Installation:
1.
Screw the studded rod (E) into the base of the tap (A).
2.
Screw the hot and cold tail pipes (D&I) into the base of the tap.
3.
Pass the upper seal (B) over the studded rod (E) and tail pipes (D&I) and locate them centrally on the base of the mixertap (A).
4.
Note if the tap is to be fitted to a stainless steel sink then the white triangular plate (C) can be fitted where shown to improve the
stability of the tap.
5.
Place the mixertap (A) onto the sink or worktop and pass the tail pipes (D&I) and studded rod (E) through the taphole. With the tap
in place check that the tail pipes (D&I) meet the hot and cold water feeds. If further adjustment to the plumbing is required do this
now.
6.
Pass the rubber horseshoe (F) and then metal horseshoe (G) over the studded rod (E) and around tail pipes (D&I).
7.
Fasten the fixing nut (H) securely onto the fixing stud (E) fixing the tap into its correct location.
8.
Connect the hot tail pipe (D) to the water supply using ½" BSP x 15mm compression fitting or similar.
9.
Connect the cold tail pipe (I) to the water supply using ½" BSP x 15mm compression fitting or similar.
Key:
Description:
A
Tap body
B
Upper seal
White triangular stabilising plate
C
(for stainless sinks only)
D
Hot flexible tail pipe (1/2" BSP)
E
Fixing stud
F
Rubber horseshoe
G
Metal horseshoe
H
Fixing nut
I
Cold flexible tail pipes (1/2" BSP)
After installation:
Once you have visually checked the installation of the new
tap and all connections, ensure that all other fittings are
closed except the new tap which should be left open.
Turn on your water heating system and ensure that your
mains stopcock is open. Reconnect both the hot and cold
water supplies to this fitting.
Check the function of flow and function of hot, cold and
mixed water.
Turn off the tap and check carefully for any leaks around all
connections on the fitting and adjoining plumbing.
If possible return to the installation after a longer period to
double check for slower leaks. If pressure testing
equipment is available check the installation to the
maximum recommended pressure.
Clean the tap to remove any marks created during
installation as instructed then place a bag over the product
to protect the tap until it is ready for use.
The installation should be periodically checked for damage,
if the property is left unattended for a prolonged period we
recommend isolating water supplies.