eHealthcare H100 User Manual

Homecare multi-parameter recorder

Advertisement

Quick Links

Homecare Multi-Parameter Recorder
Product Name: Homecare Multi-parameter Recorder
Product Model: H100
Company Name: eHealthcare
Address: 250 East Gish Road San Jose, CA 95112, USA
H100
User Manual
Version:A1.4
www.ehealthcareinc.com
info@ehealthcareinc.com
250 East Gish Road, San Jose
CA, 95112 USA

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the H100 and is the answer not in the manual?

Questions and answers

Summary of Contents for eHealthcare H100

  • Page 1 250 East Gish Road, San Jose CA, 95112 USA H100 Homecare Multi-Parameter Recorder User Manual Version:A1.4 Product Name: Homecare Multi-parameter Recorder Product Model: H100 Company Name: eHealthcare Address: 250 East Gish Road San Jose, CA 95112, USA...
  • Page 2: Table Of Contents

    www.ehealthcareinc.com info@ehealthcareinc.com 250 East Gish Road, San Jose CA, 95112 USA Homecare Multi-parameter Recorder Content Content ............................- 1 - Preface ............................ - 2 - Chapter 1 Safety information ....................- 4 - 1.1 Signs in this manual ................. - 4 - 1.2 Important Notes for Safety ..............
  • Page 3: Preface

    250 East Gish Road, San Jose CA, 95112 USA Homecare Multi-parameter Recorder Preface Product Information Product Model: H100 Product Name: Homecare multi-parameter Recorder After Service Contact Information: Address: 250 East Gish Road San Jose, CA 95112, USA Email: info@ehealthcareinc.com CE mark...
  • Page 4 www.ehealthcareinc.com info@ehealthcareinc.com 250 East Gish Road, San Jose CA, 95112 USA Homecare Multi-parameter Recorder and operator safety. This manual is based on the maximum configuration and therefore some contents may not apply to your product. If you have any question, please contact us. This manual is an integral part of the product.
  • Page 5: Chapter 1 Safety Information

    www.ehealthcareinc.com info@ehealthcareinc.com 250 East Gish Road, San Jose CA, 95112 USA Homecare Multi-parameter Recorder Chapter 1 Safety information 1.1 Signs in this manual Warning: Indicates a potential hazard or unsafe practice that, if not avoided, will result in death or serious injury. Symbol Symbol Note Symbol...
  • Page 6 www.ehealthcareinc.com info@ehealthcareinc.com 250 East Gish Road, San Jose CA, 95112 USA Homecare Multi-parameter Recorder Symbol Symbol Note Symbol Symbol Note Humidity limitation Pressure limitation Symbol for the marking of electrical and electronics CE mark devices according to Directive 2002/96/EC. Warning: ◼...
  • Page 7: Important Notes For Safety

    www.ehealthcareinc.com info@ehealthcareinc.com 250 East Gish Road, San Jose CA, 95112 USA Homecare Multi-parameter Recorder ◼ Magnetic and electrical fields are capable of interfering with the proper performance of the recorder. For this reason make sure that all external devices operated in the vicinity of the recorder comply with the relevant EMC requirements.
  • Page 8 ◼ Battery The H100 pad device is equipped with a battery. The battery discharges even when the device is not in use. Store the device with a fully charged battery and take out the battery, so that the service life of the battery will not be shortened.
  • Page 9: Safe Operation Conditions

    www.ehealthcareinc.com info@ehealthcareinc.com 250 East Gish Road, San Jose CA, 95112 USA Homecare Multi-parameter Recorder Magnetic and electrical fields are capable of interfering with the proper performance of the device. For this reason, make sure that all external devices operated in the vicinity of the recorder comply with the relevant EMC requirements.
  • Page 10: Chapter 2 Product Description

    ECG cable, blood pressure cuff and SPO2 probe which for monitoring the physiological data of ECG,SPO2 and NIBP at home. It can realize data transmission between the H100 and the android Pad through socket, insert the pad directly into the socket of H100. Moreover, The recorder can realize user’s registration and user’s historical data records.
  • Page 11 www.ehealthcareinc.com info@ehealthcareinc.com 250 East Gish Road, San Jose CA, 95112 USA Homecare Multi-parameter Recorder Open the cover and insert the pad when you need to use the recorder) ( ②Accessories, pad storage box (Open the box cover and you can see : a:Spo2 sensor and cable b:Pad c:Adapter...
  • Page 12: Basic Operation

