Delta Membranes Hi-PowerMaxx2 Installation & Operating Manual

Pump station battery backup

Advertisement

Quick Links

Hi-PowerMaxx2
Installation & Operating Manual
Pump Station Battery Backup

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Hi-PowerMaxx2 and is the answer not in the manual?

Questions and answers

Summary of Contents for Delta Membranes Hi-PowerMaxx2

  • Page 1 Hi-PowerMaxx2 Installation & Operating Manual Pump Station Battery Backup...
  • Page 2 All rights reserved. Contents provided herein must neither be distributed, copied, reproduced, edited or processed for any other purpose, nor otherwise transmitted, published or made available to a third party without express written consent from Delta Membranes. Subject to technical modification without prior notice.
  • Page 3: Table Of Contents

    Health & Safety Unit location Safety General Wiring schematic Wiring a standalone Hi-PowerMaxx2 10.0 Configuring the upper circuit board to the pump/s & alarm 11.0 Setup and configuration of the unit 12.0 Principals of operation 13.0 Battery life & servicing 14.0 Connecting an AlertMaxx2 or Rego1 (if purchased)
  • Page 4: Hi-Powermaxx2 Overview

    Hi-PowerMaxx2 overview The Hi-PowerMaxx2 is designed to provide battery backup to pump stations in the event of a mains failure. They have been specifically designed to meet the requirements of the pump industry. The Hi-PowerMaxx2 has the ability to connect to the AlertMaxx2 high level alarm and Rego1 control panel.
  • Page 5: Health & Safety

    Health & Safety In order to minimise the risk of ill health or accidents when installing and/or servicing pump chambers and associated accessories, workers must be fully trained and competent. The following guidelines will help safeguard matters: • Assessing the risk and working in accordance with the control measures identified. •...
  • Page 6: General

    General The Hi-PowerMaxx2 can supply one or two pumps (not simultaneously) and has been certified for use on: • V4 & V6 The supplies to the pump/s should be separately fused using non-switched fused spurs and not on the same ring mains.
  • Page 7: Wiring A Standalone Hi-Powermaxx2

    Ensure the power switch of the Hi-PowerMaxx2 is in the OFF position. Remove the Hi-PowerMaxx2 lid and place in front of the unit - take care not to damage the cables. Remove the side panels and position the Hi-PowerMaxx2 in the chosen location for installation.
  • Page 8: Configuring The Upper Circuit Board To The Pump/S & Alarm

    10.0 Configuring the upper circuit board to the pump/s & alarm Using the diagram below, set the switches on the upper circuit board according to your systems configuration (figure 3). No Alarm Alarm 1 Pump 2 Pumps Figure 3. Configuring the upper circuit board - Hi-PowerMaxx2...
  • Page 9: Setup And Configuration Of The Unit

    11.0 Setup and configuration of the unit Replace the side panels of the unit, followed by the lid. Replace the fuses to the spurs supplying the unit and turn on the mains power. Check that the pump/s are receiving power (with the unit switched off) by lifting the float switches on the pump/s.
  • Page 10: Principals Of Operation

    After any power failure, the battery is always charged. The battery is also charged and topped up every 21 days. This process can take up to 25 hours for a Hi-PowerMaxx2 to fully charge an empty battery. 13.0 Battery life & servicing The battery has a nominal life span of 3 years and is displayed on the unit with a bL+%.
  • Page 11: Connecting An Alertmaxx2 Or Rego1 (If Purchased)

    14.0 Connecting an AlertMaxx2 or Rego1 (if purchased) The Hi-PowerMaxx2 can be connected to an AlertMaxx2 or Rego1. Battery backup capacity and condition are fed directly to the SideWinder Tech software when connected to the internet. The Hi-PowerMaxx2 is supplied with 3m of 4 core MaxxConnect family cable.
  • Page 12: Alertmaxx2 Wiring Schematic

    16.0 AlertMaxx2 wiring schematic Separate 16 Amp RCBO’s AlertMaxx2 High Level Alarm (DMS-298) For internal wiring of the high level alarm, please refer to the AlertMaxx2 instruction manual. 13 Amp Non-switched fused spurs MaxxConnect Cable Finger Float Switch Primary Secondary From Mains From Mains Primary To Pump/...
  • Page 13: Wiring A Maxxconnect System

    MaxxConnect misconnections will destroy one or all connected units (this can be detected by the manufacturer) and void the guarantee. 18.0 Additional error codes The MaxxConnect introduces two new error codes to the Hi-PowerMaxx2 and one new error code to the AlertMaxx2/Rego1: Hi-PowerMaxx2 - flashing decimal point - Trying to find the AlertMaxx2/Rego1...
  • Page 14: Error Codes (Hi-Powermaxx2)

    20.0 Error codes Code Fault Inverter failure. Call support 0330 9000 999. Charger error. Call support 0330 9000 999. Overheated. The unit is exposed to temperatures above 35℃. Cannot detect an AlertMaxx2 or Rego1. Can be intermittent, will usually resolve. Depleted battery or disconnected.
  • Page 15: U-Menu

    22.0 Inverter check The inverter in the Hi-PowerMaxx2 will initiate a self-check after the initial config stage and then periodically. This is implemented in the software to ensure the inverter operates correctly and will provide power to the pump when needed.
  • Page 16 01992 523 523 info@deltamembranes.com www.deltamembranes.com Delta Membranes Ltd. Delta House, Merlin Way, North Weald, Epping, Essex. CM16 6HR...