Page 2
This laboratory accessory is perfect for demagnetizing forceps, screwdrivers, as well as other microsurgical instruments and parts. It can also magnetize tools, such as forceps, which can come in handy when working with small screws that can disappear when dropped. This magnetizer has a high power to weight ratio and is housed in a non-breakable plastic case.
PRODUCT FEATURES: 2.25 Inches Depth 3.5 Inches Height 4.8 Inches Width One Push Button 8 Feet Rubber Feet Operation Cord Length to stabilize unit finescience.com...
Page 4
TO DEMAGNETIZE: 1. Hold the item to be demagnetized inside the center of the housing opening. Use caution to ensure the part is not touching the housing. 2. Press and hold the button and withdraw the item slowly in a straight line from the housing opening for approximately three inches, keeping the item in line with the center of the housing opening, then release the button.
Page 5
TO MAGNETIZE: 1. Position the item to be magnetized inside and touching the sides of the housing opening. 2. Press and hold the button for four or five seconds then release the button. 3. The item should now be magnetized. Repeat procedure as necessary. finescience.com...
DUTY CYCLE: • This unit has superior field strength due to the relatively high amperage it draws. The consequence is a fairly rapid heating of the field coil. It is recommended that a single duty cycle be limited as follow: 5 seconds on and 3 minutes off, or three 5 second cycles on then 10 minutes off.
CONTACT INFO: Fine Science Tools (USA) Inc. 4000 East 3rd Avenue, Suite 100 Foster City, CA 94404-4824 Telephone: +1 800-521-2109 / +1 650-349-1636 Fax: +1 800-523-2109/+1 650-349-3729 E-Mail: info@finescience.com Web: finescience.com Fine Science Tools (CAN) Inc. 410-197 Forester Street North Vancouver, British Columbia Canada V7H 0A6 Telephone: +1 800-665-5355 / +1 604-980-2481...
Page 10
Dieses Laborzubehör ist ideal zum Entmagnetisieren von Pinzetten, Schraubendrehern sowie anderen mikrochirurgischen Instrumenten und Teilen. Es kann auch Werkzeuge wie beispiels- weise Pinzetten magnetisieren. Dies ist bei der Arbeit mit kleinen Schrauben nützlich, die schwer wiederzufinden sind, wenn sie heruntergefallen sind. Dieses Magnetisierungsgerät hat ein hohes Leistungsgewicht und ist in einem unzerbrechlichen Kunststoff- gehäuse untergebracht.
Page 11
PRODUKTMERKMALE: 5,72 cm (2,25 Zoll) tief 8,89 cm (3,5 Zoll) hoch 12,19 cm (4,8 Zoll) breit Betrieb mithilfe Kabellänge Gummifüße zur eines rund 2,5 Meter Stabilisierung Drucktasters (8 Fuß) des Geräts finescience.com...
Page 12
ENTMAGNETISIEREN: 1. Halten Sie den zu entmagnetisierende Gegenstand in die Mitte der Gehäuseöffnung. Achten Sie darauf, dass der Gegenstand das Gehäuse nicht berührt. 2. Halten Sie die Taste gedrückt und ziehen Sie den Gegenstand langsam in einer geraden Linie etwa acht Zentimeter aus der Gehäuseöffnung heraus, wobei Sie den Gegenstand in der Mitte der Gehäuseöffnung halten müssen, und lassen Sie dann die Taste los.
Page 13
MAGNETISIEREN: 1. Positionieren Sie den zu magnetisierenden Gegenstand im Inneren der Gehäuseöffnung und berühren Sie dabei die Seiten der Öffnung. 2. Halten Sie die Taste vier oder fünf Sekunden lang gedrückt und lassen Sie sie dann los. 3. Der Gegenstand sollte nun magnetisiert sein. Wiederholen Sie den Vorgang nach Bedarf.
Page 14
ARBEITSZYKLUS: • Dieses Gerät hat aufgrund der relativ hohen Stromaufnahme eine höhere Feldstärke. Das führt dazu, dass sich die Feldspule relativ schnell erwärmt. Es wird empfohlen, einen einzelnen Arbeits- zyklus wie folgt zu begrenzen: 5 Sekunden ein und 3 Minuten aus, oder drei 5-Sekunden-Zyklen ein und 10 Minuten aus.
Page 15
KONTAKTDATEN: Fine Science Tools (USA) Inc. 4000 East 3rd Avenue, Suite 100 Foster City, CA 94404-4824 Telefon: +1 800-521-2109 / +1 650-349-1636 Fax: +1 800-523-2109/+1 650-349-3729 E-Mail: info@finescience.com Web: finescience.com Fine Science Tools (CAN) Inc. 410-197 Forester Street North Vancouver, British Columbia Canada V7H 0A6 Telefon: +1 800-665-5355 / +1 604-980-2481...
