 - 10,000 IMPORTANT SAFEGUARDS ● This appliance is for household use only. ● Disconnect the appliance from its power source during service and when replacing parts and cleaning. ● Please note: Check the nameplate for the type of refrigerant gas used in your appliance.
  • Page 4 Installation and Operation Instruction Manual 8,000 - 10,000 IMPORTANT SAFEGUARDS ● Do not clean the unit with water. Water can enter the unit and damage the insulation, creating a shock hazard. If water enters the unit, unplug it immediately and contact Customer Service.
  • Page 5: Important - Grounding Method

    Installation and Operation Instruction Manual 8,000 - 10,000 IMPORTANT - GROUNDING METHOD This product is factory equipped with a power supply cord that has a three-pronged grounded plug. It must be plugged into a mating grounding type receptacle in accordance with the National Electrical Code and applicable local codes and ordinances.
  • Page 6 Installation and Operation Instruction Manual 8,000 - 10,000 ELECTRICAL CONNECTIONS PREFERRED GROUNDING METHOD TEMPORARY GROUNDING METHOD (Use of adapter plugs is not permitted in Canada) Ensure proper Ensure proper ground exists ground exists before use. before use. RECOMMENDED GROUND METHOD For your personal safety, this appliance must be grounded.
  • Page 7: Description

    Installation and Operation Instruction Manual 8,000 - 10,000 DESCRIPTION 1. Control panel 2. Handle(both side) 3. Castors 4. Deflector 5. Intake grill 6. Air outlet grill 7. Intake grill 8. Power cable 9. Plug fixer 10. Middle condenser drain 11. Condenser drain ACCESSORIES QUANTITY PARTS...
  • Page 8: Installation Instructions

    Installation and Operation Instruction Manual 8,000 - 10,000 INSTALLATION INSTRUCTIONS EXHAUSTING HOT AIR In the Cool Mode the appliance must be placed close to a window or opening so that the warm exhaust air can be ducked outside. First position unit on a flat floor and make sure there's a minimum of 17.7"...
  • Page 9 Installation and Operation Instruction Manual 8,000 - 10,000 INSTALLATION INSTRUCTIONS WINDOW SLIDER KIT INSTALLATION 1.Parts: A) Panel B) Panel with one hole C) Screw to lock window kit in place 2.Assembly: Slide Panel B into Panel A and size to window width.
  • Page 10 Installation and Operation Instruction Manual 8,000 - 10,000 INSTALLATION INSTRUCTIONS 1. Cut the foam seal(adhesive type) to the proper length and attach it to the window sash. 2. Attach the window slider kit to the window sash. Adjust the length of the window slider kit according to the width of window.
  • Page 11 Installation and Operation Instruction Manual 8,000 - 10,000 INSTALLATION INSTRUCTIONS LOCATION ● The unit should be placed on a firm foundation to minimize noise and vibration. For safe and secure positioning, place the unit on a smooth, level floor strong enough to support the unit. ●...
  • Page 12: Description Of The Display Screen

    Installation and Operation Instruction Manual 8,000 - 10,000 DESCRIPTION OF THE DISPLAY SCREEN 3 4 5 1. Timer button A .Cool symbol 2. Fan button B. Dehumidify symbol 3. Increase button C. Fan symbol 4. Display screen D. High Speed Fan symbol 5.
  • Page 13 Installation and Operation Instruction Manual 8,000 - 10,000 DESCRIPTION OF THE DISPLAY SCREEN COOL mode Ideal for hot muggy weather when you need to cooling and dehumidify the room. To set this mode correctly: ● Press the “ ” button a number of times until the “Cool” symbol light appears. △...
  • Page 14 Installation and Operation Instruction Manual 8,000 - 10,000 DESCRIPTION OF THE DISPLAY SCREEN DRY mode Ideal to reduce room humidity (spring and autumn, damp rooms rainy periods, etc). Before using the dry mode, the appliance should be prepared in the same way as for cool mode, with the air exhaust hose attached to enable the moisture to be discharged outside.
  • Page 15 Installation and Operation Instruction Manual 8,000 - 10,000 DESCRIPTION OF THE DISPLAY SCREEN Switch the unit of temperature Hold on “△” and ”▽” button three seconds by the same time, then you can change the unit of temperature. For example: Before change, in cool mode, the screen display like Fig.1.
  • Page 16: Remote Control Manual

