Summary of Contents for Getein Biotech Getein1100
Page 3
Warnings, Precautions and Limitations a. Read this user manual carefully to obtain optimum performance from your analyzer. b. Only used for in vitro diagnostic analysis of human whole blood, plasma, serum and urine. c. To avoid fire, electric shock or personal injury, please turn off the power immediately and disconnect the power plug when the analyzer emits abnormal odor, smoke or any liquid seeps into the instrument.
Page 4
Symbols & Description Manufacturer Consult instructions for use Caution, consult accompanying documents Serial number This way up Fragile In vitro diagnostic medical device Authorized representative in the European Community Biological risks CE Mark Keep away from sunlight Keep away from rain Maximum number of identical packages which may be stacked on one another is “4”...
Getein test kits including markers for cardio- vascular diseases, renal diseases, inflammation, fertility, diabetes mellitus, bone metabo- lism, tumor and thyroid. This manual contains instructions for the use of Getein1100 and general instructions for testing specimens and quality control materials.
1.3.2 Working Principle The detection element scans the binding area and converts the optical signal to electrical signal. The voltage variation between test line and background has a linear relationship with the antigen concentration which can be used to calculate the concentration. In conclusion, the antigen concentration in whole blood, plasma, serum, urine can be calculated quantitatively according to the optical signal of the test line.
2.1 Unpacking Check the analyzer and accessories refer to the packing list (Table 2-1). If you find any parts missing or any other questions, contact with your agent or Getein’s after-sales engineer directly. Table 2-1 Getein1100 Packing List Description Model Unit...
2.2 Analyzer Configuration Getein1100 is composed of control system, optical system, display unit, analog signal acquisition system, mechanical drive system, etc. Front and rear view of Getein1100 are showed in Fig.2-2 and Fig.2-3. Fig.2-2 Front View of Getein1100 Fig.2-3 Rear View of Getein1100 2.3 Main Interface...
Operating Detection Range Resolution Model Wavelength (nm) (mV) (mV) Getein1100 635 ± 5 0 ~ 15000 2.4.2 Performance Indexes Blank Count Voltage of the blank QC card should be less than 100 mV Linearity r ≥ 0.95 in the detection range from 0 mV to 3200 mV Repeatability CV ≤...
Dry, clean, flat and horizontal surface away from direct sunlight, wind, hot source, noise source, power interferences, electronic brush type engine and mechanical vibration. 2.5.2 Space Requirement Place Getein1100 at a horizontal position and reserve enough space for the reagents.
2.6.4 Power Connection 1) Use the adapter packed together with Getein1100. Power supply: AC100V ~ AC240V ± 10%, Frequency: 50~60Hz ± 1Hz. 2) Connect power with Getein1100 through the AC/DC adapter. 3) Press the power switch to turn on the analyzer.
3. Operation 3.1 Preparations before Power On Please confirm whether the analyzer is ready for use according to the following steps before turning on the switch. 1) Check whether the power supply is ready or connected safely. 2) Check whether the printing paper is enough or paper installation is OK. 3.2 Power On Press the switch to turn on the analyzer, then system will start its self-checking and then enter the Test Interface.
3.3 Quality Control Calibration To guarantee the accuracy of measurement and the comparability of data, calibration is required before running patient samples. Please use corresponding SD card to calibrate the analyzer before testing different batches of kits (Note: SD card for different batches cannot be exchanged).
Page 16
Fig.3-3 Sample Measurement Procedure Note: 1) Do not change the interface during the measurement. 2) Different items have different sample volume and reaction time, please refer to the user manual of specific items carefully for accurate information.
3.5 Result Query 3.5.1 Query Click on “Search” icon to switch to result query interface, there are three ways to query results (Fig.3-4). Input name or sample ID here Fig.3-4 Search Interface 1) Input full or part of the Name or Sample ID (Fig.3-5). Search by name: hs-CRP+CRP 10 mg/L Search by sample ID:...
2) Select required Date & Time (Fig.3-6). Search by date ( Fig.3-6 Date & Time Search Interface 3.5.2 Result Deletion User can delete the unwanted result by selecting the certain result and sliding to the left side. Click “Delete” and a remind will be shown in the following interface (Fig.3-7). Then Click “OK”...
Delete Fig.3-7 Record Deleting Interface 3.5.3 Test Report Click on the required record for detailed test report (Fig.3-8). In the test report interface, three icons named “Print”, “Save” and “Upload” are listed. Slide to the left side to view the test voltage waveform.
Page 21
Patient information is editable in case that user forgets to input or input wrong information while No., test item and result are not editable (Fig.3-9). Fig.3-9 Patient Information Edit Procedure...
2) Communication Mode includes Serial Port and WiFi. 3) Communication Protocol should be selected by or with the assistance of personnel. 4) Communication Timeout (10 s, 30 s, 1 min and 5 mins) can be selected as the discon nection standard of Getein1100 with upper computer system.
Press to test whether this function is OK. Fig.4-2 Communications Setting Interface 4.2 Print Setting Mainly include Auto Print Status and Print Test (Fig.4-3). Press to test whether this function is OK. Fig.4-3 Print Setting Interface...
4.3 Test Setting Mainly include Sample and Test Mode (Fig.4-4). Urine Inside Mode Outside Mode Fig.4-4 Test Setting Interface 4.4 Reaction Time In this interface, the reaction time imported from SD card will be displayed (Fig.4-5). Note: Do not change the reaction time manually unless it is wrong. Fig.4-5 Reaction Time Interface...
4.5 System Setting Mainly include Screen Saver, Language, System Date/Time and Factory Reset (Fig.4-6). When this function is on, the screen will be dark if no operation is done within 5 minutes. English, Chinese, Español and Português are available. Set to local time. Click to reset to defaults when parameters are garbled or debug is needed.
4.7 Debug Mode Debug Mode is for engineers only Fig.4-8 Debug Mode Interface 4.8 Screen Wakeup User can awake the analyzer by tapping the screen gently. 4.9 Shutdown In any interface, user can press the switch to shut off the analyzer directly. 4.10 Waste Disposal Waste liquids, test cards, consumables and other wastes are considered as medical waste, source of infection and industrial waste, please handle properly in accordance with...
5.2 Software Version Software name: GP Information Management Software Model: Getein1100 Version: Refer to the practical 5.3 Environmental Requirements 5.3.1 Hardware Environment CPU ≥...
1) Please place the analyzer at a horizontal position for good operation. 2) Under power outage situation, please wait for 30 seconds before restarting the analyzer. 3) Only reagents supplied by Getein can be used on Getein1100. Refer to the specific user manual for more details.
6.3 Troubleshooting If there is a malfunction during the operating process, alarm prompts will pop up. Error Cause Solution Check the shelf life and test again Invalid test card No C line or shallow C line with a new card Sample mode Inconsistent test item and Switch sample mode, re-measure...
4) Suggest using only as directed. Getein will not responsible for efficiency protection caused by operations out of accordance with user manual. 7.4 Analyzer Lifespan The lifespan of Getein1100 is 8 years (continuous working time no more than eight hours every day) under standardized operation and proper maintenance.
Page 31
Getein Biotech, Inc. Add: No.9 Bofu Road, Luhe District, Nanjing, 211505, China Lotus NL B.V. Add: Koningin Julianaplein 10, 1e Verd, 2595AA, The Hague, Netherlands. Tel: +31645171879(English), +31626669008(Dutch) Email: peter@lotusnl.com...