Page 17
Manuel d’utilisation 中 文 du démagnétiseur 版 N° d’art. 18000-15...
Page 18
Cet accessoire de laboratoire est parfait pour démagnétiser les pinces, les tournevis ainsi que d’autres instruments et pièces de microchirurgie. Il peut également magnétiser des outils tels que des pinces, qui peuvent être utiles lorsque vous travaillez avec de petites vis qui peuvent disparaître lorsqu’elles sont lâchées. Ce magnétiseur présente un rapport puissance/poids élevé...
Page 19
I CARACTÉRISTIQUES DU PRODUIT : 61 cm de profondeur 91,5 cm de haut 122 cm de largeur Une simple Cordon Pieds en caoutchouc pression d’alimentation pour stabiliser le de bouton d’env. 2,4 m dispositif finescience.com...
Page 20
POUR DÉMAGNÉTISER : 1. Maintenez la pièce à démagnétiser au centre de l’ouverture du boîtier. Veillez à ce que la pièce ne touche pas le boîtier. 2. Appuyez sur le bouton et maintenez-le enfoncé et retirez lentement la pièce en ligne droite de l’ouverture du boîtier pendant environ huit centimètres, en maintenant la pièce en ligne avec le centre de l’ouverture du boîtier, puis relâchez le bouton.
Page 21
POUR MAGNÉTISER : 1. Placez la pièce à magnétiser au centre de l’ouverture du boîtier. 2. Maintenez le bouton enfoncé pendant quatre ou cinq secondes, puis relâchez le bouton. 3. La pièce devrait maintenant être magnétisée. Répétez la procédure si nécessaire. finescience.com...
Page 22
CYCLE D’UTILISATION : • Ce dispositif a une force de champ supérieure en raison de l’ampérage relativement élevé qu’il consomme. Il en résulte un échauffement assez rapide de la bobine de champ. Il est recommandé de limiter un cycle d’utilisation comme indiqué ci-après : 5 secondes allumées et 3 minutes éteintes, ou trois cycles de 5 secondes allumées puis 10 minutes éteintes.
Page 23
COORDONNÉES : Fine Science Tools (USA) Inc. 4000 East 3rd Avenue, Suite 100 Foster City, CA 94404-4824 Téléphone : +1 800-521-2109 / +1 650-349-1636 Fax : +1 800-523-2109/+1 650-349-3729 E-Mail : info@finescience.com Site web : finescience.com Fine Science Tools (CAN) Inc. 410-197 Forester Street North Vancouver, British Columbia Canada V7H 0A6...
Page 25
Manual de instrucciones 中 文 para un desimantador 版 N.º artículo 18000-15...
Page 26
Este accesorio de laboratorio es perfecto para desimantar fórceps, destornilladores y otros instrumentos y piezas de microcirugía. También puede imantar herramientas, como fórceps, lo cual puede resultar útil al trabajar con pequeños tornillos que puedan desaparecer al caerse. Este imantador tiene una relación potencia/peso alta y se aloja en una carcasa de plástico irrompible.
Page 27
I CARACTERÍSTICAS DEL PRODUCTO: Profundidad de 2.25 pulgadas Altura de 3.5 pulgadas Anchura de 4.8 pulgadas Operación Longitud del Patas de goma de un solo cable 8 pies para estabilizar botón la unidad finescience.com...
Page 28
PARA DESIMANTAR: 1. Sujete el objeto a desimantar en el centro del interior de la abertura de la carcasa. Asegúrese de que la pieza no roce la carcasa. 2. Mantenga pulsado el botón y retire el objeto lentamente en línea recta desde la abertura de la carcasa aproximadamente tres pulgadas, manteniendo el objeto alineado con el centro de la abertura de la carcasa.
Page 29
PARA IMANTAR: 1. Posicione el objeto a imantar en el interior y rozando los laterales de la abertura de la carcasa. 2. Mantenga pulsado el botón durante cuatro o cinco segundos y, después, suéltelo. 3. Ahora, el objeto debería estar imantado. Repita el procedimiento según sea necesario.
CICLO DE TRABAJO: • Esta unidad tiene una intensidad de campo superior debido al amperaje relativamente alto que absorbe. Esto conlleva un calentamiento bastante rápido de la bobina del campo. Se recomienda que cada ciclo de trabajo individual se limite de la siguiente manera: 5 segundos encendido y 3 minutos apagado, o bien tres ciclos de 5 segundos y, después, 10 minutos apagado.
