Damage
To prevent damage:
• Do not stand or support yourself on the base, top,
expansion module, fan or fins.
• Pull the mains plug – not the power cord.
• Use a plate to equalize the pressure from the fermenter.
Cleaning
• Switch off the appliance.
• Pull out the mains plug or switch off the fuse.
• Do not use abrasive, chloride or acidic cleaning agents or
solvents.
• Do not use scouring or abrasive sponges.
• Never clean any parts in the dishwasher.
• Do not clean the appliance with metal objects.
• Clean the appliance with a soft cloth, lukewarm water, and
a little pH-neutral washing-up liquid.
• Do not clean the display or cooling/heating unit with
liquid or a wet cloth.
Intended use
Use this appliance:
• Only for foods and beverages
• Only according to these operating instructions.
Environmental protection
Packaging:
All materials are environmentally safe and recyclable:
• Dispose of packaging in an environmentally friendly
manner.
• Please ask your dealer or inquire at your local authority
about current means of disposal.
Old appliances
Valuable raw materials can be reclaimed by recycling old
appliances
• 1. Remove the mains plug. 2. Cut the power cord as close
to the device as possible. 3. Have the appliance disposed
of professionally.
Installation and connection
Important: For electrical installation, carefully follow the
instructions in this manual.
SCAN FOR GUIDES AND MORE INFO
• After unpacking all parts, check for any damage in transit.
Do not connect if it is damaged. Immediately report any
transport damage to the dealer from whom you
purchased the appliance. Keep the packaging.
• Follow the instructions for proper installation.
• Do not place the appliance close to heaters, radiators or
stoves.
• The socket must be freely accessible even after the
appliance has been installed.
• Do not place the temperature probe directly in
water/wort/ beer or other liquids. Use a thermowell when
measuring the temperature inside the fermenter .
Be attentive when testing the Ferminator
If testing the Ferminator before use, it is of key importance to
do this with a fermenter filled with water and place the
temperature probe on the back of it, facing away from the
Cooling/Heating unit. This will ensure the Ferminator is
operating correctly during the test. Neglecting to do this
could result in the Ferminator not operating properly and
giving a faulty result!
Technical Data
• Voltage: 100-240V~1.5A
• Output: 24V ⎓ 4A
• Frequency: 50/60Hz
• Standby power: 1 W
• Max power: 80 W
• Fuse: 10 A - 16 A
• Outside Europe: Check whether the indicated current type
of the appliance corresponds with the values of your
power supply.
Error codes
E1: Inside fan not spinning or spinning too slow
E2: Outside fan not spinning or spinning too slow
E3: High temperature. Temp.beer sensor above 55°C
E4: High temperature. Temp.box sensor above 55°C
E5: Low temperature. Temp.beer sensor below -10°C
E6: Low temperature. Temp.box sensor below -10°C