CONTENTS PRODUCT INTRODUCTION TABLE OF CONTENTS WHEN SHOULDN’T DEVICE BE USED? POSSIBLE SIDE EFFECTS ROSSWAN PURE TREATMENT OVERVIEW WHAT TO EXPECT TREATMENT STEPS TROUBLESHOOTING LIMITED WARRANTY DEVICE SPECIFICATIO CUSTOMER SERVICE...
The light outlet of this product adopts sapphire mirror surface, wear-resisting and scratch-resistance, high light transmittance. Sapphire will be mainstream in the IPL PURE field in the future. Sapphire crystal has high thermal conductivity, it can be better to transfer heat, lower the temperature of sapphire, the light outlet of sapphire can be all-round cooled skin, reduce skin heat, avoid skin surface burning, to achieve painless PURE.
Page 5
READ THESE INSTRUCTIONS BEFORE USE Before you use your new ROSSWAN PURE device, read this booklet for important information: · Confirm that the ROSSWAN PURE device is safe for you · Learn how to use the ROSSWAN PURE device · View our treatment results timeline ·...
Page 6
IPL Technology-How does it work The ROSSWAN PURE is based on the advanced IPL technology. The light penetrates the epidermis to the dermis and is absorbed by the melanin in the hair shaft. The heat generated by the absorbed light then dissipates into the follicle and generates local thermal damage, causing a reduction in hair growth.
TABLE OF CONTENTS GETTING TO KNOW YOUR ROSSWAN PURE DEVICE What the ROSSWAN PURE Device is used for? ROSSWAN PURE Device Description PURE Handheld Display User Interface Description WHEN SHOULDN’T ROSSWAN PURE BE USED? Who should not use ROSSWAN PURE device...
Page 8
Preliminary test How to treat Post-treatment care Recommend treatment protocol TAKING CARE OF YOUR ROSSWAN PURE Cleaning instructions Long-term storage TROUBLESHOOTING LIMITED WARRANTY CUSTOMER SERVICE DEVICE SPECIFICATION PARAMETERS...
Page 9
ROSSWAN PURE device description The ROSSWAN PURE device consists of the following main components: ROSSWAN PURE Handheld Device • Protective Glass • Shaving Knife • Handheld description 【Parts Name】 ①Light Outlet ②Air Outlet ③Display Screen ④Power Button/Gear Button ⑤Indicator Light...
Page 11
User Interface Description The user interface and control capabilities include the following features: ON/OFF and energy selection button Single button used for the device activation, deactivation, and energy • selection. Long pressing the button (after the device is connected to the power •...
Page 12
ROSSWAN PURE is intended for use on all treatment areas, such as • the legs, underarma, bikini line, back and arms. ROSSWAN PURE is intended for use on skin tone type 1 to 4 • according to Fitzpatrick skin chart below.
Who should not use ROSSWAN PURE device - CONTRAINDICATIONS Do not use the ROSSWAN PURE device if you are under the age of 18. The use of ROSSWAN PURE device on or by children has not been established and could result in serious injury.
Page 14
Retinoid acid, Retina-A, Vitamin A such as Accutane as it consider to be a photo-sensitive drug and may result serious skin injury. Do not use the ROSSWAN PURE device if you are photosensitive or have other diseases related to light sensitivity as it may lead to serious injury.
Page 15
ROSSWAN PURE device as it may cause burning of the skin. Do not use the ROSSWAN PURE device if you have an active implant such as a pacemaker, insulin pumps, or similar devices since it may cause interference.
Page 16
Do not use the ROSSWAN PURE device if you have dark brown or black spots such as freckles, birth marks, around the nipples, moles or blisters on the area to be treated. Do not use ROSSWAN PURE device on mucous membranes such as nostrils, lips of the mouth, eyelids, ears, genital area and the anus as it may lead to serious injury.
Page 17
Do not treat the same area of skin more than once per treatment as it may cause skin irritation. *NOTE: Do not share ROSSWAN PURE device at any time, due to the possibility of transmitting diseases between users.Use ROSSWAN PURE device only with its original power supply. For your safety, never...
POSSIBLE SIDE EFFECTS When using the ROSSWAN PURE device according to the instructions for use, side effects are rare. However, every aesthetic procedure including the usage of home use devices may cause some degree of side effects. Therefore it is...
Page 19
Skin burns -Rarely, burns on the treated area can occur following the use of the PURE reduction system. The burns can require a few weeks to heal and, extremely rarely, may leave a visible permanent scar. Scarring -In rare cases, permanent scarring may occur. Usually when scarring occurs it is in the form of a flat and white lesion on the skin (hypotrophic).
Page 20
Bruising -Blue-purple bruising is exceedingly rare by using the ROSSWAN PURE device and can last 5 to 10 days. As the bruising fades, there may be a rust-brown discoloration of the skin (hyperpigmentation) that can be permanent.