    Open the android pad support frame, insert the pad. Open the App 2.4 Instruction of App Power on H100 and APK will automatically run. Please connect the WIFI as required. After WIFI connected successfully, click NEXT to continue the operations. - 11 -...
  • Page 13 www.ehealthcareinc.com info@ehealthcareinc.com 250 East Gish Road, San Jose CA, 95112 USA Homecare Multi-parameter Recorder Follow the APK guide to insert the Pad into basement. And it will pair with the basement automatically. NOTE! Please use the same packaged Pad and Basement to be paired. - 12 -...
  • Page 14 www.ehealthcareinc.com info@ehealthcareinc.com 250 East Gish Road, San Jose CA, 95112 USA Homecare Multi-parameter Recorder The Prompt will be displayed and Click “Accept” to accept the Service Privacy Agreement. - 13 -...
  • Page 15 www.ehealthcareinc.com info@ehealthcareinc.com 250 East Gish Road, San Jose CA, 95112 USA Homecare Multi-parameter Recorder Now, we log in main interface. As the user account, we have three types. A. Visitor If you use Visitor to do the tests, the results will be not saved on Pad, you cannot find the history data interface.
  • Page 16 www.ehealthcareinc.com info@ehealthcareinc.com 250 East Gish Road, San Jose CA, 95112 USA Homecare Multi-parameter Recorder B. On-line User For On-line user, Click “User Management” option and click “on-line user” to register the on- line user. The accounts info should be supplied by your service team. - 15 -...
  • Page 17 www.ehealthcareinc.com info@ehealthcareinc.com 250 East Gish Road, San Jose CA, 95112 USA Homecare Multi-parameter Recorder C. Off-line User You can also register the off-line user, the test data can be saved on Pad but cannot be uploaded to the back-end platform. Click BP (Blood Pressure), SpO2 (Blood Oxygen), or ECG icon to start measurements.
  • Page 18 www.ehealthcareinc.com info@ehealthcareinc.com 250 East Gish Road, San Jose CA, 95112 USA Homecare Multi-parameter Recorder NOTE! You should select the correct account for testing! 2.4.1Blood Pressure Measurement Click the blood pressure icon and enter instruction for measurement, please operate according to instructions. - 17 -...
  • Page 19 www.ehealthcareinc.com info@ehealthcareinc.com 250 East Gish Road, San Jose CA, 95112 USA Homecare Multi-parameter Recorder When you make the cuff ready, click “start” and the recorder will start to measure twice automatically, you’re supposed to be calm and quiet when measuring. If you make fore to stop in the process, there are no measurement results.
  • Page 20 www.ehealthcareinc.com info@ehealthcareinc.com 250 East Gish Road, San Jose CA, 95112 USA Homecare Multi-parameter Recorder 2.3.2 SPO2 Measurement Click SPO2 icon and enter the instruction for measurement When you make your finger clap ready, You’re supposed to be calm and quiet and you can stop measurement in the process or wait for display result automatically in 30 seconds without click “Start”.
  • Page 21 www.ehealthcareinc.com info@ehealthcareinc.com 250 East Gish Road, San Jose CA, 95112 USA Homecare Multi-parameter Recorder 2.4.3 ECG Measurement Click “ECG” icon and enter the instruction for measurement When you make cable ready, you’re supposed to be calm and quiet and you can stop measurement in the process or wait for display result automatically in 2 minutes without click “Start”.
  • Page 22: Chapter 3 Ecg

    www.ehealthcareinc.com info@ehealthcareinc.com 250 East Gish Road, San Jose CA, 95112 USA Homecare Multi-parameter Recorder Chapter 3 ECG 3.1 Introduction Before mechanical systole, the heart firstly produces electrical excitement, which results in biological current, and conducts the current to the body surface through tissue and humor.
  • Page 23: Measurement Procedure

    www.ehealthcareinc.com info@ehealthcareinc.com 250 East Gish Road, San Jose CA, 95112 USA Homecare Multi-parameter Recorder 3.3 Measurement Procedure 3.3.1 Skin Preparation for Electrode Placement Good electrode-to-skin contact is important for a good ECG signal, as the skin is a poor conductor of electricity. It is necessary to deal with the skin properly before placing the electrodes.
  • Page 24: Ecg Display

