Advertisement

Quick Links

ChickenMaster PRO User Guide
Firmware 01.14B
ALARM LED will flash when an alarm
threshold is triggered
AUTO MODE Button Enables or
Disables all Automatic Mode Functions
Allows UP, DOWN, LEFT & RIGHT
movement through the Menus &
Status Screens
Description of Push Buttons and their Functions:
Pressing any button will turn ON the LCD Backlight, it will turn OFF after 60 Seconds of inactivity.
If the User is in any of the MENU/STATUS Screens with longer than 60 Seconds of inactivity the
display will return to the MAIN Home Screen.
From the MAIN HOME screen, pressing the MENU/OK button once will enter the SETTINGS MENU.
Every time the ESCAPE button is pressed, returns the user back up one level in the MENU Structure
and will abort any changes made if the user was entering data.
Pressing the MENU/OK button will accept any data entered, and then move back to the previous
screen.
UP button increments a step UP every time it is pressed;
holding down for 2 Seconds initiates the fast scroll feature.
DOWN button increments a step DOWN every time it is pressed;
holding down for 2 Seconds initiates the fast scroll feature.
RIGHT button increments to the RIGHT every time it is pressed.
LEFT button increments to the LEFT every time it is pressed.
AUTO MODE button toggles between AUTO ON and AUTO OFF Mode.
(AUTO ON Mode is the default on every boot up regardless of what mode the
ChickenMaster PRO was in prior to boot up).
AUTO ON LED stays lit in AUTO ON Mode.
AUTO OFF LED pulses ON & OFF once every second in AUTO OFF Mode.
RED ALARM LED pulses ON & OFF twice every second when an alarm is triggered.
Initial Boot Up Procedure:
On initial out of the box power up the User will be prompted to enter the following values before the
ChickenMaster PRO can be used.
Date, Daylight Saving Time (DST), Local Time, UTC Time Zone, Latitude & Longitude
Once the above data has been entered the Main Home Screen will be displayed.
Please refer to the ChickenMaster PRO Quick-Start Guide on Page 43.
If the ChickenMaster PRO has been powered down for longer than 120 Hours causing the Internal
Battery to run flat then the Initial Boot up Procedure will initiate again on power up.
Other than the first boot up requirements all previously entered USER settings will remain unchanged and
will NOT be erased.
The ERASE ALL SETTINGS & DO FACTORY RESET (Page 23) also initiates the
Initial Boot Up Procedure and Installs all the Factory Default Values. (See Default Value Tables on pages 39,
40 & 41)
ALL USER settings will be deleted when this option is selected.
The
www.farmtronics.com.au
(or after an ERASE ALL SETTINGS & DO FACTORY RESET)
, 100 Fox Drive, Dandenong South. Victoria. 3175.
Den
Revision 1.0 23/05/2022
4 Line, 20 Character per line LCD
Enters MENU MODE & Accepts any
changes that have been made
ABORTS changes made & goes back UP
one level in the MENU structure each
Phone: 0411 479 411
Page 1 of 43
Display with Backlight
time it is pressed

Advertisement

Table of Contents
loading

Summary of Contents for FarmTronics ChickenMaster PRO

  • Page 1 Please refer to the ChickenMaster PRO Quick-Start Guide on Page 43. If the ChickenMaster PRO has been powered down for longer than 120 Hours causing the Internal Battery to run flat then the Initial Boot up Procedure will initiate again on power up.
  • Page 2 Automatic Mode has been DISABLED via the Settings Menu or the AUTO Mode is in AUTO Mode OFF External Doors have had MANUAL Intervention or the ChickenMaster PRO has just been powered up so their position is UNKNOWN. The External Doors will be Automatically OPENING at the time displayed External Doors have had MANUAL Intervention or the ChickenMaster PRO has just been powered up so their position is UNKNOWN.
  • Page 3 Automatic Mode has been DISABLED via the Settings Menu or the AUTO Mode is in AUTO Mode OFF NEST BOX GATES have had MANUAL Intervention or the ChickenMaster PRO has just been powered up so their position is unknown. They will be Automatically OPENING at the time displayed NEST BOX GATES have had MANUAL Intervention or the ChickenMaster PRO has just been powered up so their position is unknown.
  • Page 4 Required DAYLIGHT LENGTH is OK and there is no requirement for the use of any artificial lighting INTERNAL LIGHTING is currently ON and the ChickenMaster PRO has been switched to the AUTO OFF Mode or Automatic Mode for the INTERNAL LIGHTING is DISABLED via Settings. I.e. MANUAL Control was used INTERNAL LIGHTING is currently OFF and the ChickenMaster PRO has been switched to the AUTO OFF Mode or Automatic Mode for the INTERNAL LIGHTING is DISABLED via Settings.
  • Page 5 Page 5 of 43 ChickenMaster PRO User Guide Firmware 01.14B Revision 1.0 23/05/2022 Status Screen 9 of 15 – WIND SENSOR FOUR Individual status screens are available. Feature has been DISABLED via the Settings Menu Automatic Mode has been DISABLED via the Settings Menu or the AUTO Mode is in AUTO Mode OFF WIND SAFE Mode has been triggered due to a high wind event.
  • Page 6 Displays the total amount of POWER OUTAGES that have occurred since initial power up or after the Power Loss Counter was reset to zero via the SETTINGS Menu. Status Screen 15 of 15 – FIRMWARE VERSION Displays the current FIRMWARE VERSION of your ChickenMaster PRO End Status Screens , 100 Fox Drive, Dandenong South. Victoria. 3175.
  • Page 7: Main Settings Menu

