HARTMANN ELECTRONIC PXIe Slimbox User Manual

6 slot 1u 19”

Advertisement

Quick Links

PXIe Slimbox Chassis
PXCe4006 6 Slot 1U 19"
User Manual
www.hartmann-electronic.com
Rev. 1.0
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the PXIe Slimbox and is the answer not in the manual?

Questions and answers

Summary of Contents for HARTMANN ELECTRONIC PXIe Slimbox

  • Page 1 PXIe Slimbox Chassis PXCe4006 6 Slot 1U 19” User Manual www.hartmann-electronic.com Rev. 1.0...
  • Page 2 + 49 711 8 66 11 91 E-Mail: info@hartmann-electronic.de Internet: www.hartmann-electronic.com Hartmann Electronic is a longstanding partner of the Embedded industry and has a variety of different backplanes. With our wide selection of backplanes and enclosure you can Build your perfect system platform Copyright © 2017 All rights and technical modifications reserved www.hartmann-electronic.com...
  • Page 3: Table Of Contents

    Contents 1. Safety ..................................4 Intended Application .............................. 4 Safety Symbols ..............................4 General Safety Precautions ..........................4 Safety Instructions ..............................5 Protection Against Electromagnetic Interference (EMI) ..................5 Electrostatic Discharge Precautions ........................5 Installation ................................5 Location ................................5 Voltage Hazards ..............................
  • Page 4: Safety

    1. Safety Intended Application PXI Express PXCe4006 series chassis are not end-products, so there is no valid approval for this unit. In Order to enable stand-alone functionality, additional elements are required. An operational system is achieved only by way of appropriate Measurement Cards. The completion and final testing of the units have been carried out, or at least supervised, by qualified technicians.
  • Page 5: Safety Instructions

    Safety Instructions The intended audience of this User's Manual is system Integrators and hardware/software engineers. The product has been designed to meet relevant standard industrial safety requirements. It must not be used except in its specific area of office telecommunication industry and industrial control. It shall not be used in safety-critical applications, life-sustaining appliances or in aircraft.
  • Page 6: Electrical Hazards

    Electrical Hazards The caution label on the system's rear near the grounding studs shows that you have to create an earth connection because there may be a high leakage current which is considered hazardous. High leakage current can cause injuries. Ensure that the system is properly grounded at all times, the following conditions shall be met: •...
  • Page 7: Product Description

    2. Product Description The PXCe4006 series Slimbox is a six Slot PXI Express Chassis. The Slimbox fully complies with the PXI-5 PXI Express Hardware Specification. To reduce space in modern test systems the PXCe4006 features a very compact 1U 19” design. There are one PXIe System Slot, one PXIe Peripheral Slot and four fully Hybrid peripheral slots available.
  • Page 8: Chassis Description

    Chassis Description Figure 2-1 Front view of the PXCe4006 series Slimbox 1 System slot Power LED 2 PXIe peripheral slot On/Standby momentary power switch 3 PXIe hybrid slots Removable fan tray 4 Fan LED www.hartmann-electronic.com Rev. 1.0...
  • Page 9: Fan Control

    Figure 2-2 Rear view of the PXCe4006 series Slimbox 1 10 MHz REF IN SMB PXI_TRIG[1] SMB 11 PXI_TRIG[6] SMB 2 10 MHz REF OUT SMB PXI_TRIG[2] SMB 12 PXI_TRIG[7] SMB 3 AC-Input PXI_TRIG[3] SMB 13 OFF/Standby Power Switch 4 Chassis Ground Screw PXI_TRIG[4] SMB 14 Dip Switch Auto Mode/Fan Control 5 PXI_TRIG[0] SMB...
  • Page 10 www.hartmann-electronic.com Rev. 1.0...
  • Page 11: System Controller Slot

    System Controller Slot The System Controller slot is Slot 1of the chassis and is a 4-Link configuration system slot as defined in CompactPCI Express and PXI Express Specification. The backplane connects the system slot using three times PCIe X4 to the peripheral slots. One PCIe link of the system slot connects to a PCIe Switch using PCIe Gen 2 X1.
  • Page 12: Pci Express Backplane Diagram