    www.ehealthcareinc.com info@ehealthcareinc.com 250 East Gish Road, San Jose CA, 95112 USA Homecare Multi-parameter Recorder and should not be in parallel. 7.3.3 Connecting ECG Cable Plug the ECG cable into the ECG connector. An ECG waveform and numeric appears on the recorder display. 3.4 ECG Display The following figure shows the ECG display screen, the display on your Recorder may be looked slightly different.
  • Page 25: Chapter 4 Spo2

    www.ehealthcareinc.com info@ehealthcareinc.com 250 East Gish Road, San Jose CA, 95112 USA Homecare Multi-parameter Recorder Chapter 4 SpO2 4.1 Introduction The measurement of oxygen saturation of arterial blood (also known as pulse oxygen saturation, usually shortened as SpO ) adopts the principles of light spectra and volume tracing.
  • Page 26: Measurement Procedure

    www.ehealthcareinc.com info@ehealthcareinc.com 250 East Gish Road, San Jose CA, 95112 USA Homecare Multi-parameter Recorder patients; do not use damaged sensor or extension cable. Do not soak the sensor into water or make it wet, otherwise it may be damaged. ◼ When disposing the disposable SpO probe or useless SpO probe, please observe all local, state, and federal regulations that relate to the disposal of...
  • Page 27: Spo2 Display

    www.ehealthcareinc.com info@ehealthcareinc.com 250 East Gish Road, San Jose CA, 95112 USA Homecare Multi-parameter Recorder 4.4 SpO2 Display 4.4.1 Waveform Display 4.4.2 Parameter Display - 26 -...
  • Page 28: Chapter 5 Nibp

    www.ehealthcareinc.com info@ehealthcareinc.com 250 East Gish Road, San Jose CA, 95112 USA Homecare Multi-parameter Recorder Chapter 5 NIBP 5.1 Introduction The recorder uses the oscillometric method for measuring NIBP. The method of oscillometric indirectly estimates the systolic and diastolic pressures within the blood vessels by measuring the change of the pressure within blood pressure cuff along with the volume of the arteries and calculates the average pressure.
  • Page 29: Measurement Limitations

    www.ehealthcareinc.com info@ehealthcareinc.com 250 East Gish Road, San Jose CA, 95112 USA Homecare Multi-parameter Recorder 5.3 Measurement Limitations The measurement may be inaccurate or impossible: ——with excessive and continuous patient movement such as shivering or convulsions; ——if a regular arterial pressure pulse is hard to detect; ——with cardiac arrhythmias;...
  • Page 30 www.ehealthcareinc.com info@ehealthcareinc.com 250 East Gish Road, San Jose CA, 95112 USA Homecare Multi-parameter Recorder display screen, the display on your recorder may be looked slightly different. - 29 -...
  • Page 31: Chapter 6 Guidance And Manufacturer's Declaration Of Emc

    www.ehealthcareinc.com info@ehealthcareinc.com 250 East Gish Road, San Jose CA, 95112 USA Homecare Multi-parameter Recorder Chapter 6 Guidance and Manufacturer’s Declaration of Guidance and manufacturer’s declaration – electromagnetic emissions- for all EQUIPMENT and SYSTEMS Guidance and manufacture’s declaration – electromagnetic emission The recorder is intended for use in the electromagnetic environment specified below.
  • Page 32 www.ehealthcareinc.com info@ehealthcareinc.com 250 East Gish Road, San Jose CA, 95112 USA Homecare Multi-parameter Recorder Voltage dips, short <5% UT <5% UT Mains power quality should be interruptions (>95% dip in UT) (>95% dip in UT) that of a typical commercial or voltage variations on for 0.5 cycle for 0.5 cycle...
  • Page 33 www.ehealthcareinc.com info@ehealthcareinc.com 250 East Gish Road, San Jose CA, 95112 USA Homecare Multi-parameter Recorder Guidance and manufacturer’s declaration – electromagnetic immunity –for EQUIPMENT and SYSTEMS that are not LIFE-SUPPORTING Guidance and manufacture’s declaration – electromagnetic immunity The recorder is intended for use in the electromagnetic environment specified below. The customer or the user of recorder should assure that it is used in such an environment.
  • Page 34 www.ehealthcareinc.com info@ehealthcareinc.com 250 East Gish Road, San Jose CA, 95112 USA Homecare Multi-parameter Recorder theoretically with accuracy. To assess the electromagnetic environment due to fixed RF transmitters, an electromagnetic site survey should be considered. If the measured field strength in the location in which the recorder is used exceeds the applicable RF compliance level above, the recorder should be observed to verify normal operation.
  • Page 35: Chapter 7 Maintenance And Cleaning

