This electrode must only be used on this model of chlorine generating device. READ THE LABEL AND REFER TO OWNERS MANUAL OF THE Pool Pilot® Professional, Model PROB28, BEFORE USING AquaCal AutoPilot, Inc. 2737 24th St. North St. Petersburg, Florida, U.S.A, 33713...
TABLE OF CONTENTS INTRODUCTION… ................... 4 WARRANTY INFORMATION… ..............5 SAFETY INFORMATION… ..............6-7 PREPARING YOUR WATER BEFORE INSTALLATION… ....8-9 SALT CHART FOR CORRECT MAINTENANCE… ........ 10 TOOLS AND PARTS REQUIRED FOR INSTALLATION…....11 PLUMBING YOUR SYSTEM .............. 12-13 ELECTRICAL SPECIFICATIONS .............
Page 4
It is an offence under the Pest Control Products Act, to use this product in a way that is inconsistent with the directions on the label. AquaCal AutoPilot, Inc. 2737 24th St. North St Petersburg, FL, USA 33713...
READ THE LABEL AND REFER TO OWNERS MANUAL OF THE Pool Pilot Professional, Model ® PROB28, BEFORE USING THE POOL AquaCal AutoPilot, Inc. 2737 24th St. North St. Petersburg, Florida, U.S.A, 33713 1-727-823-5642 INTRODUCTION AquaCal AutoPilot, Inc.
(Year 1 is warranted fully, thereafter pro- rated warranty applies, applicable over the full 2 year period) • AquaCal AutoPilot, Inc. advises that titanium electrodes will have to be replaced every 15,000 hours of operating time. Under no circumstances shall the replacement titanium electrodes exceed the original 15,000 hour warranty.
SAFETY INFORMATION PLEASE READ THE FOLLOWING SAFETY INFORMATION CAREFULLY! WARNING! • Only a certified technician may install and service your Pool Pilot® Professional system. • Modifying your Pool Pilot® Professional system in anyway may cause bodily injury and will void your warranty. •...
Page 8
• When replacing the cell, only use replacement cells having a label that clearly states that it is a replacement cell for the chlorine generating device Pool Pilot® Professional Chlorination System, Model PROB28, REGISTRATION NUMBER XXXXX, PEST CONTROL PRODUCTS ACT. •...
PREPARING YOUR WATER BEFORE INSTALLATION Pool Pilot® Professional saline chlorination systems operate by utilizing the sodium chloride that has been added to the pool water, to produce sodium hypochlorite (liquid chlorine), through the process of electrolysis. In order for your Pool Pilot®...
Page 10
Use standard test kits to check water chemistry, and use either a conductivity tester or salt test strip to check saline levels. (Note that most conductivity testers require frequent calibration to ensure accurate readings, failure to calibrate the equipment will result in inaccurate readings.) How to Calculate volume of a pool For a rectangular shaped pool...
The following is a chart to determine the amount of salt required to raise a pool or spa to 5000 ppm SALT CHART FOR CORRECT MAINTENANCE ppm Salt Levels Number of KG of Salt to Be Added ppm Salt Pool and or sp Volume (litres) 1,000 100,000 200,000...
TOOLS AND PARTS REQUIRED FOR INSTALLATION Your Pool Pilot® Professional system will include an installation kit comprising of the following items: Description Strainer clear bowl with 20 mesh PVC ball valve Sch. 40 PVC male adaptor Sch. 40 PVC nipple SCH 80 PVC bushing Threaded PVC union S EPDM w/o O-ring Sch.
PLUMBING YOUR SYSTEM Your Pool Pilot® Professional system can be plumbed using two different methods. Both will work fine, however, the following must be taken into account before making the decision of what method to use. 1. Your Pool Pilot® Professional system requires a minimum of 75 Lpm of flow through the cell to produce the rated amount of chlorine.
Page 14
PRESSURE-DROP PLUMBING METHOD [1] Pool Pilot® Professional power supply Pool Pilot® Professional cell NOTES: THE RECTIFIER COOLING LINES MUST BE CONNECTED FROM THE SUCTION SIDE OF THE PUMP AND AFTER THE FILTER. ALWAYS USE FILTERED WATER. IF THERE IS A CONTROLLER PRESENT, THE OUTLET LINE THAT FEEDS THE CONTROLLER PROBES COULD BE CONNECTED TO THE RECTIFIER.
ELECTRICAL SPECIFICATIONS Each Pool Pilot® Professional model has very specific wiring requirements based on its line voltage and amperage draw. • Model CHLOR-25 operates at 208 – 240v requiring advanced wiring, which should only be done by a qualified electrician. 208 – 240v power needs to be run from your main breaker panel to a safety switch, then into Pool Pilot®...
STARTING THE SYSTEM Once your Pool Pilot® Professional system has been successfully wired and plumbed, it is ready for use. • Make sure that the valves to and from the cell are in the open position. • Make sure that you have water flowing through the water-cooled heat sink in box 3.
GENERAL OPERATION Your Pool Pilot® Professional system operates when power is activated by the main pumps, and from your ORP controller, and will continue to operate for as long as power is applied from those two sources. • The system has an output range of 5-100% of the rated chlorine production, and can be adjusted by turning the black knob of the side of box 1 in a clockwise or anti-clockwise motion.
By ensuring that salt is always at the correct level, and plates are cleaned regularly, you will increase their “life”, thus saving you money… AquaCal AutoPilot, Inc. offers a wide range of other products that can help you maintain salt levels in your pool, including conductivity controllers and saturated...