Summary of Contents for Sanlien pALERT S303

  • Page 2 ................Sensor and Accessories ......................3 Delay Time Functions from Button ................... 5 The IP Showing ....................... 6 The Power Off ......................... 6 LCD Showing Description ....................7 Main Status Description ....................7 Booting Sequence ......................7 ..................... Installation Sequence ......................8 Mount Direction Description ....................
  • Page 3 WinSCP Retrieves Parameter File ................21 Earthquake Event Checking ..................23 PuTTY Operation (Engineer Use) ................... 24 PuTTY Login ......................... 24 PuTTY Login Window ....................24 Modify Sensor IP ......................25 Modify NTP ........................27...
  • Page 5 : : : : : : :...
  • Page 6 Sensor Quick Start Guide 1.2 Delay Time Functions from Button 1 Second IP Showing 2 Seconds NTP restart 3 Seconds Exercise cancel function 4 Seconds Hardware part reloading parameters 5 Seconds Firmware version showing 6 Seconds Reloading parameters without IP check (for saving time) 7 Seconds Firmware upgrading via internet 8 Seconds...
  • Page 9: Installation Sequence

    Sensor Quick Start Guide 2 Installation 2.1 Installation Sequence Anchor Hole Anchor Sleeve Step 1: Drilling a hole with sleeve anchor diameter and depth on the wall or platform(ground), diameter and depth around 0.5 and 1.58 inches. Step 2:Taps the sleeve in hole with hammer. Step 3:Drive the anchor into sleeve part and keep a sufficient distance (around 0.31 inch).
  • Page 10 Sensor Quick Start Guide Step 5: Tight these 3 hex screws on the wall or platform(ground). Level the bubble on the center (horizontal requirement). Hex screws Bubble on the center Step 6:GPS Antenna should be encapsulated with glue as below. #.
  • Page 11 (Default Mode)
  • Page 12 Change adaptor settings...
  • Page 13 Sensor Quick Start Guide Step 3: Right click and select properties. Ethernet properties Step 4: Click IP-V4 and set the same IP with sensor IP domain, for example, default sensor IP is 192.168.255.1, you can only change the 4 number with 192.168.255.xxx (the number below 254) in it.
  • Page 14 admin 1111...
  • Page 20 Sensor Quick Start Guide Click “SOH Information”, status of health shows the basic health condition, the items see below. If GNSS connected stable, the GNSS shows “sync.”, LCD always appears a heart -beat cycling dot on the right top of location between the number of firmware version. Notice: If sensor repeat showing “no heartbeat”...
  • Page 23 Sensor Quick Start Guide Default “[SAMPLING_RATE]” is “100” in sampling per second, it optional provides “200”, ”500” and “1000”. Default output format is miniseed, it can be changed to CSV format by adding the hashtag symbol (“#”) in front of 2 command lines from “[EVENT_FILE_FORMAT]” command. “[RECORD_INTENSITY]”...
  • Page 27 。...
  • Page 29 Sensor Quick Start Guide Hashtag server x.x.x.x iburst Add 2 lines of commands: “server 127.127.1.0” “fudge 127.127.1.0 stratum 10” ********** PuTTY Official Webpage to download: https://www.chiark.greenend.org.uk/~sgtatham/putty/latest.html...
  • Page 31  ...
  • Page 32 Sensor Quick Start Guide Modbus Registeration Mapping-pALERT S303 AO (4xxxx) Modbus AO Address (4XXXX) Register R/W Label Description Bit 0: NTP SYNC. Bit 1: server0 connection Bit 2: server1 connection Bit 3: server2 connection 0x0063 R SYNC_FLAG Bit 8: admin. server0 connection Bit 9: admin.
  • Page 33 Blank 0x007F R STALTA_VALUE STA/LTA value. The unit is 0.01 second. Palert S303 will calculating the maximum acceleration value in every axis, this is the resgisteration to register A 0x0080 R EVENT_A_MAX axis in count during earthquake occured. 1 gal = 16.718 counts.
