KILLION CFFM-93-57-99 Installation And Operating Instructions Manual

Refrigerated bulk floral

Advertisement

Rev. 2013-09-25
REFRIGERATED BULK FLORAL MERCHANDISER
INSTALLATION AND OPERATING
SAFETY FIRST
1.
Read these instructions thoroughly before installing merchandiser.
2.
Heed all warning labels and stickers.
3.
Electrical work should be performed by Qualified Electricians only.
4.
Display Cases are shipped with generic settings. Therefore, a Qualified
Refrigeration Service Technician should properly adjust case settings for each
store's unique ambient conditions if necessary.
5.
Disconnect power before servicing. Merchandiser contains moving parts.
6.
Self-contained merchandisers should be allowed a minimum of 4 hours to stabilize
before power is applied.
7.
Only Qualified Refrigeration Service Technicians should perform service work on
Killion merchandisers.
www.killionindustries.com • Sales@killionindustries.com • Parts.Service@killionindustries.com
CFFM-93-57-99
INSTRUCTIONS
Call Killion for technicians in your area.
ATTENTION
READ INSTALLATION & OPERATING
INSTRUCTIONS THOROUGHLY BEFORE
OPERATING THE MERCHANDISER.
ATTENTION
LISEZ LE & D'INSTALLATION ; CONSIGNES
D'UTILISATION COMPLÈTEMENT AVANT D'ACTIONNER
LE MARCHANDISEUR.
Killion Industries, Inc. • 1380 Poinsettia Ave., Vista, CA 92081
Phone (760) 727-5102 • Toll Free (800) 421-5352 • Fax (760) 727-1622

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the CFFM-93-57-99 and is the answer not in the manual?

Questions and answers

Summary of Contents for KILLION CFFM-93-57-99

  • Page 1 ATTENTION LISEZ LE & D'INSTALLATION ; CONSIGNES D'UTILISATION COMPLÈTEMENT AVANT D'ACTIONNER LE MARCHANDISEUR. Killion Industries, Inc. • 1380 Poinsettia Ave., Vista, CA 92081 Phone (760) 727-5102 • Toll Free (800) 421-5352 • Fax (760) 727-1622 www.killionindustries.com • Sales@killionindustries.com • Parts.Service@killionindustries.com...
  • Page 2: Table Of Contents

    Relocating / Moving TROUBLESHOOTING Troubleshooting Check List WARRANTY Warranty APPENDIX Resetting the LAE Refrigeration Controller Killion Industries, Inc. • 1380 Poinsettia Ave., Vista, CA 92081 Phone (760) 727-5102 • Toll Free (800) 421-5352 • Fax (760) 727-1622 www.killionindustries.com • Sales@killionindustries.com • Parts.Service@killionindustries.com...
  • Page 3: Pre-Installation

    Lisez la SECTION d'INSTALLATION entière avant de placer l'unité dans son endroit final. Killion refrigerators are Type 1 Open Display Refrigerators and designed to operate in air-conditioned stores where temperature and relative humidity are maintained at or below 75°F dry bulb temperature and 55% relative humidity.
  • Page 4: Plumbing Requirements

    This receptacle must be located within eight feet of the upper back of the refrigerated display case. It is highly recommended against using an extension cord with the refrigerated display case. Killion Industries, Inc. • 1380 Poinsettia Ave., Vista, CA 92081 Phone (760) 727-5102 • Toll Free (800) 421-5352 • Fax (760) 727-1622...
  • Page 5: Installation

    Refrigerated Display w/ High Volume Condensate Pump 1. Move the refrigerated merchandiser into desired position. 2. Attach the disconnect fitting (supplied by Killion Industries) to the end of the drain line coming down from the ceiling. 3. Locate the flex tube from the high volume condensate pump with the disconnect fitting attached.
  • Page 6: Maintenance

    Check refrigerant level through sight glass (located near the condensing unit), if bubbles are visible, the unit is low on refrigerant. (Call a qualified refrigeration service technician for service). Killion Industries, Inc. • 1380 Poinsettia Ave., Vista, CA 92081 Phone (760) 727-5102 • Toll Free (800) 421-5352 • Fax (760) 727-1622...
  • Page 7: Lighting

    Set the switch to the “Winter” setting during cooler weather to raise the case’s temperature to prevent product freezing. Killion Industries, Inc. • 1380 Poinsettia Ave., Vista, CA 92081 Phone (760) 727-5102 • Toll Free (800) 421-5352 • Fax (760) 727-1622...
  • Page 8: Stocking / Product Load Limits

    Be sure that all plumbing and electrical connections are disconnected before attempting to relocate the case. Follow all directions in the Pre-Installation and Installation sections when placing the unit in its new location. Killion Industries, Inc. • 1380 Poinsettia Ave., Vista, CA 92081 Phone (760) 727-5102 • Toll Free (800) 421-5352 • Fax (760) 727-1622...
  • Page 9: Troubleshooting

    2. Do the store conditions exceed 75° F / 55% relative humidity? Killion Type 1 Refrigerated Display Cases are not designed to operate in conditions exceeding 75° F / 55% relative humidity.
  • Page 10: Warranty

    Warranty shall be limited to repairing or replacing, at its option, any part of the Fixture which proves thus defective within one year from the date of invoice, and which KILLION’S examination discloses to its satisfaction to be thus defective.
  • Page 11: Appendix

    5. Tap the “x” button to return the controller to normal operation. All parameters are now returned to the default factory settings. Should you have any questions call Killion Customer Service at 1-800-421-5352 x120 or email at parts.service@killionindustries.com Killion Industries, Inc. • 1380 Poinsettia Ave., Vista, CA 92081 Phone (760) 727-5102 •...