5.

Configuration

5.1.

Default Configuration

Every Total Recall VR leaves the factory with a default configuration which enables it
to start recording the minute it is powered up.
In summary the default configuration is:
 The ID of the Total Recall VR is set to 1. If you have multiple Total Recall VRs
we recommend that you assign a different ID to every Total Recall VR.
 The time zone is set to Australian Eastern Standard Time. The time and date are
set to the current time and date in Sydney, Australia. We recommend that you
change the time zone before starting to record.
 The default passwords for the administrator and the standard user are set to
'0000'. We recommend that you change both to improve the security of Total
Recall VR.
 The LAN 1 interface has an IP address of 192.168.1.100/24.
 The LAN 2 interface has an IP address of 192.168.2.100/24.
 The Remote Interface accepts connections from client applications on IP address
192.168.1.100 and TCP port 10010.
 All recordings will be kept when recorded irrespective of their duration.
 Recordings will not be deleted based on their age, but will be deleted when the
occupancy of the disks reaches 95% or more, or the number of recordings in
reaches 600,000 or more.
 All SIP calls that are detected on the network that is connected to the LAN 2
interface will be recorded and kept.
 Automatic archiving of recordings is not enabled.
The following list is a summary of the default factory configuration.
General Settings
Language
Time & Date
Use NTP
NTP Address 1
NTP Address 2
Date
Time
English
No
0.0.0.0
0.0.0.0
Current date in Sydney, Australia
Current time in Sydney, Australia