    www.ehealthcareinc.com info@ehealthcareinc.com 250 East Gish Road, San Jose CA, 95112 USA Homecare Multi-parameter Recorder Chapter 7 Maintenance and Cleaning 7.1 Equipment Maintenance Warning: For optimal performance, product service should be performed only by qualified service personnel. Note: To ensure the performance and safety of equipment, it must be checked after using 1 year.
  • Page 36: Cleaning And Sterilizing Of Accessories

    www.ehealthcareinc.com info@ehealthcareinc.com 250 East Gish Road, San Jose CA, 95112 USA Homecare Multi-parameter Recorder 7.3 Cleaning and Sterilizing of Accessories ECG cable The recommended disinfectors include glutaric dialdehyde solution and 10% decolourant solution. a) Please clean cable prior to sterilization. b) Clean the cable surface with soft cloth bedewed with some fresh water or neutral soapy water.
  • Page 37 www.ehealthcareinc.com info@ehealthcareinc.com 250 East Gish Road, San Jose CA, 95112 USA Homecare Multi-parameter Recorder a) Please regularly clean the product; b) Remove cuff from connector and pull out airbag from sheath; c) Submerge clean and soft medical gauze pad or other soft cleaning tools into fresh water or neutral soapy water, and wring out surplus water from the submerged gauze then wipe airbag and pipe;...
  • Page 38: Chapter 8 Labeling And Language

    www.ehealthcareinc.com info@ehealthcareinc.com 250 East Gish Road, San Jose CA, 95112 USA Homecare Multi-parameter Recorder Chapter 8 Labeling and Language 8.1 Machine Label The sample of label only for reference. The label contents will be changed accordingly depends on manufacture side. 8.2 Language English is used to all the machines with the CE certificate, which includes the product document sent to the user-end、label、mark of package and software interface, etc..
  • Page 39: Chapter 9 Troubleshooting

    Problem Cause Solution Nothing happens when you press the The power is used up Charge the H100 pad “power on” button more than 3 seconds Measurement finishes An ECG wave-pattern could not be Check the user manual and repeat message “Signal...
  • Page 40 www.ehealthcareinc.com info@ehealthcareinc.com 250 East Gish Road, San Jose CA, 95112 USA Homecare Multi-parameter Recorder occur electromagnetic interference, or repeat measurement after change the environment. The measurement signal is too weak The disposable ECG electrodes are The disposable ECG electrode when measuring by lead wires. used again.
  • Page 41: Appendix A Specification

    www.ehealthcareinc.com info@ehealthcareinc.com 250 East Gish Road, San Jose CA, 95112 USA Homecare Multi-parameter Recorder Appendix A Specification A.1.Environmental Specifications +5℃ to +40℃ Operating temperature (IRMA AX+ sensor: +10℃ to +40℃ ISA OR+/AX+ sensor: +5℃ to +50℃) 15% to 85%(non condensing)6 Operating humidity Operating atmospheric 700hPa to 1060hPa...
  • Page 42: A.3.Measurement Specifications

    www.ehealthcareinc.com info@ehealthcareinc.com 250 East Gish Road, San Jose CA, 95112 USA Homecare Multi-parameter Recorder A.3.Measurement Specifications Lead type single lead Accuracy ±1%or±1bpm Resolution 1 bpm Signal Range 8 mV (vvp) Calibrating Signal 1mV(vvp),accuracy±5% Sensibility > 200 uV (vvp) Input Impedance >...
  • Page 43: Appendix B Product And Accessories List

    www.ehealthcareinc.com info@ehealthcareinc.com 250 East Gish Road, San Jose CA, 95112 USA Homecare Multi-parameter Recorder Appendix B Product and accessories List Name Instruction of Function Number Note Main frame Homecare Multi-parameter Recorder 7.85 inch Android PAD Monitor for data and result Important display (reusable lithium battery inside)
  • Page 44: Appendix C Abbreviations

    www.ehealthcareinc.com info@ehealthcareinc.com 250 East Gish Road, San Jose CA, 95112 USA Homecare Multi-parameter Recorder Appendix C Abbreviations abbr explanation abbr explanation abbr explanation µA microampere hertz millivolt µV microvolt inch milliwatt ampere kilo MΩ megaohm Ampere hour kilogram nanometer Beat per minute kPa kilopascal Breaths minute...

Table of Contents