Summary of Contents for LYSON W5014

  • Page 1 MANUAL Queen Bee Incubator Przedsiębiorstwo Pszczelarskie Tomasz Łysoń Spółka z o.o. Spółka Komandytowa 34-125 Sułkowice, ul. Racławicka 162, Polska www.lyson.com.pl, email: lyson@lyson.com.pl tel.33/875-99-40 , 33/870-64-02Siedziba Firmy Klecza Dolna 148 ,34-124 Klecza Górna...
  • Page 2 The following manual encompasses the devices bearing the following codes: W5014 Manual 1. The general safety principles for device operation 1.1. Operational principles 1.2. Electrical safety 1.3. Operational safety 2. Characteristics of the device 2.1. Device description 2.2. Controller handling 2.3.
  • Page 3: Device Characteristics

    1. GENERAL SAFETY PRINCIPLES FOR provided by safety supervising persons. Make sure DEVICE OPERATION that children do not play with the incubator 2. In case of any damage t the incubator, in order to Prior to device usage initiation, refer to the following avoid any danger the repair must be performed by a manual and act according the guidelines contained qualified person or a specialist service centre only.
  • Page 4 ŁYSOŃ IC-0x Description of the incubator: ..A- distilled water tank - 4L. B-water level indicator C-air holes D-controller E-incubator chamber F-transparent door to control the raising process G-incubator door Figure 2 ELEMENT DESCRIPTION After activation –...
  • Page 5 noticeable temperature over- regulating power regulations, the parameter shall be supply to the main heater. • lowered. based on the TH sensor Service screen readout, maintains calibration of T1 additional setpoint humidity sensor temperature readouts. The • based on the T1 sensor display shows temperature...
  • Page 6: Error Description

    2.4 Device technical parameters • damage to a solenoid valve that controls the -power supply 230V/5A filling -capacity 300 queen bee’s cells • stopping the liquid flow -external dimension: width. x depth. x height.- from tank 900x500x750mm. humidifier -shelf dimension: width. x depth. x height. – Defect signalling is accompanied 560x370x130mm.