FCS PDS II
Product Manual

Advertisement

Table of Contents
loading

Summary of Contents for Flow Controller Systems FCS PDS II

  • Page 1 FCS PDS II Product Manual...
  • Page 2 Important information:  Please read the instructions before operating the product. : Warning Tubing may crack due to wear. This results in the overflow of  fluid from tubing. People and instruments may be injured. You must check tubing often and change tubing as needed. Please connect power directly to a wall socket.
  • Page 3: Table Of Contents

    Catalog PDS II Product Introduction .............. - 1 - PDS II Appearance ................- 2 - PDS II Controller Interface fracture........... - 4 - Filling Volume Reference Parameter (Media is Water) ....- 14 - PDS II Technical Specifications ............- 15 - Product Size Chart:...
  • Page 4: Pds Ii Product Introduction

    PDS II PDS II Product Introduction II(Programmable Dispensing System)Series includes controller many independent filling units. Each filling unit has two working modes: Independent working mode and logic working mode. In independent working mode, each filling unit can be used as one independent peristaltic pump to achieve the transferring or dispensing of liquid.
  • Page 5: Pds Ii Appearance

    PDS II PDS II Appearance Composition: A——Pump Heads B——Filling Unit C——Controller Product Composition PDSII consists of one controller and many independent filling units, adding or deleting filling units as needed. You can also set the validity of each filling unit as needed. Below is a diagram of cascading many filling units: ①...
  • Page 6 PDS II Cascading instruction: 1 - All the filling units (independently) can connect to the controller. The controller has a separate interface for each filling unit. 2 - Each controller can control 8 filling units max. Back side of filling unit Interface Specification:A——Power switch B——Power socket C——Interface connecting the controller(G)...
  • Page 7 PDS II PDS II Controller Interface Hierarchy 系统 Main Interface 主界面 Unit 选择要查 单元 有效 常用 全速 外控设置 External 时间 Interface at Effective Common Review See the Date and parameter 步骤查看 control full speed 界面 看的单元 参数设置 单元 模式 界面 日期...
  • Page 8 PDS II effective units every 5 seconds. B - Dynamic display:Display the working state of each unit in real time, dynamically display the monitoring result. It also has an alarm function. If a bottle appears red (alarm signal), the responding unit‟s bottle is absent. Please check the production line.
  • Page 9 PDS II Common mode settings: Click this button to enter the common mode interface. Effective unit: Click this button to enter the effective unit selection interface. External control setting interface: Click this button to enter the communication setup interface. - Loop unit selecting interface Please choose to view the unit Select the unit In the main interface, you can click the “FCS”...
  • Page 10 PDS II 5 - Effective unit interface. The effective unit interface diagram is below: Click the “effective unit” button in the main interface to enter the effective unit selection interface. You can set the validity of the unit here. When finished, you can click the “OK”...
  • Page 11 PDS II When the unit stops working, click the bottle which selects it as the independent effective unit to enter the parameter settings interface of the corresponding unit. A - Unit number display:This area displays the current parameter settings' unit number. B - System parameter settings:This area is for setting the system parameters of this unit.
  • Page 12 PDS II Test Vol Fine adjust unit7 0.0000 +0.0000 uL Step 03 start Volume 7.0000 Rum time Reset 60.00 In the independent operation parameter settings interface, click the calibration button to enter the calibration interface. In dispensing mode, first click the “dispensing groups” drop-down list, then choose the dispensing groups for calibrating unit (to ensure the filling accuracy, you need to calibrate separately for each group), target volume, and working time are data set before...
  • Page 13 PDS II displays the average volume. Click „Calibration‟ button. Display calibration successful. D - Test again to check whether the dispensing volume meets requirements. If higher accuracy is needed, you can use the adjust function. Click the „Add‟ or „Dec‟ button to micro-adjust the dispensing volume to meet high accuracy dispensing.
  • Page 14 PDS II Please select the vaild unit and itd direction √ Unit1 √ Unit2 Unit3 Unit4 Unit5 Unit6 Unit7 √ Unit8 √ Back Click on the full speed button in the main interface takes you to the full speed interface. After selecting the direction and number of the unit, click the full speed button.
  • Page 15 PDS II Click the common mode button in the main interface to enter Call button: Click this button to call the common mode. The  operating parameters of the corresponding unit after the call will be changed to the parameters of the commonly used mode. Delete button: Select a common mode.
  • Page 16 PDS II Lack on/off Set baud rate 9600 RS232/RS485 RS232 Stave NO. COM ON/OFF Return Click the external control set button in the main interface to enter the external control set interface. The interface can set the relevant parameters of communication and the start/stop of the stop filling due to lack of bottle.
  • Page 17: Filling Volume Reference Parameter (Media Is Water)

    PDS II minus button in order to select the unit that you wish to operate. "ALL" is the operation for all independent operation of the effective unit. 13 - Set date time interface Set date and time interface: 12-hour 2012-3-15 24-hour 8:45:35 AM Set Date...
  • Page 18: Pds Ii Technical Specifications

    PDS II 25#/15 25#/15 25#/15 17#/24 17#/24 DZ25-3L PDS II Technical Specifications Dispensing volume 0.1-9999ml Prime speed 600rpm Dispensing time range 0.1-9999s External control Switch signal Speed resolution Pause time range 0.5-9999s 0.1rpm - 15 -...
  • Page 19: Product Size Chart

    PDS II Volume resolution 0.01ml Temperature 0-40℃ Time resolution 0.01s Relative Wet <80% 1-9999,0means Controller Dimension 240*185*85 Dispensing numbers unlimited (L*W*H) Speed range 0.1-600rpm Controller weight 2.5Kg Back suction angle 0-360° IP rate IP31 Product size chart: Filling unit size chart: Unit (mm) - 16 -...
  • Page 20: Main Functions And Features Of Pds Ii

    PDS II Main functions and features of PDS II  All models of pump heads can be installed on the PDS pump. The same controller can control a variety of different models of pump head at the same time.  Precise angle control technology to achieve high precision filling ...
  • Page 21: External Control Interface Instruction Of The Control Unit

    PDS II pump stops working. External control start/stop function: Each channel can  independently receive external control signals, but also can start/ stop all the effective channels at the same time. The pump can be controlled by the host computer when working in filling line. ...
  • Page 22: Maintenance

    PDS II (signal rising edge effective, high level duration is 200ms) DIRn:The filling unit commutation signal line (signal rising edge effective, high level duration is 200ms) ② Bottle absent stop signal: Active switch signal input (5VDC), Recognize the signal as high level effective COM: External control signal input ③...
  • Page 23: Warranty And After Sales Service

    Warranty and After Sales Service: We support 1 year of warranty (does not include tubing).  Warranty does not cover the improper operation of this equipment. Flow Controller Systems 2950 Buskirk Ave Suite 300 Walnut Creek CA 94597 Tel: 925-516-4459 Website: flowcontrollersystems.com Email: justin@fcs-us.net...