  • Page 1 User manual 875345 MF4.1 Multiformat Switch 4/1...
  • Page 2: Table Of Contents

    Limitations of Warranty ..................12 Exclusive Remedies ..................13 RMA Policy ...................... 13 Standard Replacement ..................14 Once you have obtained an RMA number ............14 Please note: ..................... 15 Warranty ......................15 Return and RMA Policies ................. 16 Relens GmbH Contact: info@relens.de 2...
  • Page 3: Safety Information

    If the wall plug does not fit into your local power socket, hire an electrician to replace your obsolete socket. This equipment should be installed near the socket outlet and the device should be easily accessible in the case it requires disconnection Relens GmbH Contact: info@relens.de...
  • Page 4: Introduction

    Support RS232/Button/Contact closure for switching; • Support Auto/Manual switching mode; • Analog audio de-embedded at the output; • Support output mute function; • Support power standby mode; • Status LED for all connections on front • Relens GmbH Contact: info@relens.de 4...
  • Page 5: Panel Description

    6. PWR: Solid Red when power on; 7. SELECT: Button for switching input signal. Pressing for 3-5secondor longer to toggle EDID selection。 HD3-O flash once to indicate switching to internal EDID, HD-O flash 3 times mean switching to external display EDID. Relens GmbH Contact: info@relens.de...
  • Page 6 2. VGA: VGA Input 3. AUD: VGA Audio Input; 4. DP: Display PortInput; 5. HDMI-A/B: HDMI Inputs; 6. HDMI: HDMI Output; 7. AUD: Analog Audio Output; 8. Phoenix Port: RS232 and Contact Closure with LED indicator. Relens GmbH Contact: info@relens.de 6...
  • Page 7: Application Diagram

    875345 MF4.1 Application Diagram Relens GmbH Contact: info@relens.de...
  • Page 8: Specifications

    0.33 KG Operating Temperature 0°C to 55°C Storage Temperature - 20°C to 85°C Power Supply 5V/1A DC Package Contents  1×Base Unit MF4.1  1×5V 2A DC power adapter  1×User manual  2×Wall mounting bracket Relens GmbH Contact: info@relens.de 8...
  • Page 9: Rs232

    = 0 , 1 Mute the Mute the 0 = Mute &Va<cr> HDMI &V0<cr> Mute On HDMI Output Output, 1 = Output UnMute Output Request Channel Query Active &R?<cr> ing the &R?<cr> status Route active Current Relens GmbH Contact: info@relens.de...
  • Page 10 = Switching to preset EDID a = ? Request Requesting ing the the EDID EDID: EDID?<cr> ? = Switching EDID EDID?<cr> Status, external to preset EDID Status, Feedback Feedback Note: The default baud rate 9600. Relens GmbH Contact: info@relens.de 10...
  • Page 11: Phoenix Connection Diagram

    875345 MF4.1 Phoenix contact connection diagram. Note: VGA Input LV: LED indicator for VGA DP Input LED indicator for DP HA: HDMI-AInput LA: LED indicator for HDMI-A HB: HDMI-B Input LB: LED indicator for HDMI-A Relens GmbH Contact: info@relens.de...
  • Page 12: Maintenance

    Warranty Policy Relens products are warranted against defects in material and workmanship for two years from the date of shipment. During the warranty period, Relens will, at its option, repair or replace products that prove to be defective. Repairs are warranted for the remainder of the original warranty or a 90 day extended warranty, whichever is longer.
  • Page 13: Exclusive Remedies

    The warranty does not cover replacement or repair necessitated by loss or damage from any cause beyond the control of Relens, such as lightning or other natural and weather related events or wartime environments. The warranty does not cover any labor involved in the removal and or reinstallation of warranted equipment or parts on site, or any labor required to diagnose the necessity for repair or replacement.
  • Page 14: Standard Replacement

    After obtaining an RMA number from Relens, you must send the product - freight prepaid - to Relens. The Relens RMA number must be prominently displayed on the outside of your package. If you send your product to Relens without the RMA number prominently displayed on the outside of the package, it will be returned to you unopened.
  • Page 15: Please Note

    Shipping your RMA to Relens using regular mailing envelopes is not acceptable, as they do not protect the product from damage during shipping. Relens will not repair or replace a module that is shipped in such a way that the product is not properly protected.
  • Page 16: Return And Rma Policies

    875345 MF4.1 Return and RMA Policies Shipments will not be accepted and processed for warranty repair/replacement without an Relens RMA(Return Materials Authorization). All data are subject to errors and amendmends Relens GmbH An der Eiche 4 33175 Bad Lippspringe info@relens.de www.relens.de...