Summary of Contents for QUANTOR MINICHILLY

  • Page 1 NSTRUCTION ANUAL OMPACT OOLING CHILLY / I CHILLY WTG-Quantor GmbH Europa-Allee 53 D-54343 Föhren Phone: +49 (0)6502 999 95-0 Fax: +49 (0)6502 999 95-75 eMail: info@quantor.technology Homepage: www.quantor.technology...
  • Page 2: Table Of Contents

    Table of contents Page 1. Safety instructions ......................2 1.1 Installation and commissioning ..................2 1.2 Safety information......................2 1.2.1 Impairment of safety ....................2 1.2.2 Safety instructions ......................3 1.3 Spare parts ........................3 1.4 Transport/Storage ......................3 1.5 Electrical installation ......................3 1.6 Service .........................3 2. Intended use ........................3 3.
  • Page 3: Safety Instructions

    1. Safety instructions 1.1 Installation and commissioning Place the unit on a plain, dry and clean place. Pay attention that the connecting cable is untangled and free and that nothing is resting on it. For direct product cooling use the cooling coil offered by the manufacturer only (optional item).
  • Page 4: Safety Instructions

    All information in this instruction manual regarding service work must be strictly observed. 2. Intended use The cooling units MiniCHILLY and IceCHILLY are suitable for the cooling in process for the production of beverages. With the additional stainless steel cooling coil (as option), liquids can be cooled directly (see safety instructions, min./max.
  • Page 5: Commissioning

    (unit and pipes). Never operate the unit with a liquid level beneath the lowest water level mark "min“ (at MiniCHILLY units) or the water tank must be filled with sufficient water all the time in order to protect the unit e.g. against damage to the pump.
  • Page 6: Decommissioning

    Expansion valve Submersible pump Condenser Hoses for water circuit Evaporator (cooling circuit) Water tank Cooling coil (optional) 4. Decommissioning  Switch off the unit and disconnect the power plug.  Remove the pipes/hoses from the unit.  Draining and cleaning of the unit by qualified personnel. 5.
  • Page 7: Buttons And Led

    1.0 Buttons and LED Eliwell To activate the LOC function: - Call up the "Basic commands" menu with the key. Within 2 seconds, press the "Standby )" and operate . If the LOC function is activated, the LOC display appears when an attempt is made to access the "Parameters"...
  • Page 8: Set Basic Function

    2.0 Set basic Function The WTG Quantor multifunction controller has three functions: APP 1 Ice bench controller APP 2 Temperature controller for wet cooler APP 3 Temperature controller for dry cooler The selected function is set when booting the controller: Press and hold, at the same time connect the power supply to the controller or the chiller.
  • Page 9: Troubleshooting

    7. Troubleshooting Error Possible cause Error correction    The unit No mains connection Establish main connection does not (plug the unit)   start No water in the tank Fill in water   Thermostat is disconnected Switch on the Thermostat ...
  • Page 10: Technical Data

    10. Declaration of conformity We, WTG-Quantor GmbH, D-54343 Föhren, declare in sole responsibility that the cooling units MiniCHILLY 03, MiniCHILLY 05, MiniCHILLY 09, MiniCHILLY 17, IceCHILLY 33 and IceCHILLY 77, which this declaration refers to, comply with the following standards and normative documents.