    Pressing and HOLDING the DOWN arrow button will CLOSE the EXTERNAL DOORS. MANUAL CONTROL of the External Doors can be used even if the ChickenMaster PRO is in the AUTO OFF position or if the External Doors AUTOMATIC MODE has been DISABLED in settings.
  • Page 8: Internal Lighting

    Pressing and HOLDING the DOWN arrow button will CLOSE the NEST BOX GATES. MANUAL CONTROL of the Nest Box Gates can be used even if the ChickenMaster PRO is in the AUTO OFF position or if the Nest Box Gates AUTOMATIC MODE has been DISABLED in settings.
  • Page 9: Courtesy Lighting

    The Courtesy Lights are on a Countdown timer so they cannot be left ON inadvertently. MANUAL COURTESY LIGHTING Control can also be used even if the ChickenMaster PRO is in the AUTO OFF position or even if the COURTESY LIGHTING AUTOMATIC MODE has been DISABLED in settings.
  • Page 10: System Settings

    Sets the Countdown Timer Interval for the courtesy lights Returns the Power Loss Counter to ZERO Runs a TEST hardware procedure testing all the ChickenMaster PRO Inputs and Outputs Restores the system default settings, Refer to Tables on pages 39, 40 & 41 Erases ALL user settings and initiates a Full Factory Reset.
  • Page 11: Set Latitude

    Page 11 of 43 ChickenMaster PRO User Guide Firmware 01.14B Revision 1.0 23/05/2022 Main Settings Menu System Settings SET DATE Using the Arrow buttons you can move the cursor left or right and then up or down to scroll the dates.
  • Page 12 Page 12 of 43 ChickenMaster PRO User Guide Firmware 01.14B Revision 1.0 23/05/2022 Main Settings Menu System Settings SET LONGITUDE User selects their local LONGITUDE in Degrees by using the UP or DOWN arrow buttons. A fast scroll will occur by holding down the UP or DOWN Buttons for longer than 2 seconds.
  • Page 13 The Automated Doors can close unexpectedly when a wind sensor is connected and ENABLED. If you are intending to work inside the caravan behind an Automated Door, you must switch the ChickenMaster PRO to AUTO OFF Mode. (Remember to switch it back to AUTO ON Mode when you have finished your tasks)
  • Page 14: Installer Options

    Page 14 of 43 ChickenMaster PRO User Guide Firmware 01.14B Revision 1.0 23/05/2022 If the EXTERNAL DOORS have had MANUAL Intervention via the MANUAL Control menu then this places the Doors in an UNKNOWN POSITION. If a wind event occurs while in an UNKNOWN POSITION, so that the Controller can determine a known position it will close the Doors for the EXTERNAL DOORS RUNTIME INTERVAL (Automatic Door Menu) and then assume the DOOR OPEN RUNTIME SAFE INTERVAL position.
  • Page 15 Page 15 of 43 ChickenMaster PRO User Guide Firmware 01.14B Revision 1.0 23/05/2022 Sets the Wind Speed countdown timer in MINUTES and will initiate when the Wind Speed Lockout Value is reached Sets the amount of time in SECONDS that the DOOR will travel when opening to a Wind SAFE Mode Position...
  • Page 16: Alarm Settings

    Page 16 of 43 ChickenMaster PRO User Guide Firmware 01.14B Revision 1.0 23/05/2022 Main Settings Menu System Settings Wind Sensor Installer Options DOOR CLOSE RUNTIME SAFE INTERVAL Default value = 015 SECONDS Main Settings Menu System Settings ALARM SETTINGS Settings for the External Alarm Input functionality and features...
  • Page 17: Low Battery Alarm

