158T9576.QXD
MODEL: T172CR
24 HR DIAL TIME SWITCH WITH "SKIPPER
AND SPRING-WOUND CARRY-OVER MOTOR
SINGLE POLE SINGLE THROW (SPST)
IN TYPE 3R RAINPROOF ENCLOSURE,
40 AMP. RESISTIVE, INDUCTIVE, TUNGSTEN OR
1000 VA. PILOT DUTY PER POLE - 120-277 VOLT AC;
2 HP (24 FLA) - 120V AC; 5 HP (28 FLA) - 240V AC.
CLOCK MOTOR: 208-277 VOLTS - 60 HZ.
CLOCK MOTOR VOLTAGE AND CYCLE MUST BE AS SPECIFIED. TO
ORDER REPLACEMENT, INDICATE ART NO. (WG--) ON MOTOR COVER.
TIME
POINTER
TIME
DIAL
OFF
TRIPPER
MANUAL
LEVER
WIRING INSTRUCTIONS: To wire switch follow diagram above. Use solid
or stranded COPPER only wire with insulation to suit installation. See
gauge selection table for normal service applications. To make power
connections remove 1/2 inch of insulation from wire ends. Insert bare
ends of wire under the pressure plate of terminals. Use 3/16 or larger
screwdriver to tighten terminal screws firmly. (25 lb-in minimum).
REPLACE INSULATOR BEFORE TURNING ON ELECTRICITY.
MIN.
MINIMUM
MAX.
LOAD
INSUL-
COPPER
ATION
WIRE SIZE
(AMP)
TEMP(°C)
(AWG)
14
15
60
12
60
20
10
60
30
8
40
75
PROGRAMMING INSTRUCTIONS
1. TO SET "ON" AND "OFF" TIMES: Hold trippers against edge of
CLOCK-DIAL, pointing to time (AM or PM) when ON and OFF
operations are desired, tighten tripper screws firmly. For additional
tripper pairs on CLOCK-DIAL order 156T1978A.
2. TO SET TIME-OF-DAY: Pull CLOCK-DIAL outward. Turn in either
direction and align the exact time-of-day on the CLOCK-DIAL (the
time now, when switch is being put into operation) to the pointer.
DO NOT MOVE POINTER.
3. TO SKIP OPERATION(S) ON SELECTED DAY(S): Insert SKIPPING
SCREW(S) in SKIPPER WHEEL for day(s) automatic operation(s)
is/are NOT required. Tighten screws firmly. Move MANUAL LEVER to
"OFF" and rotate SKIPPER WHEEL to locate correct day-of-week
opposite DAY ARROW--"YESTERDAY" if ON/CUTOUT TRIPPER
has not yet advanced wheel "TODAY" if it has.
OPERATING INSTRUCTIONS
• TO OPERATE SWITCH MANUALLY: Move MANUAL LEVER below
CLOCK-DIAL left or right as indicated by arrows. This will not effect
next operation.
CAUTION: TO AVOID SLOW SWITCH ACTION FAILURE, DO NOT OPERATE
SWITCH MANUALLY NOR PLACE A TRIPPER 4 HOURS PRIOR TO
ON/CUTOUT TRIPPER SWITCHING.
• IN CASE OF POWER FAILURE, reset
proper time-of-day. See programming instructions.
INTERMATIC INCORPORATED
SPRING GROVE, ILLINOIS 60081-9698
158T9576
7/27/04
3:40 PM
WIRING
ON/CUTOUT
DIAGRAM
TRIPPER
DAY
ARROW
SKIPPER
WHEEL
SKIPPING
SCREW
75°C INSULATION MAX. MOTOR
LOAD (HP)
3 PHASE
SINGLE PHASE
120 V.
240 V.
208 V.
240 V.
2
1/2
1
2 1/2
N/A
N/A
2
3
5
-
Page 1
®
GRD
A
1
277V
NEUT.
SUPPLY
LINE
FOR 208 OR 240V SUPPLY. CONNECT LINE 1
TO TERMINAL "A".
"
LISTED
885L
CLOCK
MOTOR
2
TO
LOAD
GROUND
PRESSURE PLATE
TERMINAL SCREW
MAKE SURE WIRE
INSULATION CLEARS
PRESSURE PLATE
CLOCK-DIAL to