Electronic Specification; Environmental & Housing Specification; Optical Chart; Installation - Wahl HEAT SPY R10 User Manual

Compact fixed infrared sensor
Table of Contents

Advertisement

4.2. Electronic Specification

Analog
Cable
Power Supply
4.3. Environmental & Housing Specification
Ambient
w/ Air Cooling
w/ Water Cooling
Storage
Relative Humidity
Protection Class
Shock
Vibration
Housing Material
Dimensions
Weight

5. Optical Chart

The R10 optical field of view is nominally 20:1 D:S ratio. D:S ratio is an abbreviation for Distance to Spot
ratio. For the R10, for every 20 units of measure distance, the target diameter that the R10 is measuring
will be 1 unit. For example at a distance of 20 inches the unit will be measuring a 1" diameter target and
at 60 inches it will be measuring a 3" diameter target. The minimum diameter is approximately .35
inches (8.9mm).
Distance mm
Target mm
Distance in
Target in

6. Installation

0
200
8.9
10
0
8
0.35
0.4
4 – 20 mA
2 cond. shielded, PVC, R10A = 5 feet, R10A10 = 10 feet
24 VDC
0° – 70°C (32° – 158°F)
0° – 90°C (32° – 194°F)
0° – 200°C (32° – 392°F)
-20° – 70°C (-4° – 158°F)
10% - 95% non-condensing
IP65 (NEMA 4)
MIL-STD-810D
MIL-STD-810D
304 Stainless Steel
18 x 120 mm (0.7 x 4.75 in) / Thread: M18 x 1
270g (9.52 oz)
400
600
20
30
16
24
0.8
1.2
800
1000
40
50
32
40
1.6
2.0
4

Advertisement

Table of Contents
loading

This manual is also suitable for:

R10aR10a10R10jR10j10R10kR10k10l r10v ... Show all

Table of Contents