Quick Links

ENFORCER
GREASE ENFORCER
Operation & Maintenance Manual
Mohegan Sun Casino • Uncasville, CT • 8/17
FOG
88888
88888
8888
8888 8888
88888
88888
8888
88888
88888
88888
88888
88888
Copyright ©2017 FOG Enforcer
Toll Free: 1-844-235-0369
E-mail: ajetheridgeco@embarqmail.com
Online: www.fogenforcer.com

Advertisement

Table of Contents
loading

Summary of Contents for FOG Enforcer GREASE ENFORCER

  • Page 1 ENFORCER GREASE ENFORCER Operation & Maintenance Manual Mohegan Sun Casino • Uncasville, CT • 8/17 88888 88888 8888 8888 8888 88888 88888 8888 88888 88888 88888 88888 88888 Copyright ©2017 FOG Enforcer Toll Free: 1-844-235-0369 E-mail: ajetheridgeco@embarqmail.com Online: www.fogenforcer.com...
  • Page 2 ENFORCER DESCRIPTION The Grease Enforcer was designed for those facilities that want to take charge of their pretreatment system to meet wastewater discharge limits, solid waste disposal requirements and reduce their risk of exposure to es- calating disposal costs. You can think of it as having a pumping truck permanently stationed on site providing daily disposal service, but with an environmentally “friendly”...
  • Page 3: System Specifications

    FOG Enforcer supplies a 3/4” female connector to connect to this supply. ©2017 FOG Enforcer All rights reserved • Patented/Patents Pending • Specifications subject to change without notice MNLGE 3 FOG Enforcer • 2014 Beeler Road • Wilson, NC 27893 • Phone (844) 235-0369...
  • Page 4: Operation Flow Chart

    7. The fats, oils and grease separate from the effluent in the FOG Enforcer The “cleaned” efflu-ent passes through the FOG Enforcer and is returned to the separator tank. 8. The motors & heaters in the FOG Enforcer activate, skimming the fats, oils & grease out and depositing them into a grease collection container.
  • Page 5 The Grease Enforcer is designed to operate with 230 volt three phase power. The system requires 30 amp rated fuses on the supply input. The system has individual internal fusing for each major component group.
  • Page 6: Timer Operation

    Tabs punched in indicate “ON” setting The FOG Enforcer Grease/Solids Timer System offers a great deal of flexibility to match the needs of your kitchen. This improved version incorporates dual 24-Hour Timers coupled with dual selector switches (one each for solids removal cycle and grease removal cycle). The selector switch provides three settings (heavy, medium and light) in order to best handle the grease and solids loading from your kitchen operation.
  • Page 7: Installation Schematic

    GREASE ENFORCER Installation Schematic ENFORCER CONTROL PANEL ©2017 FOG Enforcer All rights reserved • Patented/Patents Pending • Specifications subject to change without notice MNLGE 7 FOG Enforcer • 2014 Beeler Road • Wilson, NC 27893 • Phone (844) 235-0369...
  • Page 8: Side Views

    LINE GREASE/OILS COLLECTION CONTAINER SIDE VIEW COLLECTION SIDE ©2017 FOG Enforcer All rights reserved • Patented/Patents Pending • Specifications subject to change without notice MNLGE 8 FOG Enforcer • 2014 Beeler Road • Wilson, NC 27893 • Phone (844) 235-0369...
  • Page 9: Top View

    RETURN LINE FROM OUTLET OF REMOTE SEPARATOR TANK ©2017 FOG Enforcer All rights reserved • Patented/Patents Pending • Specifications subject to change without notice MNLGE 9 FOG Enforcer • 2014 Beeler Road • Wilson, NC 27893 • Phone (844) 235-0369...
  • Page 10 GREASE ENFORCER Solids Removal Operation ENFORCER ©2017 FOG Enforcer All rights reserved • Patented/Patents Pending • Specifications subject to change without notice MNLGE 10 FOG Enforcer • 2014 Beeler Road • Wilson, NC 27893 • Phone (844) 235-0369...
  • Page 11: Maintenance Instructions

