ImageWare Bookeye 3 Setup And Assembly Manual

Glass plate

Advertisement

Quick Links

Glass Plate
Setup and Assembly Manual

Advertisement

Table of Contents
loading

Summary of Contents for ImageWare Bookeye 3

  • Page 1 Glass Plate Setup and Assembly Manual...
  • Page 2 File: BE3-SetupAndAssembly-GlassPlate-A.doc...
  • Page 3 ImageWare. All other trademarks are the property of their respective owners. ImageWare reserves the right at any time without notice to change said product, product specification and documentation. For the most recent version always check the web site www.imageaccess.de...
  • Page 4 Version History Version Published in Content/Changes/Supplements April 2006 First version. Description of assembling steps. Page 4 Glass Plate Setup and Assembly Manual...
  • Page 5: Table Of Contents

    Table of Content A Hardware Setup ---------------------------------------------------------------- 7 Content on Delivery ..................7 Preparing Steps ..................8 Assembling the Gas Spring to the Lamp ..........11 Assembling the Glass Plate..............12 B Software Setup --------------------------------------------------------------- 17 Install the Option..................17 B.1.1 Install the Option Key B.1.2 Mount the Glass Plate Mandatory Optical Adjustments ..............21...
  • Page 6 Table of Pictures Picture 1: Assembly material of the glass plate option............7 Picture 2: Glass Plate......................7 Picture 3: Removing the book cradle plates................ 8 Picture 4: Removing the screw.................... 8 Picture 5: Screws at the rear panel and at the bottom of the body element......9 Picture 6: Moving the cover....................
  • Page 7: A Hardware Setup

    Hardware Setup Content on Delivery Picture 1: Assembly material of the glass plate option The optional glass plate is delivered with the following material: — 2x Mounting brackets — 4x Plastic washers — 2x T-slot nuts — 2x Hexagon socket head screws —...
  • Page 8: Preparing Steps

    Preparation Steps ® To assemble the glass plate to the Bookeye 3 the following steps have to be performed: 1. Remove the book cradles. Pull the book cradle plates upwards from the driving elements. Picture 3: Removing the book cradle plates 2.
  • Page 9: Picture 5: Screws At The Rear Panel And At The Bottom Of The Body Element

    For easy access to the screws at the bottom, place the device on the edge of the table. 3. Remove eight hexagonal socket head screws M4x10 on the rear panel. 4. Remove four hexagonal socket head screws M4x10 on the left and four on the right side of the bottom.
  • Page 10: Picture 7: Lamp Cable Connector

    6. Disconnect the lamp cable from its connector. The lamp cable connector is found inside the main body at the bottom of the lamp holder bracket. Picture 7: Lamp cable connector 7. Loosen and unscrew the two hexagonal socket head screws M8x12 on the rear panel which hold each lamp.
  • Page 11: Assembling The Gas Spring To The Lamp

    Assembling the Gas Spring to the Lamp ® Before assembling the glass plate to the Bookeye 3 scanner, a special gas spring has to be assembled to each lamp. Place the lamp on a desk a shown in the picture below. Picture 9: Assembling gas spring to lamp Slide in the gas spring the direction of the arrow from the bottom side.
  • Page 12: Assembling The Glass Plate

    Assembling the Glass Plate ® Before assembling the glass plate to the Bookeye 3, it is necessary that the scanner is fully set up and ready to use. That means — the lamps are connected to the lamp connectors, — the lamps are fastened to the rear panel, —...
  • Page 13: Picture 11: Glass Plate On Book Cradle Plates

    Place the glass plate on the book cradle plates as shown in Picture 11. Picture 11: Glass plate on book cradle plates Check the position of the T-slot nuts in the notch of the left and right lamp beam. The position of the T-slot nuts must correspond with the borehole in the bearing.
  • Page 14: Picture 13: Holder Assembled To Lamp

    Fasten each holder with the hexagonal socket head screw. Use an Allen wrench to tighten the screws. Picture 13: Holder assembled to lamp The mounting brackets on the left and right side have a ball-shaped head on the upper side. This ball-shaped head is used to connect the glass plate to the gas spring. Picture 14: Detail view of mounting bracket Page 14 Glass Plate Setup and Assembly Manual...
  • Page 15: Picture 15: Gas Spring Assembled To Mounting Bracket