    PCI Express Backplane Diagram Figure 2-4 shows the PXCe4006 series backplane’s PCIe interface. Slot 3, 4 and 6 are connected with the system slot using PCIe X4. These slots have up to 2 GB/s (single direction) dedicated bandwidth (X4 Gen-2 PCI Express). Slots 2 and 5 are connected with the system slot using PCIe X1.
  • Page 13: Pxi Trigger Bus

    PXI Trigger Bus All slots share eight trigger lines. Figure 2-5 shows the PXCe4006 series backplane’s Trigger interface. System Reference Clock The PXCe4006 Slimbox chassis supplies PXI_CLK10, PXIE_CLK100, and PXIE_SYNC100 independently driven to each slot. PXI_CLK10, PXIe_CLK100 and PXIe_SYNC100 have the default timing relationship according to PXI-5 PXI Express Hardware Specification.
  • Page 14 The PLL is connected to the SMB 10 MHz input clock if the input clock is present. The presence of the input clock is automatically detected. If there is no input clock present, the clock source to the PLL is a 10 MHz Clock oscillator.
  • Page 15: Front Panel Leds

    Front Panel LEDs Figure 2-8 shows the location of the front panel LEDs. Table 2-1 describes the front panel LED states State Description Fan LED Chassis is powered off One or more chassis fans have failed Power LED Chassis is powered off Green Power supply is active, and all voltages are within normal operating ranges.
  • Page 16: Installation

    3. Installation Connecting Chassis Grounding The system contains gaskets at the chassis and board level to guard against electromagnetic interference (EMI). Each of the chassis’ individual components make contact with the gaskets and to the PE-stud inside the rear panel. The guide rails are also fitted with electrostatic discharge (ESD) contacts for each blade.
  • Page 17: Installing Hardware

    Installing Hardware 1.) Attach input power to the rear AC input using an appropriate AC power cable before installing the system controller. 2.) Install the PXIe Remote Controller into the system controller slot. Slot 1 is indicated with the red card guides.
  • Page 18: Installing Software

    Make sure that the installer is executed within the folder that is delivered with the installer. After running the installer the Hartmann Electronic PXCe4006 series slimbox is automatically detected through the National Instruments Measurement and Automation Explorer as shown in the Image below.
  • Page 19: Maintaining The Chassis

    4. Maintaining the Chassis Replacing the Fan Tray The fan tray can be accessed from the front on the right side of the chassis. Removing the Fan Tray • Loosen the four mounting screws (top and bottom) on the front of the fan tray. •...
  • Page 20: Service

    5. Service Technical support and Return for Service Assistance Please return the complete chassis system. For all product returns and support issues, please contact your Hartmann sales distributor or www.hartmann-electronic.com Please use the original packing material. Shipping without the original packing material might void the warranty.
  • Page 21: Specification

    6. Specification Electrical AC Input Operating Voltage Range 90 VAC to 264 VAC Operating frequency Range 47 Hz - 63 Hz Input Current 2 A (115 VAC) / 1 A (230 VAC) Efficiency >80% @ full load DC Output Short Circuit protection on all outputs. Over Power protection: 110% - 160% max of rated output Over Voltage protection on +5 V, +12 V, +3.3 V.
  • Page 22: System Synchronization Clocks

    System Synchronization Clocks PXI_CLK10 Maximum slot-to-slot skew: 250 ps Accuracy: ± 25 ppm Duty-factor: 45 % - 55 % PXIe_CLK100 Maximum slot-to-slot skew: 100ps Accuracy: ± 25 ppm Duty-factor: 45%-55% PXIe_SYNC100 Maximum slot-to-slot skew: 100 ps Accuracy: ± 25 ppm Duty-factor: 45 %-55 % External PXI_CLK10 output (SMB Rear panel connector)
  • Page 23: Mechanical

    Mechanical Slimbox weight: ca. 6 kg Figure 6-1 PXCe4006 series Slimbox Dimensions Front (Dimensions are in Millimeter). Figure 6-2 PXCe4006 series Slimbox Dimensions Side (Dimensions are in Millimeter). www.hartmann-electronic.com Rev. 1.0...
  • Page 24 Figure 6-3 PXCe4006 series Slimbox Dimensions Bottom (Dimensions are in Millimeter). www.hartmann-electronic.com Rev. 1.0...
  • Page 25: Cooling