    Inspect the grease outlet sump for build-up of congealed fats or fine solids. Wipe off any accumulation. QUARTERLY Grease the drive cam on each of the Grease Enforcer’s diaphragm lift pumps. There is a grease fitting on the drive cam’s housing. (Please see Page 26 “Grease Enforcer Diaphragm Pump Identification”) Check hose connections (quick disconnect) for tight fit.
  • Page 12 15 minutes, heater must be replaced ©2017 FOG Enforcer All rights reserved • Patented/Patents Pending • Specifications subject to change without notice MNLGE 12 FOG Enforcer • 2014 Beeler Road • Wilson, NC 27893 • Phone (844) 235-0369...
  • Page 13 ©2017 FOG Enforcer All rights reserved • Patented/Patents Pending • Specifications subject to change without notice MNLGE 13 FOG Enforcer • 2014 Beeler Road • Wilson, NC 27893 • Phone (844) 235-0369...
  • Page 14 GREASE ENFORCER Control Panel Wiring Diagram ENFORCER ©2017 FOG Enforcer All rights reserved • Patented/Patents Pending • Specifications subject to change without notice MNLGE 14 FOG Enforcer • 2014 Beeler Road • Wilson, NC 27893 • Phone (844) 235-0369...
  • Page 15 GREASE ENFORCER Grease Removal ENFORCER Component Wiring Diagram ©2017 FOG Enforcer All rights reserved • Patented/Patents Pending • Specifications subject to change without notice MNLGE 15 FOG Enforcer • 2014 Beeler Road • Wilson, NC 27893 • Phone (844) 235-0369...
  • Page 16 GREASE ENFORCER Coarse Solids Removal Wiring ENFORCER Diagram ©2017 FOG Enforcer All rights reserved • Patented/Patents Pending • Specifications subject to change without notice MNLGE 16 FOG Enforcer • 2014 Beeler Road • Wilson, NC 27893 • Phone (844) 235-0369...
  • Page 17 GROUND IN CONTROL PANEL 208-240 VAC LEAD FROM CONTROL PANEL ©2017 FOG Enforcer All rights reserved • Patented/Patents Pending • Specifications subject to change without notice MNLGE 17 FOG Enforcer • 2014 Beeler Road • Wilson, NC 27893 • Phone (844) 235-0369...
  • Page 18 GREASE ENFORCER Grease Timing Chart ENFORCER ©2017 FOG Enforcer All rights reserved • Patented/Patents Pending • Specifications subject to change without notice MNLGE 18 FOG Enforcer • 2014 Beeler Road • Wilson, NC 27893 • Phone (844) 235-0369...
  • Page 19 GREASE ENFORCER Grease Timing Chart ENFORCER ©2017 FOG Enforcer All rights reserved • Patented/Patents Pending • Specifications subject to change without notice MNLGE 19 FOG Enforcer • 2014 Beeler Road • Wilson, NC 27893 • Phone (844) 235-0369...
  • Page 20 GREASE ENFORCER Grease Timing Chart ENFORCER ©2017 FOG Enforcer All rights reserved • Patented/Patents Pending • Specifications subject to change without notice MNLGE 20 FOG Enforcer • 2014 Beeler Road • Wilson, NC 27893 • Phone (844) 235-0369...
  • Page 21 GREASE ENFORCER Solids Timing Chart ENFORCER ©2017 FOG Enforcer All rights reserved • Patented/Patents Pending • Specifications subject to change without notice MNLGE 21 FOG Enforcer • 2014 Beeler Road • Wilson, NC 27893 • Phone (844) 235-0369...
  • Page 22 GREASE ENFORCER Solids Timing Chart ENFORCER ©2017 FOG Enforcer All rights reserved • Patented/Patents Pending • Specifications subject to change without notice MNLGE 22 FOG Enforcer • 2014 Beeler Road • Wilson, NC 27893 • Phone (844) 235-0369...
  • Page 23 GREASE ENFORCER Solids Timing Chart ENFORCER ©2017 FOG Enforcer All rights reserved • Patented/Patents Pending • Specifications subject to change without notice MNLGE 23 FOG Enforcer • 2014 Beeler Road • Wilson, NC 27893 • Phone (844) 235-0369...
  • Page 24: Part Identification

    Part #WDS-1 (Wheel Sprocket) Part #PDA-1 (Skimming Wheel) ©2017 FOG Enforcer All rights reserved • Patented/Patents Pending • Specifications subject to change without notice MNLGE 24 FOG Enforcer • 2014 Beeler Road • Wilson, NC 27893 • Phone (844) 235-0369...
  • Page 25: Diaphragm Pump

    (To FOG Enforcer Separator Tank) Component) Pump Front ©2017 FOG Enforcer All rights reserved • Patented/Patents Pending • Specifications subject to change without notice MNLGE 25 FOG Enforcer • 2014 Beeler Road • Wilson, NC 27893 • Phone (844) 235-0369...
  • Page 26 Diaphragm (Order Part #DPK-1) Diaphragm Assembly Pump Front Pump Side ©2017 FOG Enforcer All rights reserved • Patented/Patents Pending • Specifications subject to change without notice MNLGE 26 FOG Enforcer • 2014 Beeler Road • Wilson, NC 27893 • Phone (844) 235-0369...
  • Page 27 PART #ʼs PHS-1032-112 & SSS-78 PUSH- BUTTON SWITCH SCREW & COLLAR (1) PLACE ©2017 FOG Enforcer All rights reserved • Patented/Patents Pending • Specifications subject to change without notice MNLGE 27 FOG Enforcer • 2014 Beeler Road • Wilson, NC 27893 • Phone (844) 235-0369...
  • Page 28 (3) PLACES #10-32 X 1/2” LONG SCREW (3 PLACES) ©2017 FOG Enforcer All rights reserved • Patented/Patents Pending • Specifications subject to change without notice MNLGE 28 FOG Enforcer • 2014 Beeler Road • Wilson, NC 27893 • Phone (844) 235-0369...
  • Page 29: Motor/Drive Assembly

    PART # WDS-1 WHEEL DRIVE SPROCKET (6 PLACES) ©2017 FOG Enforcer All rights reserved • Patented/Patents Pending • Specifications subject to change without notice MNLGE 29 FOG Enforcer • 2014 Beeler Road • Wilson, NC 27893 • Phone (844) 235-0369...
  • Page 30 Diaphragm Pump: Part # DP-1 Diaphragm Replacement Kit (Includes Diaphragm & Flapper Valves): Part # DPK-1 ©2017 FOG Enforcer All rights reserved • Patented/Patents Pending • Specifications subject to change without notice MNLGE 30 FOG Enforcer • 2014 Beeler Road • Wilson, NC 27893 • Phone (844) 235-0369...