    Note: Because of the weight of the glass plate, the following assembling steps should be done by two persons. Lift up the glass plate to a position where it matches with the gas spring end. Hold it in this position. The second person connects the gas springs to the ball-shaped heads by pressings the parts together until they click in.
  • Page 16: Picture 17: Setting The Brake Power

    Each gas spring has a brake built into it, which is user adjustable. This brake can be used to stop the glass plate from moving in any position. It has to be noted, that fastening the brakes need more energy from the operator to lift the glass plate. Picture 17: Setting the brake power Adjusting the brake is done in just a few steps.
  • Page 17: B Software Setup

    Software Setup Install the Software Option The Bookeye must be configured so that the existence of the optional glass plate is known to the device. Since the glass plate does not connect to the device electrically, some procedures need to be performed to install it completely. B.1.1 Install the Option Key The glass plate option is enabled using a software key, which is part of the shipment.
  • Page 18: Picture 20: "Install Option" Screen

    Locate the section Updates and Uploads and go to Install Options . All option keys displayed in green are valid and installed. A new key must be entered completely, without blanks or spaces followed by pressing the Apply button. If the key displayed does not turn green, the key is invalid or does not belong to this specific scanner or option.
  • Page 19: Mount The Glass Plate

    B.1.2 Mount the Glass Plate If the glass plate option is activated, a new control Glass Plate Mounting Status will appear in the user setup menu. An incorrect mounting status could result in error messages or malfunction of the scanner. Whenever the glass plate is temporarily removed, it must be reconfigured for the system through this function.
  • Page 20: Picture 23: "User Settings" Screen

    In the field S2N Base Settings Click the button User and the following screen will be displayed. Picture 23: “User Settings” screen Change the status to “Mounted” to perform the following adjustment procedures. Whenever the glass plate option is permanently or temporarily removed, check the appropriate button again.
  • Page 21: Mandatory Optical Adjustments

    Mandatory Optical Adjustments When the device is set up for the first time, moved to a different location, cleaned, serviced or after a software update; some adjustments have to be performed to guarantee maximum scanning quality and accuracy. Access to these functions is possible only through the login level “Poweruser”, default password “Poweruser”.
  • Page 22: Picture 24: "Poweruser Main Menu" Screen

    Locate the section Adjustment & Support and go to Adjustments . Picture 24: “Poweruser main menu” screen Start in the section Focus & Scan Areas Adjustments. Select the appropriate menu items as described in the following paragraphs. Picture 25: “Adjustment & Support“ screen Page 22 Glass Plate Setup and Assembly Manual...
  • Page 23: Auto Focus

    B.2.1 Auto Focus This function automatically locates the lens position for the highest level of sharpness and best image quality. The book cradles must be in the lowest position. This value is the reference for all focus adjustments used later; for example during book fold correction, folder mode scanning or fixed focus scanning.
  • Page 24: White Balance

    B.2.2 White Balance Perform the function as follows: 1. Find the section White Balance Adjustments and click the button White Balance . 2. Place the Line Reference Target LRT-BE3-x under the glass plate as shown on the screen. The screen shows a blinking area at the LRT-BE3-x. 3.
  • Page 25: C Tests And Troubleshooting

    Tests and Troubleshooting Troubleshooting Matrix Problem Possible cause Action Image is darker than The target used for white Go to the White Balance function expected. balance is much brighter and modify the Brightness Correction than the scanning target. setting. Image is brighter than The target is much brighter Go to the White Balance function expected.
  • Page 26: D Technical Data

    Technical Data Dimensions and Weight Glass plate assembly outer dimensions 1250 x 900 x 780 mm (H x W x D) Scanner outer dimensions (lamps attached) 1250 x 1500 x 780 mm (H x W x D) Dimensions Transport Box 490 x 1055 x 945 mm (H x W x D) Glass plate assembly weight: 89 kg...
  • Page 27 Notes Glass Plate Setup and Assembly Manual Page 27...