    TABLE OF CONTENTS: FEATURES DESCRIPTION TECHNICAL SPECIFICATION SUMMARY SHEET OPERATING AND COOLANT CONDITIONS 3.2.1 OPERATING CONDITIONS 3.2.2 COOLANT CONNECTIONS 3.2.3 COOLANT QUALITY ELECTRICAL CONNECTION 3.3.1 POWER INPUT 3.3.2 MAIN CABLE AND LEADS 3.3.3 COLD HEAD CONTROLS 3.3.4 AUTO RESTART FUNCTION INSTALATION UNPACKING AND INSPECTION MOUNTING...
  • Page 2: Features

    MAIN FEATURES • Absorber can be replaced from the front of the unit, permitting convenient rack or cabinet installation. • Both high and low side pressure gages. • Electrical box is a field replaceable unit. • High and low voltage units available for use at both 50 Hz and 60 Hz.
  • Page 3: Description

    DESCRIPTION Compressed helium is used as a refrigerant when trying to achieve cryogenic temperatures (as low as 4 Kelvin). The high-pressure helium is delivered from the compressor to a cold head through the supply line (300-350 psi). The helium is expanded in the cold head to produce a temperature drop. The cold head uses a motor and a piston like “displacer”...
  • Page 4 Flow diagram of the compressor system...
  • Page 5: Technical Specification

    TECHNICAL SPECIFICATION 21.0 17.4 18.0 3.1 SUMMARY SHEET COMPRESSOR SPECIFICATION UNITS M600-HV M600-LV VOLTAGE REQUIREMENTS (±10%) 50HZ-3 PHASE V 60HZ-3 PHASE V POWER REQUIREMENTS 50HZ-3 PHASE KW 60HZ-3 PHASE KW OPERATING CURRENT WITH WARM COLD HEAD 50HZ A 60HZ A...
  • Page 6: Operating And Coolant Conditions

    RETURN HELIUM PRESSURE 50HZ PSI (bar) 60HZ PSI (bar) SUPPLY HELIUM PRESSURE 50HZ PSI (bar) 60HZ PSI (bar) COOLANT DATA FLOW RATE (MIN) GPM MIN. INLET TEMPERATURE °F(C) 40(5) 40(5) MAX. INLET TEMPERATURE °F(C) 85(30) 85(30) WEIGHT Lb(kg) 230(105) 230(105) 3.2 OPERATING AND COOLANT CONDITIONS 3.2.1 OPERATING CONDITIONS: When the compressor is operating, the ambient temperature must...
  • Page 7: Electrical Connection

    Using Helium hose manifolds and drive cable Splitter Boxes to meet customer requirements. 3.4.2 CRYOPUMP CONFIGURATIONS The M600 is capable of operating cryopumps in the following configurations. 1. Up to Three (3) CP-8’s. 2. Two (2) CP-10’s, or one CP-10 & one CP-8...
  • Page 8: Instalation

    240psi±10%. The unit comes with a removable castor frame. We have the option to install feet, castors or rails, depending on the customer requirement. If damage is detected contact the carrier and Austin Scientific as soon as possible. MOUNTING 4.2.1 MAX OPERATING ANGLE...
  • Page 9 Crossing the connection on the cold head will cause damage to the internals of the cold head. With the appropriate cable supplied from Austin Scientific, complete the connections form the compressor electronic box to the electrical connection on the cold head. This will supply...
  • Page 10: Operation

    OPERATION SWITCHING ON Turning the compressor on will automatically start the compressor and cold head. It is not recommended to run a compressor without all the proper connections verified. NORMAL OPERATION The helium used for this compressor must be ultra high pure quality (99.9999% pure) any impurities can cause problems inside the cold head that the compressor is controlling.
  • Page 11: Maintanance And Service

    The service interval of the absorber of the M600 is 20,000 hours (27.4 months). The M600 absorber has been placed at the front of the unit, behind a removable cover, to facilitate replacement. Absorber replacement should take about 15 minutes. This is ideal for rack and rail mounted compressor units.
  • Page 12 RETURNING EQUIPMENT Before returning any equipment, please contact Austin Scientific to receive special instructions and to obtain a Return Good Authorization (RGA) number. Austin Scientific 4114 Todd Lane P.O. BOX 18863 Austin, TX 78760 (512) 441-6893 FAX (512) 443-6665 Austin Scientific...