RP-2027 Series Room Sensor User Manuel
1.1

Features

RP-2027 adopts digital control technology with large LCD display. It shows the
following items: working status (Cool
speed of two fans, room temperature, set-point etc. There are following keys on
the panel: On/Off "
", Mode "
"" and "".
1.2

Applications

This product can be used all USC-HRV Series HVAC controllers, USC-FCU Series
Fan Coil Unit controllers, USC-HP Series Heat Pump controllers, USC-VAV Series
Variable Air Volume controllers, USC-TH Series Trench Heater controllers.
2

Technical Specification

Power Supply
Temperature Input
Communication
Operation
General
3

Display and Operations

3.1

Overview

Setpoint
Room Tmp
Air Quality
Days
Supp. Air Tmp
Out. Air Tmp
Exh. Air Tmp
Ent. Wat. Tmp
Leav. Wat. Tmp
Doc: 00-12-01, V1.3, 20170201
®
Copyright © Smallart
www.smallart.com.tr
, Heat
, Ventilation
", Select fan speed " ", set-point temperature
Operation Voltage
Power Consumption
Wirings
Type
Display Range
Accuracy
Communication Type
Protocol
Cabling
Temperature
Humidity
Setpoint Range
Dimensions
Hole Pitch
Protection Class
Auto
Cooling
Heating
Supply Air Fan Speed
Auto-5-4-3-2-1
Tmp Value
or Auto
), the
12VDC
< 1W
Screw-in terminals, each terminal
capable of accepting 2 × 1.5 mm
or 1 × 2.5 mm
NTC
0~50°C
± 1°C
RS485, Peer to Peer
Modbus RTU
Shielded Twisted Pair (STP),
RS485 Data Communication Cable
2 X 2 X 0,34...0,75mm
0~45°C
5~90%RH (non-condensing)
5℃~35°C
86 × 86 × 22.2 mm (W × H × D)
60 mm (Standard)
IP30
Ventilation
Heaters
Exhaust Air Fan Speed
1-2-3-4-5-Auto
RP-2027
ROOM CONTROL PANEL
2
2
wires
2
Clock
Fahrenheit
Celcius
Alarm
Keylock
Page 1 / 4

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the RP-2027 Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Smallart RP-2027 Series

  • Page 1 RP-2027 ROOM CONTROL PANEL RP-2027 Series Room Sensor User Manuel Features RP-2027 adopts digital control technology with large LCD display. It shows the following items: working status (Cool , Heat , Ventilation or Auto ), the speed of two fans, room temperature, set-point etc. There are following keys on the panel: On/Off “...
  • Page 2 Press “ ” to raise the parameter’s value, press “ ” to reduce the parameter’s value. 5.1.2 Technician Parameters The parameters which are shown as “Technician Parameters” in the table are application-specific parameters. Doc: 00-12-01, V1.3, 20170201 Page 2 / 4 ® Copyright © Smallart www.smallart.com.tr...
  • Page 3 - Specify the centers of holes to be drilled in the wall. Distance of between the centers of holes should be min. 96 mm. - Open the mounting hole to wall using a 68 mm holesaw. Doc: 00-12-01, V1.3, 20170201 Page 3 / 4 ® Copyright © Smallart www.smallart.com.tr...
  • Page 4 6.4.4 Wire and Connecting Shielded, twisted pair, RS485 Data Communication Cable must be used. (2 X 2 X 0,34…0,75mm Doc: 00-12-01, V1.3, 20170201 Page 4 / 4 ® Copyright © Smallart www.smallart.com.tr...

Table of Contents