Page 31
I INFORMACIÓN DE CONTACTO: Fine Science Tools (USA) Inc. 4000 East 3rd Avenue, Suite 100 Foster City, CA 94404-4824 EE. UU. Teléfono: +1 800-521-2109 / +1 650-349-1636 Fax: +1 800-523-2109/+1 650-349-3729 Correo electrónico: info@finescience.com Web: finescience.com Fine Science Tools (CAN) Inc. 410-197 Forester Street North Vancouver, British Columbia Canadá...
Page 33
Manuale d‘istruzioni 中 文 per lo smagnetizzatore 版 N. dispositivo 18000-15...
Page 34
Questo accessorio da laboratorio è perfetto per smagnetizzare pinze, cacciaviti, così come altri strumenti e componenti per la microchirurgia. Il dispositivo può inoltre magnetizzare gli strumenti, come le pinze, utile quando si lavora con piccole viti che si possono perdere se cadono. Questo magnetizzatore ha un rapporto potenza/massa molto elevato ed è...
Page 35
I CARATTERISTICHE DEL PRODOTTO: Profondità 2,25 pollici Altezza 3,5 pollici Larghezza 4,8 pollici Un pulsante Cavo lungo Piedini in gomma di accensione 8 piedi per stabilizzare l‘unità finescience.com...
Page 36
PER SMAGNETIZZARE: 1. Tenere l‘oggetto da smagnetizzare al centro dell‘apertura dell‘alloggiamento. Fare attenzione a che il componente non tocchi la custodia. 2. Tenere premuto il pulsante e ritirare lentamente l‘oggetto in linea retta dall‘apertura della custodia per circa tre pollici, mantenendo l‘oggetto in linea con il centro dell‘apertura della custodia, quindi rilasciare il pulsante.
Page 37
MAGNETIZZARE: 1. Posizionare l‘oggetto da magnetizzare all‘interno e toccare i lati dell‘apertura dell‘alloggiamento. 2. Tenere premuto il pulsante per quattro o cinque secondi e poi rilasciare il pulsante. 3. L‘oggetto dovrebbe ora essere magnetizzato. Ripetere la procedura se necessario. finescience.com...
Page 38
CICLO DI LAVORO: • Questa unità ha un‘intensità di campo molto elevata per via dell‘amperaggio relativamente alto che assorbe, il che determina un riscaldamento piuttosto rapido della bobina del campo magnetico. Si raccomanda di limitare ogni singolo ciclo di lavoro come segue: 5 secondi di accensione e 3 minuti di spegnimento, o tre cicli da 5 secondi di accensione e 10 minuti di spegnimento.
Page 39
I INFORMAZIONI DI CONTATTO: Fine Science Tools (USA) Inc. 4000 East 3rd Avenue, Suite 100 Foster City, CA 94404-4824 Telefono: +1 800-521-2109 / +1 650-349-1636 Fax: +1 800-523-2109/+1 650-349-3729 E-Mail: info@finescience.com Web: finescience.com Fine Science Tools (CAN) Inc. 410-197 Forester Street Vancouver del Nord, Columbia Britannica Canada V7H 0A6 Telefono:...
Page 41
Manual de instruções 中 文 do desmagnetizador 版 Ref.ª 18000-15...
Page 42
Este acessório laboratorial é ideal para desmagnetizar fórceps, chaves de fendas e outros instrumentos e peças microcirúr- gicos. Também consegue magnetizar ferramentas, tais como fórceps, o que pode ser útil quando se trabalha com parafusos pequenos que podem desaparecer quando caem ao chão. Este magnetizador possui uma elevada razão potência/peso e encontra-se revestido por um invólucro de plástico inquebrável.
CARACTERÍSTICAS DO PRODUTO: 5,72 cm de profundidade 8,89 cm de altura 12,19 cm de largura Operação com Cabo de Apoios de borracha um botão de alimentação para estabilizar o pressão de 2,44 m produto finescience.com...
Page 44
PARA DESMAGNETIZAR: 1. Segure no artigo a desmagnetizar dentro do centro da abertura do invólucro. Certifique-se de que a peça não toca no invólucro. 2. Prima sem soltar o botão e retire lentamente o artigo em linha reta da abertura do invólucro (faça com que ele percorra cerca de 8 cm).
Page 45
PARA MAGNETIZAR: 1. Coloque o artigo a magnetizar dentro da abertura do invólucro de modo a tocar nos lados da mesma. 2. Prima sem soltar o botão durante quatro ou cinco segundos e, em seguida, solte o botão. 3. O artigo deverá estar agora magnetizado. Repita o procedimento conforme necessário finescience.com...