    Page 17 of 43 ChickenMaster PRO User Guide Firmware 01.14B Revision 1.0 23/05/2022 Main Settings Menu System Settings Alarm Settings EXTERNAL ALARM INPUT INPUT AVAILABILITY Default value = DISABLED Main Settings Menu System Settings Alarm Settings EXTERNAL ALARM INPUT INPUT MODALITY...
  • Page 18 Page 18 of 43 ChickenMaster PRO User Guide Firmware 01.14B Revision 1.0 23/05/2022 Main Settings Menu System Settings Alarm Settings LOW BATTERY ALARM THRESHOLD VALUE Default value = 11.5 VOLTS Main Settings Menu System Settings Alarm Settings STROBE TRIGGERS Enables/Disables the Strobe from flashing when a Voltage Lockout for the External Doors has occurred...
  • Page 19 Page 19 of 43 ChickenMaster PRO User Guide Firmware 01.14B Revision 1.0 23/05/2022 Main Settings Menu System Settings Alarm Settings Strobe Triggers VOLTAGE FAILSAFE NEST BOX GATES Default value = ENABLED Main Settings Menu System Settings Alarm Settings Strobe Triggers...
  • Page 20: Low Battery Voltage Alarm

    Page 20 of 43 ChickenMaster PRO User Guide Firmware 01.14B Revision 1.0 23/05/2022 Main Settings Menu System Settings Alarm Settings Strobe Triggers EXTERNAL ALARM INPUT TRIGGERED Default value = DISABLED Main Settings Menu System Settings Alarm Settings Strobe Triggers LOW BATTERY VOLTAGE ALARM...
  • Page 21 Page 21 of 43 ChickenMaster PRO User Guide Firmware 01.14B Revision 1.0 23/05/2022 Main Settings Menu System Settings Courtesy Lights COURTESY LIGHTS AVAILABILITY Default value = ENABLED Main Settings Menu System Settings Courtesy Lights COUNTDOWN TIMER INTERVAL Default value = 030 MINUTES...
  • Page 22: Test Hardware

    The Test Hardware menu will initiate eight individual TEST cycles as pictured above. When using this feature the ChickenMaster PRO will ignore items such as Voltage Lockouts and Enable any Disabled items so that the TEST HARDWARE process can proceed.
  • Page 23: Restore Factory Defaults

    Page 23 of 43 ChickenMaster PRO User Guide Firmware 01.14B Revision 1.0 23/05/2022 Main Settings Menu System Settings Restore Defaults RESTORE FACTORY DEFAULTS Default value = NO This option will restore all factory defaults except the following: (Refer to Tables on pages 39, 40 & 41) LOCAL TIME, DATE, UTC Time Zone, LATITUDE &...
  • Page 24 SUNRISE/SUNSET setting, the user can configure to use either Modality. TIME CLOCK settings occur at fixed User entered times to OPEN or CLOSE the External Doors. SUNRISE/SUNSET settings occur at variable times that the ChickenMaster PRO mathematically calculates based on the Latitude and Longitude of the user’s geographic location.
  • Page 25: Door Open Time

    Page 25 of 43 ChickenMaster PRO User Guide Firmware 01.14B Revision 1.0 23/05/2022 OPEN/CLOSE SETTINGS (When the TIME CLOCK Option is selected) Main Settings Menu External Doors Automatic Mode Open Close Settings TIME CLOCK OPEN/CLOSE SETTINGS Main Settings Menu External Doors...
  • Page 26 Door Open, Sunrise Offset Functionality: Example: If the ChickenMaster PRO has calculated the Sunrise time to open the doors to be 06:30 and the user has set a SUNRISE OFFSET to (Minus) – 30 Minutes then the EXTERNAL DOORS will open at 06:00 (30 minutes before sunrise) If the Offset value were set to 000 (Zero) then the Doors would open exactly at Sunrise (NO Offset).
  • Page 27: Installer Options

