Decentralised ventilation system with heat recovery (11 pages)
Summary of Contents for Partel LUNOS AB 30
Page 1
Installation Manual Exhaust air fans Type AB 30/60 and Type RA 15-60 - Please pass on to user -...
Page 2
Content 9/R 160-500 036765 9/R 160-700 039891 AB 30/60 039995 RA 15-60 039996 Hinweise Notes...
Page 3
9/R 160-500 036765 9/R 160-700 039891 Ø 162 mm 3 mm Ø 162 mm min. 100 mm 200 - 390 mm LUNOtherm - 55 mm LUNOtherm-S...
Page 4
AB 30/60 039995 1 (9/FIB-3R 037205) 2 (9/SW 039850) Power supply 100-240 V AC 50/60 Hz Volume flow 30 m³/h / 60 m³/h 1,6 W / 5 W Power consumption 36 dB(A) / 52 dB(A) Sound power level Sound pressure level 1 m 28 dB(A) / 44 dB(A) Sound pressure level 3 m 19 dB(A)
Page 5
N + L = 30 m³/h N + L + L1 = 60 m³/h 24h 30 m³/h 30 m³/h 60 m³/h 60 m³/h 130 mm 1/WE 180 (039852) 100 mm 9/IBE (039851) X mm AB 30/60 039995 9/SW 039850...
Page 6
RA 15-60 039996 1 (9/FIB-3R 037205) 2 (9/SD-S 039919) 12 V DC SELV, max. 12,6 V Device voltage Flow rate 15 - 60 m³/h Power consumption 0,6 W - 7,2 W 24 - 45 dB(A) Sound power level Sound pressure level 1 m 16 - 37 dB(A) Sound pressure level 3 m 6 - 27 dB(A)
Page 7
J-Y(St)Y(2x2x0,8) min. 0,5 mm², max. 1,5 mm² 5/UNI-FT 040089 RA 15-60 max. 45 m³/h RA 15-60 RA 15-60 max. 60 m³/h #1/2 5/GS (optional) rot / red blau / blue S1 lila / purple 0-10 V Eingang / Input - TAC, 5/GS (optional) Gerät / Device 5/SC-FT 040113 e²...
Page 8
About this manual Before installing, read these instructions carefully and completely! You must observe the general safety instructions and the warning symbols with notes in the text. These instructions are to be passed on to the user after installation (tenant, owner, property ma- nagement etc.).
Page 9
Filter replacement Check the filter (1) every 3 months for contamination. Clean or replace, if required. Never operate the unit without a filter. Remove design screen, take filter out, insert new or cleaned filter (filters can be cleaned e.g. in a dishwasher), put design screen on.