Advertisement

HC2-E1000 SERIES
Thank you for using E1000 series, economical AC motor speed
controller made by TECORP ELECTRONIC CO., LTD
In order to make use of the functions full on the AC motor speed
controller and ensure safety of user, please read this instruction carefully
before installing, running, maintaining and checking AC motor speed
controller.
This instruction divides safety cautions into Danger and Warning,
please pay special attention to the symbols "
their related content.
The symbol "
cause death or serious injury to personnel.
The symbol "
personnel injury or AC motor speed controller and mechanical system fault,
as determined by different situations, the caution affairs may lead to
serious consequence.
The figures in this instruction are for convenience with descriptions;
they may have slight differences compared to the products, and the
products update can also cause slight differences between the figures and
products, the actual sizes are subject to actual products.
Please notice that this operational instruction shall be delivered to the
end user, and be kept appropriately for further use of inspecting and
maintaining.
If you have questions, please contact us or our agents in time, you
will always receive our best attention.
- 0 -
" indicates incorrect operation, which can
" indicates incorrect operation, which can cause
" and "
" and

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the HC2-E1000 Series and is the answer not in the manual?

Questions and answers

Summary of Contents for TECORP ELECTRONIC HC2-E1000 Series

  • Page 1 HC2-E1000 SERIES Thank you for using E1000 series, economical AC motor speed controller made by TECORP ELECTRONIC CO., LTD In order to make use of the functions full on the AC motor speed controller and ensure safety of user, please read this instruction carefully before installing, running, maintaining and checking AC motor speed controller.
  • Page 2: Table Of Contents

    HC2-E1000 SERIES Contents Chapter 1 Safety Cautions ------------------------------------------------- 2 1-1 Confirmation on Receiving ----------------------------------- 2 1-2 Moving and Installation ---------------------------------------- 2 1-3 Wiring and Junction -------------------------------------------- 4 1-4 Power on and Commissioning -------------------------------- 5 1-5 Check and Maintenance --------------------------------------- 6...
  • Page 3: Chapter 1 Safety Cautions

    HC2-E1000 SERIES Chapter 1 Safety Cautions 1-1 Confirmation on Receiving Warning All the products have gone by strictly checking and testing before delivery, but considering transportation, please verify: Whether AC motor speed controller is distorted or damaged during transportation, do not install broken AC motor speed controller, and it may cause personnel injury, please inform our agent in time.
  • Page 4 Ambient temperature: -10℃-40 ℃ 〈non-freezing〉. Ambient humidity: max. relative humidity 〈non-condensing〉 Ambient environment: indoors, 〈 no corrosive gas, combustible gas, oil mist and dust. Please keep off sunlight〉. Altitude: lower than 1000m Vibration: max. 0.5G Please make sure that the mounted substance can load with AC motor speed controller’s weight and prevent it from falling, and make sure that the installation site is safe and reliable.
  • Page 5: Wiring And Junction

    HC2-E1000 SERIES 1-3 Wiring and Junction Warning Please do not damage the wires. Let the wires bear weight or be clamped may damage the wires and cause an electric shock. Do not install the phase-shifting capacitor, surge absorber or noise filter in output terminal of AC motor speed controller, otherwise may cause AC motor speed controller fault.
  • Page 6: Power On And Commissioning

    the internal fault of AC motor speed controller. Please do not test AC motor speed controller on pressure resistance. Otherwise it may cause the internal fault of AC motor speed controller. Please install accessories such as brake units, brake resistors in accordance with the user’s instruction;...
  • Page 7: Check And Maintenance

    HC2-E1000 SERIES controller casually during running. Please do not touch the heat sink and brake resistor, otherwise you may get burned. Do not use wet hands to touch bottom plate and to operate switches and keys. Otherwise you may get an electric shock or injury.
  • Page 8: Exception Processing

    1-6 Exception Processing Danger When the protection in AC motor speed controller is on, please follow the fault display of AC motor speed controller to find out causes and eliminate the fault, then reset and restart AC motor speed controller. If the fault is not eliminated. Resetting and restarting AC motor speed controller can cause AC motor speed controller s or machine fault.
  • Page 9: Chapter 2 Product Introduction

    HC2-E1000 SERIES Chapter 2 Product Introduction 2-1 Unpacking Inspection In unpacking, please confirm the following: Check whether the model type of AC motor speed controller is in accordance with your order. Check whether AC motor speed controller is damaged and related accessories are completed.
  • Page 10: Product Specifications

    2-3 Product Specifications Items Description Rated Voltage, Single/Three-phase 220V- 50/60Hz Input Frequency Three-phase 380V-50/60Hz Allowable Voltage 170~240V, 330~440V Allowable Voltage 170~240V, 330~440V Output Frequency 0.10~400.0Hz Control Mode V/F control Five-digit LED display, Indicator display; Display setup frequency, Output frequency, Display Output current, DC voltage, Module temperature, Running state, and fault Digital setting: 0.01 Hz.
  • Page 11: Product Models

    HC2-E1000 SERIES 2-4 Product Models Output Overload Applicable Power Capacity Model current capacity motor Output (60s) (A) (KW) Single/Three-phase 220V - 50/60Hz HC200D4E24F 3.75 HC200D7E24F 0.75 0.75 10.5 HC201D5E24F HC202D2E24F 16.5 Three-phase 380V - 50/60Hz 0.75 4.05 0.75 HC200D7E48F HC201D5E48F...
  • Page 12: Chapter 3 Wiring And Operation

    Chapter 3 Wiring and Operation 3-1 Wiring Diagram 3-2 Display Panel The display panel of Series E1000 consists of LED tubes, LED indicators buttons and digital elements. The outline and functions as the following: - 11 -...
  • Page 13: Parameter Setting

    HC2-E1000 SERIES Display: setting frequency, running frequency, electronic current, and parameter value and alarm code. Status lamp: display the present status Function option / Save button Programming button Switch button Down Jog button Running button Stop button Frequency setting button...
  • Page 14: Chapter 4 Table Of Functional Parameters

    Chapter 4 Table of Functional Parameters F0 group - Basic parameters Code Parameter Settings Default 0: Digital F000 Frequency setup 1: Keyboard POT 2: Analog F001 Main frequency 0.0 ~ 400.0Hz 50Hz 0: Keyboard F002 Operation setup 1: IO terminal Maximum running 50Hz F004...
  • Page 15 HC2-E1000 SERIES Code Parameter Settings Default F120 Jog frequency 0.0 ~ 10.0Hz 0.2Hz *2Hz F121 Jog acceleration time 0.01s ~ 60.00s F2 group – Input / Output parameters Code Parameter Settings Default 0: General F200 Control mode 1: Knitting 1: Speed terminal 1...
  • Page 16 F4 group– Display parameters Code Parameter Default F400 Output frequency F401 Setup frequency F403 Output voltage F404 Voltage of DC bus F405 Input terminal signal F409 Fault record 1 F410 Fault record 2 F411 Fault record 3 F412 Fault record 4 Example: Multi-speed Parameter F203 = 3...
  • Page 17: Chapter 5 Fault Alarm And Solutions

    HC2-E1000 SERIES Chapter 5 Fault Alarm and Solution Error Alarm Possible Reason Solution Code 1) Too short acceleration time 1) Extend acceleration time 2) Disarrangement of V/F curve 2) Correct V/F curve Over 3) Restart in running the motor 3) Restart after running the...
  • Page 18 1) Sudden over current 1) Refer to error code OC Failed to the 2) Short circuit of the output or 2) Check the connection Capacity grounding and the wire Module 3) Bad aeration or failed the fan 3) Improve aeration 4)...