Page 1
SPRING HAND DYNAMOMETER(SH5002) User Manual...
Page 2
INSTRUCTIONS FOR USE SAEHAN SPRING HAND DYNAMOMETER SH5002 GENERAL: This device is to measure hand grip strength and used to secure an index of general upper body strength adjust the hand grip size to exert the subject’s maximum grip. Move pointer lever to zero with your finger allow three trials with each hand alternating.
Page 3
INFORMATION ON COMPONENTS, PACKAGE CONTENT : Name Function Dial Face Scale measures up to 100kg(220 lbs) Keep spring securely Pointer Pointer on the dial indicates force exerted Handle Grip Handle for gripping, Adjustable for hand size Base Base for handle Grip size Scale Adjustable for hand size scale Knob...
Page 4
Scope of supply : - Device - Soft case - Operating instructions...
SAFETY PRECAUTION : Carefully read this operation manual before setup, even if you are already familiar with SAEHAN Spring dynamometer. Precautions for use Do not set the handle grip to a position less than 4 cm as shown by the grip size scale.
Page 6
much force as possible being careful to squeeze only once. Record the resultant scale reading. 4. Allow three trials with each hand, right and left hand alternating. There should be a brief pause of about 10 to 15 seconds between each trial to avoid excessive fatigue. Record the amount registered at each trial, but use only the highest recorded for each hand.
Page 7
CHILDREN DATA FOR SPRING GRIP TESTER TABLE 1 Averages of Strength of Grip, In kg. for childrn ADULT DATA FOR SPRING GRIP TESTER TABLE 2 Averages of Strength of Grip, In kg. for ADULT...
Changes to the unit’s design are not permitted. This may lead to incorrect measuring results, safety-related faults and destruction of the device. The device may only be operated in accordance with the described default settings. Other areas of use must be released by SAEHAN. SPECIFICATIONS : Measurement range...
Remove dirt immediately. Service, maintenance : The appliance may only be opened by trained service technicians who are authorized by SAEHAN. Annual Calibration and Repair : It is recommended that this instrument be checked for accurate calibration annually. If the instrument has been dropped or there is reason the suspect that calibration is required, the instrument should be serviced immediately.
Page 10
Symbol description : Definition of using symbols Symbols Meaning Manufacturer Date of manufactured Authorized representative in the European Community Medical device Serial number Batch code Catalogue number Caution Fragile, handle with care Keep dry Keep away from sunlight Consult instructions for use ※...