    VIA LIGHTING DLR, Functionality: Example: If the ChickenMaster PRO calculated the DAYLIGHT LENGTH REQUIREMENT (DLR) value for the Morning Internal Lighting to turn ON at 04:15 and the Open Doors OFFSET is set to (Minus) - 30 Minutes then the EXTERNAL DOORS would open at 03:45.
  • Page 28 Most actuators have a travel stroke time from fully open to fully closed of approximately 45-50 seconds. Because the actuators are only two wire and do not have a position feedback, the ChickenMaster Pro cannot determine the actuators actual position.
  • Page 29 Page 29 of 43 ChickenMaster PRO User Guide Firmware 01.14B Revision 1.0 23/05/2022 Main Settings Menu External Doors Installer Options VOLTAGE LOCKOUT AVAILABILITY Default value = ENABLED Main Settings Menu External Doors Installer Options Voltage Lockout Availability VOLTAGE LOCKOUT VALUE Default value = 11.0 Volts.
  • Page 30 Page 30 of 43 ChickenMaster PRO User Guide Firmware 01.14B Revision 1.0 23/05/2022 Main Settings Menu NEST BOX GATES Enables/Disables this feature from working in Automatic Mode Used to set the Nest Box Gates Open and Close settings Password Protected area! Installer options are factory set, making changes to these settings without fully understanding their functionality may cause damage to the Nest Box Gates The NEST BOX GATES Open and Close at certain times based on a TIME CLOCK setting only.
  • Page 31 Page 31 of 43 ChickenMaster PRO User Guide Firmware 01.14B Revision 1.0 23/05/2022 Main Settings Menu Nest Box Gates Open/Close Settings GATES CLOSE TIME Default value = 16:00 Main Settings Menu Nest Box Gates INSTALLER OPTIONS Installer Options allows the Installer and End User to be able to make critical changes to the NEST BOX GATES Settings.
  • Page 32 Most actuators have a travel stroke time from fully closed to fully open of approximately 45-50 seconds. Because the actuators are only two wire and do not have a position feedback, the ChickenMaster Pro cannot determine the actuators actual position.
  • Page 33 Page 33 of 43 ChickenMaster PRO User Guide Firmware 01.14B Revision 1.0 23/05/2022 This feature minimises major egg losses and hen stress if the NEST BOX GATES have failed to open because of a failing battery. The ALARM Front panel LED will flash and if the Strobe Alarm Indication option is ENABLED the external Strobe Light will flash.
  • Page 34: Internal Lighting

    TIME CLOCK settings occur at a fixed User entered time to turn the Internal Lighting On and Off in the morning and On and Off again in the evening. SUNRISE/SUNSET setting is calculated mathematically by the ChickenMaster PRO based on the Latitude and Longitude of the user’s current geographic location.
  • Page 35 Page 35 of 43 ChickenMaster PRO User Guide Firmware 01.14B Revision 1.0 23/05/2022 Main Settings Menu Internal Lighting AUTOMATIC MODE MODALITY Default value = SUNRISE/SUNSET AUTOMATIC MODE ON/OFF SETTINGS (When the TIME CLOCK Option is selected) Main Settings Menu Internal Lighting...
  • Page 36 Page 36 of 43 ChickenMaster PRO User Guide Firmware 01.14B Revision 1.0 23/05/2022 Main Settings Menu Internal Lighting Automatic Mode On/Off Settings EVENING ON TIME Default value = 17:00 Main Settings Menu Internal Lighting Automatic Mode On/Off Settings EVENING OFF TIME...
  • Page 37 Page 37 of 43 ChickenMaster PRO User Guide Firmware 01.14B Revision 1.0 23/05/2022 Once the correct PASSWORD has been entered the INSTALLER OPTION items are available with the following TWO options. Main Settings Menu Internal Lighting INSTALLER OPTIONS Enables/Disables this Feature...
  • Page 38: Event History

    Page 38 of 43 ChickenMaster PRO User Guide Firmware 01.14B Revision 1.0 23/05/2022 Main Settings Menu EVENT HISTORY Event Descriptions Time & Date Stamp Battery Voltage Event Number The EVENT HISTORY Screens display a record of events with a Date, Time & Battery Voltage stamp.
  • Page 39 Page 39 of 43 ChickenMaster PRO User Guide Firmware 01.14B Revision 1.0 23/05/2022 Restore to Factory Defaults & First Boot Up Default Values MENU Item Description Restore to First Boot Up and Factory Defaults ERASE ALL SETTINGS & DO FACTORY RESET...
  • Page 40 Page 40 of 43 ChickenMaster PRO User Guide Firmware 01.14B Revision 1.0 23/05/2022 MENU Item Description Restore to First Boot Up / and Factory Defaults ERASE ALL SETTINGS & DO FACTORY RESET (Courtesy Lights Continued….) VOLTAGE LOCKOUT AVAILABILITY ENABLED ENABLED VOLTAGE LOCKOUT VALUE 11.5 VOLTS...
  • Page 41 Page 41 of 43 ChickenMaster PRO User Guide Firmware 01.14B Revision 1.0 23/05/2022 SETTINGS OPEN GATES TIME 04:00 04:00 CLOSE GATES TIME 16:00 16:00 MENU Item Description Restore to First Boot Up / and Factory Defaults ERASE ALL SETTINGS & DO...
  • Page 42 If requested use access code 2022 and then complete the registration process to retrieve your Installer Password. NB: If you have more than ONE ChickenMaster PRO already registered it will be linked with your email address and return the same password as previous registrations. This avoids having multiple passwords to remember.
  • Page 43 “Dropped Pin” is displayed 3. Scroll down to see the displayed location coordinates. Note: Positive Values = North Latitude or East Longitude, Negative Values =South Latitude or West longitude You are now at the MAIN HOME SCREEN Your ChickenMaster PRO Initial Setup is now complete. 09:58:13 26 JUL 2021 Please refer to Page 42 of the Programming Guide to Battery LEVEL: 13.8V...

Table of Contents