MOUNTING & WIRING (continued)
6.
Select appropriate fixture wire to match incoming voltage.
Models FL250HPS, FL400HPS, FL250MH & FL400MH
are shipped with 277 V wire ready for connection. Models
FL250HSPT, FL400HPST, FL250MHT & FL400MHT are
shipped with 347 V wire ready for connection. If supply voltage
is lower, cap wire marked 277V (or 347 V for tri-tap models)
with appropriate twist on wire connector and strip fixture wire
marked with matching voltage (see Figure 3 through Figure 5)
7.
Using provided twist on or other approved connectors,
connect the fixture wires to the 3-wire cord.
a.
Connect the selected voltage fixture wire to the Black
(hot) cord wire.
b.
Connect the white fixture wire marked "COM" to the
White (neutral) cord wire.
c.
Connect the Green (equipment ground) cord wire to
the fixture ground screw.
8.
Confirm all unused fixture wires are capped.
9.
Replace and secure reflector/lampholder assembly with
(4) screws.
10.
Install the fixture to the Trunion Mounting Bracket using the
(2) Trunion Bolts. On the trunion assembly there are (3)
position holes in the outer yoke and (5) positioning hoes in
the inner yoke. Align the positioning holes as desired and
secure with Positioning Screw.
11.
Using approved twist on wire connector, connect the free
end of the 4ft cord to the supply wires inside an approved
outdoor,watertight junction box.
a.
Connect the Black (hot) cord wire to the Black (hot)
supply wire.
b.
Connect the White (neutral) cord wire to the White
(neutral) supply wire.
277 V
240 V
208 V
120 V
CAP
COM
COM
347 V
277 V
X3
120 V
CAP
COM
COM
If within one (1) year from the date of purchase, this product fails due to a defect in material or workmanship, Intermatic Incorporated will repair or replace it, at its sole option,
free of charge. This warranty is extended to the original purchaser only and is not transferable. This warranty does not apply to: (a) damage to units caused by accident,
dropping or abuse in handling, acts of God or any negligent use; (b) units which have been subject to unauthorized repair, opened, taken apart or otherwise modified;
(c) units not used in accordance with instructions; (d) damages exceeding the cost of the product; (e) sealed lamps and/or lamp bulbs; (f) the finish on any portion of the
product, such as surface and/or weathering, as this is considered normal wear and tear; (g) transit damage, initial installation costs, removal costs, or reinstallation costs.
INTERMATIC INCORPORATED WILL NOT BE LIABLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES. SOME STATES DO NOT ALLOW THE EXCLUSION
OR LIMITATION OF INCIDENTAL OR CONSEQUENTIAL DAMAGES, SO THE ABOVE LIMITATION OR EXCLUSION MAY NOT APPLY TO YOU. THIS WARRANTY
IS IN LIEU OF ALL OTHER EXPRESS OR IMPLIED WARRANTIES. ALL IMPLIED WARRANTIES, INCLUDING THE WARRANTY OF MERCHANTABILITY AND THE
WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE, ARE HEREBY MODIFIED TO EXIST ONLY AS CONTAINED IN THIS LIMITED WARRANTY, AND SHALL
BE OF THE SAME DURATION AS THE WARRANTY PERIOD STATED ABOVE. SOME STATES DO NOT ALLOW LIMITATIONS ON THE DURATION OF AN IMPLIED
WARRANTY, SO THE ABOVE LIMITATION MAY NOT APPLY TO YOU.
This warranty service is available by either (a) returning the product to the dealer from whom the unit was purchased, or (b) mailing the product, along with proof of pur-
chase, postage prepaid to the authorized service center listed below. This warranty is made by: Intermatic Incorporated/After Sales Service/7777 Winn Rd., Spring Grove,
Illinois 60081-9698/815-675-7000 http://www.intermatic.com Please be sure to wrap the product securely to avoid shipping damage.
THESE INSTRUCTIONS DO NOT COVER ALL VARIATIONS IN EQUIPMENT, NOR DO THEY PROVIDE FOR ALL SITUATIONS
RELATED TO FIXTURE INSTALLATION, OPERATION OR MAINTENANCE. FOR FURTHER INFORMATION CONTACT YOUR
DISTRIBUTOR OR INTERMATIC INCORPORATED - SPRING GROVE, ILLINOIS 60081 (815) 675-7000 www.intermatic.com
X3
X1
High Pressure
LAMP
Sodium 250 &
IGN-02
400 Watt
Figure 3
X2
High Pressure
X1
Sodium 250 &
LAMP
IGN-02
400 Watt w/tri-tap
Figure 4
X2
LIMITED 1 YEAR WARRANTY
c.
Connect the Green (equipment ground) cord wire to the
Green (equipment ground) supply wire.
Alternate wiring: If desired connections may be made inside
fixture using supply wire rating minimum 125°.
12.
Screw lamp into lampholder until finger-tight.
13.
Install, close, and secure lens cover with (2) screws. To
weatherproof fixture, seal all holes in housing (mounting
conduit, plugs, photocontrols, etc.) with silicone sealant.
14.
To operate, restore power to the circuit and switch light on.
CAUTION
(Metal Halide Lamps Only)
Do not use lamp beyond manufactures rated life to reduce
chance of lamp rupture.Turn lamp off at least once for 15
minutes per week to reduce chance of lamp rupture.
LAMP REPLACEMENT
CAUTION
Use lamp of correct type and wattage as specified on fixture.
1.
Turn off power at circuit breaker or fuse box. Allow fixture and
lamp to cool.
2.
Loosen (2) screws and swing hinged fixture lens door open.
Remove old lamp and replace with new lamp of correct type
and wattage. Screw lamp into socket in lampholder until
finger-tight.
3.
Close and secure lens door, making sure that gasket is
properly seated, free of debris, and compressed to seal out
moisture.
4.
Turn power back on.
5.
Properly dispose of lamp per manufacturer's recommendations.
277 V
240 V
208 V
120 V
COM
347 V
277 V
120 V
COM
Metal Halide
LAMP
250 & 400 Watt
Figure 4
COM
Metal Halide
250 & 400 Watt
LAMP
w/tri-tap
Figure5
COM
158--00108

Advertisement

loading

This manual is also suitable for:

Fl250hsptFl250mhFl250mhtFl400hpsFl400hpstFl400mh ... Show all