  • Page 34 C axis in count during earthquake occured. 1 gal = 16.718 counts. 0x0086 Blank 0x0087 Blank Palert S303 starts to calculate Pd value after detecting P 0x0088 R PD wave. The unit is 0.001 cm. Palert S303 starts to calculate tau-c value after detecting P 0x0089 R TOUC wave.
  • Page 35 Sensor Quick Start Guide Modbus AO Address (4XXXX) Register R/W Label Description 0x0097 R SYSTEM_SECOND The status of system in second. 0x0098 ~ Blank 0x009D A axis real time displacement in cm. The unit is 0.001cm 0x009E R A_DISPLACEMENT (Functioning in Pd triggering was enabled ). 0x009F Blank PGA WARNING value (The sedond threshold).
  • Page 36 Sensor Quick Start Guide Modbus AO Address (4XXXX) Register R/W Label Description B axis calibrate factor in 1 G (Unit: 1 G). This value has filled 0x00A8 R MEMS_CAL_B_AXIS before sold out in factory. C axis calibrate factor in 1 G (Unit: 1 G). This value has filled 0x00A9 R MEMS_CAL_C_AXIS before sold out in factory.
  • Page 37 Sensor Quick Start Guide Modbus AO Address (4XXXX) Register R/W Label Description 0x00C3 R VECTOR_GAL_NOW Real time vector acceleration. The unit is 0.1 gal. 0x00C4 Blank 0x00C5 Blank 0x00C6 R VERSION The software version. 0x00C7 R SERIAL_NO Serial number 0x00C8 ~ Blank 0x00CA 0x00CB...
  • Page 38 Sensor Quick Start Guide Modbus AO Address (4XXXX) Register R/W Label Description 0x00E8 R SA03_A_MAX The maximum of A axis SA value (3 Hz), CEB mode only. 0x00E9 R SA03_B_MAX The maximum of B axis SA value (3 Hz), CEB mode only. 0x00EA R SA03_C_MAX The maximum of C axis SA value (3 Hz), CEB mode only.
  • Page 39 Sensor Quick Start Guide Modbus AO Address (4XXXX) Register R/W Label Description 0x0109 Blank 0x010A R ERR_CNT The number of error counting VECTOR_GAL_EVENT_S The vector acceleration calculated in every second during 0x010B ECOND earthquake event. The unit is 0.1 gal. A_COUNT_EVENT_SEC The maximum vector acceleration of A axis calculated in 0x010C...
  • Page 40 Sensor Quick Start Guide Modbus AO Address (4XXXX) Register R/W Label Description The maximum vector velocity of B axis calculated in every 0x011E VELOCITY_B_FLOAT_SE second during earthquake event. The data is floating point 0x011F COND format. The unit is mm/sec. The maximum vector velocity of C axis calculated in every 0x0120 VELOCITY_C_FLOAT_SE...
  • Page 41 Modbus AI Address (3XXXX) Read only Register Label Description 0x00A8 DORTS_RELAY_REG DORTS DO output status. 0x00A9 ISO2631_RELAY_REG ISO2631 DO output status. 11: pALERT S303 Taiwan mode 0x00B3 INSTRUMENT_CODE 12: pALERT S303 China mode 14: Palert220 0x00C7 MBUS_LCD_MAP_ADDR LCD marquee words output. ~ 0x00DB 0x018F GPS_LOCK GPS locked information.
  • Page 42 Sensor Quick Start Guide Modbus AI Address (3XXXX) Read only Register Label Description 0x019C NTP_POLL Time synchronization frequency. The unit is second. NTP testing value, 337 means time synchronization 0x019D NTP_REACH stabilized. NTP time delay value. The value to count the back-and- 0x019E NTP_DELAY forth time.
  • Page 43 Sensor Quick Start Guide Modbus AI Address (3XXXX) Read only Register Label Description 0x0348 DORTS_2HZ_DB DORTS dB value in 2 Hz. The unit is 0.01 dB. 0x0349 DORTS_4HZ_DB DORTS dB value in 4 Hz. The unit is 0.01 dB. 0x034A DORTS_8HZ_DB DORTS dB value in 8 Hz.