WARNING AND CAUTION While the instrument is operating, be careful not to expose your eyes to the • emitting laser beam. Exposure to a laser beam for a long time may be hazardous to your eyes (laser beam: equivalent to Laser Class 2 Standard). Do not try to dismantle the instrument.
Page 3
Introduction Congratulations on the purchase of your Linesite LSL 205 Series Laser. Although simple to use, we recommend that you read this manual before operating the laser. Description The Linesite LSL205 is ideal for general construction, site preparation, foundation building in medium working range. It automatically self-levels in horizontal condition.
Page 6
1.3 Main Panel Explanation (1) ON/OFF: Controlling the state of power. (2) Power indicator: Power indicator: When on, the instrument is starting up. Otherwise it is shutting down. (3) Mode indicator: When on, the instrument is leveling manually. When it blinks, it stays in alarm.
Page 7
2. Directions: 2.1 Instrument Placement 2.1.1 Horizontal Leveling Lay the instrument on the tripod or stable flat surface, or even hang it on the wall. Set upright the instrument and keep the slope of instrument within the range from -5°to +5°. 3.
Page 8
3.3.2 Leveling Press the Key ON/OFF to bring automatic leveling into function when the laser beam begins to wink. After automatic leveling, the laser module will rotate at the speed of 600r.p.m. If the instrument is placed improperly, or the slope of instrument exceeds the range of ±5°, at that moment mode indicator and the laser beam will wink together.
Page 9
4. Power When the voltage indicator lights, the batteries need to be charged immediately. Connecting the charger with AC, insert the plug of charger into the plughole at the bottom of the instrument (As depicted above). If the red indicator of charger lights, it shows the batteries are being charged.
Page 10
Notices: (1) Using included rechargeable battery pack of the instrument, recharging will be finished within 7 hours. (2) Power required for the charger: Frequency: 50-60HZ; Voltage: 100- 240VAC (3) Charging and using of the instrument can progress simultaneously. (4) If keeping the instrument in storage (or Leave the instrument unused for a long time), the batteries (dry battery or rechargeable battery) need to be taken out.
5. Horizontal Accuracy Checking (1) Place the instrument at the point of 50m in front of wall (or set a scale plate at the point of 50m away from the instrument), and then adjust the level of the base approximately to aim the X1 to the wall (or scale plate), as depicted below.
6. Specifications Leveling Accuracy (H) ±1.5mm at 10m Leveling Range ±5º Working Range with Receiver depending on (Diameter) Diameter:350m working environment Visible Working Range depending on working environment Laser Diode, Class 2 (IEC60825-1,2014) Light Source wavelength: 635-650nm Working Temperature -5℃-- +50℃ ℃- to +60℃...
Page 13
6. Specifications - Continued Approximately 20 hours Hours in continuous use (Rechargeable) RL IP IP 55 Dimension 160mm x 120mm x 120mm Weight 2.1kg Rough Band: 3mm/ Precise Band: Laser Detector Precision Laser Detector IP IP55 Laser Detector Power Supply...
Page 14
7. Item Checklist Item LSL-205 Rotary Laser level Hard carry case Rechargeable battery pack (Installed) Laser receiver with clamp Laser target Visibility glass Charger User manual...