Before each treatment *24 hours before each treatment, shave the treatment area. *Cleanse, shave, and dry your skin(see guidance at Prepare your skin page) *Turn on the ROSSWAN PURE *Set the treatment level Between treatments *Shave, but don’t wax or plux hair Treat until you’re done...
Page 22
Dry the treatment area. *Note: Never use flammable liquids such as alcohol (including perfumes, sanitizers, or other applications containing alcohol) or acetone to clean the skin one hour before using ROSSWAN PURE device as it may cause burning of the skin.
Preliminary test *The preliminary test is intended to determine your skins reaction to the ROSSWAN PURE device treatment and help you set the optimal energy level for each treatment area. Do a preliminary test on each area you intend to treat 48 hours prior to the full treatment.
Page 24
Select the lowest level and deliver a pulse on the selected preliminary test skin area. If you feel comfortable with the energy level, increase it to level 2 and perform an additional pulse on the next spot. Only if you feel comfortable, you may reach the maximum energy level of 9.
Page 25
Display Screen Introduction unlimited flash for personal use Ice Cooling Gear Auto Flashing 1. Switch among different functions, the corresponding icon will light up, ice cooling will be turned on automatically when power on. 2. Gear instructions. Display the energy level with a single number in the middle.
Page 26
Before the first use Before using, please make sure that which energy level is suitable for your skin and the area you want to remove the hair. PURE instrument has 9 energy level, from level 1 (lowest) to level 9 ( highest).
TREATMENT STEPS Before treatment, please shave off the hair in the area that needs to be depilated, then clean and wipe it. This can ensure that hair follicles under the skin absorb the light energy to the maximum, then the hair can be removed thoroughly.
Page 28
Turn on the device and lightly touch Auto flash button, it will be switched to automatic Auto flash mode, then you just need to press the light outlet closely against the skin, the PURE device will emit light automatically. Attention: When the device is in Auto flash mode, never touch the light outlet with your body parts that need to be depilated or other people.
Page 29
switch manual light-emitting In Auto flash mode, lightly touch Auto flash button, the device will be switched to manual flash mode. .Keep the light outlet close to the area where you need to remove the hair, and try to place the device at a 90° angle on the skin ①When the device is in manual mode, wait for the indicator lights up, press and release the flash button to emit the flashing light, the treatment is finished for the area covered by the light outlet.
Page 30
12. After cleaning the device, put it back into packing box. Place it in a dry and well-ventilated area where is out of reach of children. 13. The treated skin care: clean the treated skin after finishing treatment 20 minutes, then you can moisturize the skin with the moisturizing skin care product.
Page 31
White to Arms and then treat every light 8-12 2 weeks for up to inclusive brown Underarms 3 months Bikini lines until you see the dedired results *Note:Response ROSSWAN PURE device hair reduction differs between individuals, depending on biological factors.
Page 32
Be careful not to damage the treatment window. Allow to dry completely before turning on your ROSSWAN PURE DO NOT get the ROSSWAN PURE wet. If it gets wet, DO NOT use the ROSSWAN PURE.Performing a treatment with a wet ROSSWAN PURE...
Page 33
Long-term storage If you do not plan on using your device for a long period of time, we recommend that you turn on the device every 3 months to maintain the life of the device.
TROUBLESHOOTING If you experience any problems with the ROSSWAN PURE device, please refer to below information to try to resolve it. YOUR QUESTION HOW TO TROUBLE SHOOT Make sure that the power supply is plugged properly • If ROSSWAN PURE device into ROSSWAN PURE device and the electrical outlet.
The limited warranty begins on the date of purchase and expires one year later. The warranty period is not extended for any period during which the ROSSWAN PURE device (or any parts thereof) is in repair or if your ROSSWAN PURE device is replaced by ROSSWAN during the...
Page 36
(ii) repair your ROSSWAN PURE device using either new or refurbished parts. If we find that the defect in your ROSSWAN PURE device is not covered under this limited warranty, we will notify you about the service alternatives that are available on a fee basis.
Page 37
This limitation does not apply to claims for death or personal injury caused by a defect in the ROSSWAN PURE device or any other liability that cannot be excluded or limited by law.
Page 38
ROSSWAN and you, the purchaser of the ROSSWAN PURE device.This allocation is recognized by both parties and is reflected in the price of the ROSSWAN PURE device. By using the ROSSWAN device, you acknowledge that you have read these terms, conditions, and limitations, understand them, and are bound by them.
Page 39
Miscellaneous terms As used in this contract, “our” “we” and “us” refer to ROSSWAN PURE. “You” refers to the original purchaser of the ROSSWAN PURE device. A waiver of strict compliance with any term here in shall not be deemed a continuing waiver or waive any other terms or conditions.
CUSTOMER SERVICE For more information about ROSSWAN PURE device or if your ROSSWAN PURE device is broken, quits working or you need more assistance, please contact us: Email: support@rosswanbeauty.com Warranty Self-purchase Arrival date of goods period within one year Name...
Need help?
Do you have a question about the PURE and is the answer not in the manual?
Questions and answers