    Cooling The PXI Express front I/O boards are cooled by forced air convection through 3 VDC axial fans (40 x 40x 28 mm, 11.3 CFM, 37 dB(A). Airflow Airflow from right to left. Caution! To ensure proper air flow within the system make sure that all slots are populated with either boards or filler panels.
  • Page 26: Pin Assignment

    7. Pin Assignment The Pin assignment applies with the PXI-5 PXI Express Hardware Specification and the CompactPCI PICMG 2.0 R. 3.0 specification. System Controller Slot (4 Link Configuration) PXI Express Hybrid Peripheral Slot PXI Express Peripheral Slot www.hartmann-electronic.com Rev. 1.0...
  • Page 27: System Controller Slot (4 Link Configuration)

    System Controller Slot (4 Link Configuration) +5Vaux SYSEN# WAKE# ALERT# PXI_TRIG3 PXI_TRIG4 PXI_TRIG5 PXI_TRIG6 PXI_TRIG2 PXI_CLK10 PXI_TRIG1 PXI_TRIG0 PXI_TRIG7 PXI_LBR6 PWR_OK PS_ON# LINKCAP PWRBTN# SMBDAT SMBCLK 4REFCLK+ 4REFCLK- 2REFCLK+ 2REFCLK- PERST# 3REFCLK+ 3REFCLK- 1REFCLK+ 1REFCLK- 1PETp0 1PETn0 1PERp0 1PERn0 1PETp1 1PETn1 1PETp2 1PETn2...
  • Page 28: Pxi Express Hybrid Peripheral Slot

    PXI Express Hybrid Peripheral Slot +5Vaux SYSEN# WAKE# ALERT# 3.3V 3.3V 3.3V PXI_TRIG3 PXI_TRIG4 PXI_TRIG5 PXI_TRIG6 PXI_TRIG2 ATNLED# PXI_CLK10 PXI_TRIG1 PXI_TRIG0 ATNSW# PXI_TRIG7 PXI_LBL6 PXI_LBR6 PXIe_CLK100+ PXIe_CLK100- PXIe_SYNC100+ PXIe_SYNC100- PRSNT# PWREN# SMBDAT SMBCLK MPWRGD PERST# 1REFCLK+ 1REFCLK- 1PETp0 1PETn0 1PERp0 1PERn0 1PETp1 1PETn1...
  • Page 29 REQ64# ENUM# 3.3V AD[1] V(I/O) AD[0] ACK64# 3.3V AD[4] AD[3] AD[2] AD[7] 3.3V AD[6] AD[5] 3.3V AD[9] AD[8] M66EN C/BE[0]# AD[12] V(I/O) AD[11] AD[10] 3.3V AD[15] AD[14] AD[13] SERR# 3.3V C/BE[1]# 3.3V IPMB_SCL IPMB_SDA PERR# DEVSEL# V(I/O) STOP# LOCK# 3.3V FRAME# IRDY# BD_SEL#...
  • Page 30: Pxie Peripheral Slot

    PXIe Peripheral Slot +5Vaux SYSEN# WAKE# ALERT# 3.3V 3.3V 3.3V PXI_TRIG3 PXI_TRIG4 PXI_TRIG5 PXI_TRIG6 PXI_TRIG2 ATNLED# PXI_CLK10 PXI_TRIG1 PXI_TRIG0 ATNSW# PXI_TRIG7 PXI_LBL6 PXI_LBR6 PXIe_CLK100+ PXIe_CLK100- PXIe_SYNC100+ PXIe_SYNC100- PRSNT# PWREN# SMBDAT SMBCLK MPWRGD PERST# 1REFCLK+ 1REFCLK- 1PETp0 1PETn0 1PERp0 1PERn0 1PETp1 1PETn1 1PETp2 1PETn2...
  • Page 31: Ordering Information

    8. Ordering Information Ordering Number Description PCI V(I/O) LMH0000792 PXI Express 6 Slot 1U Slimbox +5 V www.hartmann-electronic.com Rev. 1.0...

This manual is also suitable for:

Pxce4006

Table of Contents