Page 46
CICLO DE TRABALHO: • Este produto possui uma intensidade de campo superior devido à amperagem relativamente elevada que extrai. Isto faz com que a bobina de campo aqueça razoavelmente rápido. Recomenda-se limitar um único ciclo de trabalho da seguinte forma: cinco segundos ligado e três minutos desligado ou três ciclos de cinco segundos ligado e, em seguida, 10 minutos desligado.
INFORMAÇÕES DE CONTACTO: Fine Science Tools (USA) Inc. 4000 East 3rd Avenue, Suite 100 Foster City, CA 94404-4824 Telefone: +1 800-521-2109 / +1 650-349-1636 Fax: +1 800-523-2109/+1 650-349-3729 E-mail: info@finescience.com Site: finescience.com Fine Science Tools (CAN) Inc. 410-197 Forester Street North Vancouver, British Columbia Canadá...
Page 55
联络信息: Fine Science Tools (USA) Inc. 4000 East 3rd Avenue, Suite 100 Foster City, CA 94404-4824 +1 800-521-2109 / +1 650-349-1636 电话: +1 800-523-2109/+1 650-349-3729 传真: 电子邮箱: info@finescience.com finescience.com 网站: Fine Science Tools (CAN) Inc. 410-197 Forester Street North Vancouver, British Columbia Canada V7H 0A6 +1 800-665-5355 / +1 604-980-2481 电话:...
Page 63
お問い合わせ先 : Fine Science Tools (USA) Inc. 4000 East 3rd Avenue, Suite 100 Foster City, CA 94404-4824 アメリカ合衆国 電話 : +1 800-521-2109 / +1 650-349-1636 ファックス : +1 800-523-2109/+1 650-349-3729 メール : info@finescience.com ウェブサイ ト : finescience.com Fine Science Tools (CAN) Inc. 410-197 Forester Street North Vancouver, British Columbia Canada V7H 0A6...
Page 66
이 실험실용 장치는 포셉, 스크류 드라이버와 다른 미세 수술 기 구 및 그 부품의 자성을 완벽히 제거합니다. 기구의 자기화 또한 가능합니다. 이는 떨어뜨리면 잊어버리기 쉬운 작은 스크류를 다 루는 포셉과 같은 기구를 사용할 때 편리합니다. 이 자화기는 높 은 중량 대비 출력을 가지고 있으며, 깨지지 않는 플라스틱 몸체 를...
Page 67
제품 특징: 2.25 인치 깊이 3.5 인치 높이 4.8 인치 넓이 원 푸시 버튼 8피트 길이 장치의 안정적인 작동 전선 고정을 위한 고무 발 finescience.com...
Page 68
탈자기화할 경우: 1. 탈자기화할 기구를 장치의 가운데 개구부에 위치하도록 듭 니다. 기구가 장치의 몸체에 닿지 않도록 주의를 기울여 주세요. 2. 버튼을 누른 상태에서 장치를 개구부의 중심과 일직선이 되도록 유지하면서 개구부에서 약 3인치 정도 천천히 빼낸 다음 버튼을 놓습니다. 3. 기구는 이제 탈자기화되었습니다. 필요한 만큼 작업을 반 복합니다.
Page 69
자기화할 경우: 자기화할 기구를 장치의 가운데 개구부에 위치하도록 듭니다. 버튼을 누른 채로 4-5초 유지한 뒤, 버튼을 놓습니다. 기구는 이제 자기화되었습니다. 필요한 만큼 작업을 반복합 니다. finescience.com...
Page 70
사용 주기: • 이 장치는 상대적으로 높은 암페어로 인해 우수한 전계 강 도를 가지고 있습니다. 그 결과 계자 코일이 상당히 빠르게 가열 됩니다. 아래와 같이 장치의 단일 사용 주기를 제한하는 것을 권 장합니다. 5초 작동 후 3분 휴식, 또는 5초 작동 3회 이후 10분 휴식. • 이 장치에는 과열 방지 장치가 배선되어 있습니다. 상기의 사용주기를 준수하지 않을 경우, 온도조절기가 작동되어 장치가 충분히 식기 전까지 작동되지 않습니다. 이 장치는 연속적이 아닌 간헐적으로 사용할 목적으로 설계되었습니다. 살균: • GAD, EtO 살균만 사용. • 증기 멸균하지 마십시오.
Page 71
연락처: Fine Science Tools (USA) Inc. 4000 East 3rd Avenue, Suite 100 Foster City, CA 94404-4824 미국 +1 800-521-2109 / +1 650-349-1636 전화번호: +1 800-523-2109/+1 650-349-3729 팩스: info@finescience.com 이메일: finescience.com 사이트: Fine Science Tools (CAN) Inc. 410-197 Forester Street North Vancouver, British Columbia 캐나다...
Need help?
Do you have a question about the 18000-15 and is the answer not in the manual?
Questions and answers