    Installation and Operation Instruction Manual 8,000 - 10,000 REMOTE CONTROL MANUAL On/Off button Fan speed button Increase button Mode button Decrease button Swing button Timer button Sleep button Unit Switch button NOTE: This serial model have no auto swing function. √...
  • Page 17 Installation and Operation Instruction Manual 8,000 - 10,000 REMOTE CONTROL MANUAL INSERTING OR REPLACING THE BATTERIES ● Remove the cover on the rear of the remote control; ● Insert two "AAA" 1.5V batteries in the correct position (see instructions inside the battery compartment);...
  • Page 18 Installation and Operation Instruction Manual 8,000 - 10,000 REMOTE CONTROL MANUAL FAN mode When using the appliance in this mode, the air hose does not need to be attached. ● Press the “ ” button a number of times until the “Fan” symbol light appears. ●...
  • Page 19 Installation and Operation Instruction Manual 8,000 - 10,000 REMOTE CONTROL MANUAL SWING function NOTE: This serial unit have no auto swing function. Please adjust the deflectors by manual to the suitable position. A: Horizon deflector B: Vertical deflector SLEEP function This function is useful for the night as it gradually reduces operation of the appliance.
  • Page 20 Installation and Operation Instruction Manual 8,000 - 10,000 REMOTE CONTROL MANUAL SETTING THE TIMER ● This timer can be used to delay the appliance start up or shutdown, this avoids wasting electricity by optimizing operating periods. Programming start up ● Turn on the appliance, choose the mode you desire, for example cooling, (75℉)24℃ and high fan speed.
  • Page 21 Installation and Operation Instruction Manual 8,000 - 10,000 REMOTE CONTROL MANUAL TIPS FOR CORRECT USE Fig.21 To get the optimal performance from your appliance, follow these recommendations: ● Close the windows and doors in the room to be air conditioned (Fig.
  • Page 22: Water Drainage Method

    Installation and Operation Instruction Manual 8,000 - 10,000 WATER DRAINAGE METHOD When there is excess water condensation inside the unit, the appliance stops running and shows “ ” (FULL TANK as mentioned in SELF-DIAGNOSE). This indicates that the water condensation needs to be drained using the following procedures: Fig.24) Manual Draining 1 .Unplug the unit from power source.
  • Page 23 Installation and Operation Instruction Manual 8,000 - 10,000 WATER DRAINAGE METHOD Middle drainage When unit running in Dry mode, you can choose the way below to drainage. 1 .Unplug the unit from the power source. 2. Remove the drain plug(Fig.A). While doing this operation some residual water may spill so please have a pan to collect the water.
  • Page 24: Cleaning

    Installation and Operation Instruction Manual 8,000 - 10,000 CLEANING Before cleaning or maintenance, turn the appliance off by pressing the button on the control panel or remote control, wait for a few minutes then unplug from the mains socket. CLEANING THE CABINET You should clean the appliance with a slightly damp cloth then dry with a dry cloth, may not used water to wash appliance.
  • Page 25: Troubleshooting

    Installation and Operation Instruction Manual 8,000 - 10,000 TROUBLESHOOTING ROOM CONDITIONS Temperature of room 64℉-95℉ (18 35℃)(Cooling) ℃- Temperature of room 50℉-77℉ (10℃-25℃)(Heating) PROBLEM CAUSE SOLUTION The appliance ● There is no current ● Check the power supply does not come on ●...
  • Page 26 Installation and Operation Instruction Manual 8,000 - 10,000 TROUBLE SHOOTING The appliance ● ● The internal compressor safety Wait. This delay is part of normal operation device prevents the appliance does not operate for from being restarted until three about three minutes minutes have elapsed since it after restarting it was last turned off...
  • Page 27 Installation and Operation Instruction Manual 8,000 - 10,000 · 25 · www.coastair-ac.com...
  • Page 28 Installation and Operation Instruction Manual 8,000 - 10,000 5/2022 11/2021 www.coastair-ac.com...

This manual is also suitable for:

Cep101c

Table of Contents